• 제목/요약/키워드: Low temperature absorption

검색결과 482건 처리시간 0.025초

수도냉해의 발생기구와 그의 대책에 관한 연구 제1보 수도의 생장과 무기양분흡수에 미치는 온도의 영향 (Causes of Cold Damage of Rice Plant and Its Control 1. Effects of Temperature on the Growth and Absorption of Mineral Nutrients)

  • 임형빈
    • Journal of Plant Biology
    • /
    • 제17권4호
    • /
    • pp.31-37
    • /
    • 1974
  • Seedlings of Nongbaek representing strong cold tolerant variety of rice plant, Jinheung of medium variety and Tongil of weak variety were used respectively for the present study. These seedlings were water cultured in phytotron which maintained at the daytime and night temperature of 30-$25^{\circ}C$, 20-2$0^{\circ}C$, 20-15$^{\circ}C$ and 15-1$0^{\circ}C$. The growth rate of plant height, tillering rate, increase in dry weight and absorption pattern of important mineral nutrients at their early growth stage under each temperature conditions were observed. Generally, it appeared that Nongbaek was more active in the growth of plant height than Jinheung, and Jinheung was more active than Tongil under low temperature condition. The tillering rate of these three varieties was equally rapid while it was decreased in the order of weak cold tolerant variety, such as Tongil, Jinheung and Nongbaek as the temperature declined gradually. The dry weigh tincreasing curve showed almost the same pattern in the varieties at the treatment of each temperature. Under low temperature conditions, Nongbaek showed higher absorption rate of N per dry weight and higher absorption amount of per plant body, Jinheung followed and Tongil was the lowest. The absorption amount of P2O5 increased in the top part compared with the roots as temperature rose and decreased as temperature declined. There seemed to be no difference of absorption among the varieties which have different cold tolerance each other. Under low temperature the absorption rate of K per dry weight was high, as a whole, especially Nongbaek was markedly higher than the other two. The absorption rate of Ca, Mg and Fe was also equally high in all varieties under low temperature and Nongbaek showed a more absorptive tendency in the absorption amount under low temperature.

  • PDF

Sound Absorption Property of Heat-Treated Wood at A Low Temperature and Vacuum Conditions

  • Byeon, Hee-Seop;Park, Jung-Hwan;Hwang, Kyo-Kil;Park, Han-Min;Park, Beyung-Soo;Chong, Song-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권2호
    • /
    • pp.101-107
    • /
    • 2010
  • Heat treatment was performed to improve sound absorption properties for four tree species; Tulip tree, Korean Paulownia, Red pine and Costata birch, at temperature of $175^{\circ}C$ and $200^{\circ}C$under vacuum condition. Sound absorption properties of two kinds of boards, which were in radial and tangential sections, were measured under a frequency range of 100 to 3200 Hz by the two microphone transfer function method. It was found that sound absorption properties were increased by heat treatment and the efficiency was higher at $200^{\circ}C$ than that at $175^{\circ}C$. Even Costata birch had a little effect on low temperature of $175^{\circ}C$, $200^{\circ}C$ heat treatment for sound absorption property, the efficiencies of sound absorption were 14, 19%, respectively. The efficiencies of sound absorption ranged 22 to 120% for heat-treated Tulip tree, Korean Paulownia.

삼중효용 흡수사이클의 성능특성 평가 (evaluation of Performance Characteristic on Triple Effect Absorption Cycle)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.782-791
    • /
    • 1998
  • This paper presents a computer simulation of five types of triple effect absorption cycles employ-ing the refrigerant absorbent combinations of NH3/LiNO3 low-pressure type NH3/LiNO3+H2O/LiBr binary two-stage type series flow cycle and two types of parallel flow cycle for H2O/LiBr. The absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature approach temperature of absorber loss temperature of absorber and chilled water outlet temperature. The most important characteristic temperature of absorber and chilled water outlet temperature. The most important characteristic of NH3/LiNO3 low-pressure type and a NH3/LINO3+H2O/LiBr binary two-stage type is that it obtains a coefficient of performance higher than the sum of the performance coefficients of its part operating independently. As a result of this analysis the optimum designs and operating conditions were determined based on the operating conditions and the coefficient of performance.

