• 제목/요약/키워드: Low resistance

검색결과 4,962건 처리시간 0.034초

Alternative Therapies with Tacrolimus and Low-Dose Doxycycline for Oral Chronic Graft-versus-Host Disease That Is Resistant to Topical Corticosteroid Medication: Case Report

  • Ju, Hye-Min;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • 제43권1호
    • /
    • pp.16-20
    • /
    • 2018
  • Graft-versus-host disease (GVHD) is frequent complications of hematopoietic stem cell transplantation. In the chronic GVHD (cGVHD), the oral cavity is the most commonly affected region. The clinical manifestations include erythema, ulceration, lichenoid-hyperkeratotic change in oral mucosa, dry mouth, and limitation of mouth opening. The initial treatment strategy of oral cGVHD patients is topical corticosteroid therapy in various formulation. However, corticosteroid resistance appears in some patients. We report a case of a 25-year-old male patient with oral cGVHD, who has resistance to topical corticosteroid medication, treated with 0.03% tacrolimus ointment and low-dose doxycycline. The patient showed subjective and objective improvement without side effect.

비휘발성 기억소자의 저항효과에 관한 연구 (A study on the impedance effect of nonvolatile memory devices)

  • 강창수
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권5호
    • /
    • pp.626-632
    • /
    • 1995
  • In this paper, The effect of the impedances in SNOSFET's memory devices has been developed. The effect of source and drain impedances measured by means of two bias resistances - field effect bias resistance by inner region, external bias resistance. The effect of the impedances by source and drain resistance shows the dependence of the function of voltages applied to the gate. It shows the differences of change in source drain voltage by means of low conductance state and high conductance state. It shows the delay of threshold voltages. The delay time of low conductance state and high conductance state by the impedances effect shows 3[.mu.sec] and 1[.mu.sec] respectively.

  • PDF

저온소성 기판과 Cu와의 동시소성에 미치는 CuO의 첨가효과 (The Influence of CuO on Bonding Behaviors of Low-Firing-Substrate and Cu Conductor)

  • 박정현;이상진
    • 한국세라믹학회지
    • /
    • 제31권4호
    • /
    • pp.381-388
    • /
    • 1994
  • A new process which co-fires the low-firing-substrate and copper conductor was studied to achieve good bond strength and low sheet resistance of conductor. Cupric oxide is used as the precursor of conductive material in the new method and the firing atmosphere of the new process is changed sequently in air H2N2. The addition of cupric oxide and variations of firing atmosphere permited complete binder-burnout in comparison with the conventional method and contributed to the improvement of resistance and bonding behaviors. The potimum conditions of this experiment to obtain the satisfactory resistance and bond strength are as follows (binder-burnout temperature in air; 55$0^{\circ}C$, reducing temperature in H2; 40$0^{\circ}C$ for 30 min, ratio of copper and cupric oxide; 60:40~30:70 wt%). The bonding mechanism between the substrate and metal was explained by metal diffusion layer in the interface and the bond strength mainly depended on the stress caused by the difference of shrinkage and thermal expansion coefficient between the substrate and metal.

  • PDF

프릿트 첨가에 따른 저온소성 기판과 Cu와의 접합 거동에 관한 연구 (The Effect of Frit on Bonding Behavior of Low-firing-substate and Cu Conductor)

  • 박정현;이상진
    • 한국세라믹학회지
    • /
    • 제32권5호
    • /
    • pp.601-607
    • /
    • 1995
  • The bond strength between the low-firing-substrate and Cu conductor depended on the softening point and the amount of frit added to the metal paste. The addition of 3 wt% frit (softening point: 68$0^{\circ}C$) to the metal paste resulted in the improvement of bond strength, which was approximately 3 times higher (3kg/$\textrm{mm}^2$) than that of non frit condition. It was also found that fracture surface shifted to the ceramic substrate in the interface region. These phenomena were attributed to the frit migration into the metal-ceramic interface. It was thought that the migration of glass frit occurred extensively when the softening point of glass firt was 68$0^{\circ}C$. The sheet resistance of Cu conductor remained constant by the addition of 4 wt% frit regardless of softening point of frit. For all samples with more than 4 wt% frit, the sheet resistance increased abruptly.

  • PDF

산업용 저항 온도계의 저온 자동 비교 교정 시스템 개발 (Development of the automatic calibration system for industrial resistance thermometers at low temperatures)

  • 양인석;송창호;강기훈;김용규
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.429-436
    • /
    • 2008
  • A system is designed and fabricated for the automatic low temperature calibration by comparison of industrial resistance thermometers. The cryostat is suitable for the calibration of four capsule type thermometers and four long stem thermometers. By the automatic temperature control of the cryostat, we could calibrate thermometers from $-200^{\circ}C$ to $0^{\circ}C$ for ${\sim}15$ hours by one fill of liquid nitrogen in the test run of the system. The uncertainty of the calibration for industrial platinum resistance thermometers using the automatic system is about 30mK with a 95.% confidence interval.

저온소결 PMN-PNN-PZT 세라믹스를 이용한 고출력 강압용 적층 압전변압기의 전기적 특성 (Electrical Properties of High Power Step Down Multilayer Piezoelectric Transformer using Low Temperature Sintering PMN-PNN-PZT Ceramics)

  • 류주현;김국진;백동수;윤현상
    • 한국전기전자재료학회논문지
    • /
    • 제20권4호
    • /
    • pp.332-336
    • /
    • 2007
  • In this study, multilayer piezoelectric transformer was manufactured using the PMN-PNN-PZT ceramic and then the electrical characteristics were investigated according to the variations of frequency and load resistance. The voltage step-up ratio of multilayer piezoelectric transformer showed the maximum value at the vicinity of 75 kHz and increased according to the increase of load resistance. When the output impedance coincided with the load resistance, the multilayer piezoelectric transformer showed the temperature rise of less