  • PDF

금속수소화물 수소저장 용기 내부의 열 및 물질전달 현상에 대한 수치적 연구(I) - $LaNi_5$ 베드를 이용한 수소 흡장반응 해석 모델 개발 (Numerical analysis of the coupled heat and mass transfer phenomena in a metal hydride hydrogen storage reactor(I) - Model development of analyzation for hydrogen absorption reaction using the $LaNi_5$ bed)

  • 남진무;주현철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.225.1-225.1
    • /
    • 2010
  • Within recent years attention has been focused on the method of hydrogen storage using metal hydride reactor due to its high energy density, durability, safety and low operating pressure. In this paper, a numerical study is carried out to investigate the coupled heat and mass transfer process for absorption in a cylindrical metal hydride hydrogen storage reactor using a newly developed model. The simulation results demonstrate the evolution of temperature, equilibrium pressure, H/M atomic ratio and velocity distribution as time goes by. Initially, hydrogen is absorbed earlier from near the wall which sets the cooling boundary condition owing to that absorption process is exothermic reaction. Temperature increases rapidly in entire region at the beginning stage due to the initial low temperature and enough metal surface for hydrogen absorption. As time goes by, temperature decreases slowly from the wall region due to the better heat removal. Equilibrium pressure distribution appears similarly with temperature distribution for reasons of the function of temperature. This work provides a detailed insight into the mechanism and corresponding physicochemical phenomena in the reactor during the hydrogen absorption process.

  • PDF

가정용 흡수식 냉난방기 개발을 위한 재생기 성능실험 (Performance Experiment of Generator for Household Absorption Chiller and Heater)

  • 유선일;권오경;윤정인
    • 대한기계학회논문집B
    • /
    • 제23권10호
    • /
    • pp.1347-1354
    • /
    • 1999
  • Recently, the markets of the air conditioner are enlarging. The market size will reach 2.0 billion won in 2000. Electric heat pumps have been utilized as main residential air conditioners. especially in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes serious problem to the global environment such as global warming and ozone layer destruction. Absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the generator for absorption chiller and heater. Experiment was done with a high temperature generator, a low temperature generator, heat exchangers, a condenser and a solution tank. It was tested that the double effect series flow cycle with two kinds of solution cycle. Solution cycle B showed better than solution cycle A. Two kinds of heat exchanger were used, where one's heat transfer area is bigger than the other. Bigger one increased a little performance of absorption chiller and heater. But it was not economical. From this study, we got that the coefficient of performance(COP) is 0.82 and the capacity is 7.24 kW for an absorption chiller and heater.

수평원관상의 $LiBr-H_2O$ 흡수특성에 대한 연구 (Parametric Study on the $LiBr-H_2O$ Absorption Process on Horizontal Tubes)

  • 민준기;최도형
    • 한국전산유체공학회지
    • /
    • 제5권1호
    • /
    • pp.33-42
    • /
    • 2000
  • The LiBr-H₂O absorption process on a horizontal tube has been analyzed numerically. The flow field, which was calculated in the authors' previous study by solving the fully elliptic Navier-Stokes equations with accurate free-surface-tracking method, is used to solve the temperature and concentration distributions in the absorption film. With the assumption that the absorbent is linear, calculations have been made for various inlet temperature and flow-rate conditions. For low inlet temperature, the absorption rate is large in the upstream region but the mean temperature also increases and as a result the absorption decreases as the film flows to downstream while high-inlet-temperature case does the opposite. The difference in the absorption rate due to the inlet temperature change becomes smaller in the downstream than that in the upstream. For large flow rate, the heat transfer to the wall becomes poor due to the thick film and so does the absorption rate. The analyses have also been carried out for multiple tube arrangement and the results show that the absorption rate converges after a few tube rows.

  • PDF

저온 열원의 활용을 위한 흡수 발전/냉각 복합 사이클의 열적 해석 (Thermal Analysis of a Combined Absorption Cycle of Cogeneration of Power and Cooling for Use of Low Temperature Source)

  • 김경훈
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.413-420
    • /
    • 2011
  • Thermodynamic cycles using binary mixtures as working fluids offer a high potential for utilization of low-temperature heat sources. This paper presents a thermodynamic performance analysis of Goswami cycle which was recently suggested to produce power and cooling simultaneously and combines the Rankine cycle and absorption refrigeration cycle by using ammoniawater mixture as working fluid. Effects of the system parameters such as concentration of ammonia and turbine inlet pressure on the system are parametrically investigated. Results show that refrigeration capacity or thermal efficiency has an optimum value with respect to ammonia concentration as well as to turbine inlet pressure.

규칙충전물을 적용한 화학흡수법에 의한 이산화탄소 제거에 관한 연구 (A Study on CO2 Removal by Chemical Absorption Using Structured Packing)

  • 김재홍;김형호;김장호
    • 청정기술
    • /
    • 제9권1호
    • /
    • pp.43-48
    • /
    • 2003
  • As a result of study on factor affecting absorption efficiency using the structured packing, Mellapak N. 250Y for the chemical absorption of $CO_2$ that cause global warming due to development of industry, it is shown that Mellapak N. 250Y has lower pressure drop and superior efficiency of mass transfer than 25mm Pall ring. Also, in the absorption process, it produces high efficiency in the increase of load and concentration of absorption liquid and produces low efficiency in the increase of temperature. In the effect of overall mass transfer coefficient for 15% MEA on the temperature variation of absorbent, when absorbent temperature for 15% MEA varied as 25, 50, $80^{\circ}C$, overall mass transfer coefficients were shown as 0.83, 1.00, $0.90kmol/m^3-h-kPa$.

  • PDF

A Theoretical Study on the Low Transition Temperature of VO2 Metamaterials in the THz Regime

  • Kyoung, Jisoo
    • Current Optics and Photonics
    • /
    • 제6권6호
    • /
    • pp.583-589
    • /
    • 2022
  • Vanadium dioxide (VO2) is a well-known material that undergoes insulator-to-metal phase transition near room temperature. Since the conductivity of VO2 changes several orders of magnitude in the terahertz (THz) spectral range during the phase transition, VO2-based active metamaterials have been extensively studied. Experimentally, it is reported that the metal nanostructures on the VO2 thin film lowers the critical temperature significantly compared to the bare film. Here, we theoretically studied such early transition phenomena by developing an analytical model. Unlike experimental work that only measures transmission, we calculate the reflection and absorption and demonstrate that the role of absorption is quite different for bare and patterned samples; the absorption gradually increases for bare film during the phase transition, while an absorption peak is observed at the critical temperature for the metamaterials. In addition, we also discuss the gap width and VO2 thickness effects on the transition temperatures.

수평 냉각관 외부를 흘러내리는 $LiBr-H_2O$ 수용액의 유동 및 열/물질 전달 특성에 관한 실험적 연구 (An Experimental Study on Flow and Heat / Mass Transfer Characteristics of $LiBr-H_2O$ Solution Flowing over a Cooled Horizontal Tube)

  • 설신수;이상용
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1085-1096
    • /
    • 2000
  • An experimental study was performed to examine the heat and mass transfer characteristics of $LiBr-H_2O$ solution flowing over a single horizontal tube with the water vapor absorption. Effects of the flow rate and the temperature of the solution at the top of the tube, the absorber pressure and the drainage pattern were considered. The absorption rate depends highly on the absorber pressure at the low flow rate condition while on the solution inlet temperature at the high flow rate condition. Also, when the flow rate is low, the absorption performance with the sheet flow drainage appeared to be higher than that with the dripping/jet drainage. However, at the high flow rate condition, the case became reversed. The liquid film became wavy with the higher absorption rate. The waves were more probable to form with the lower flow rate and temperature of the solution, and with the higher absorber pressure.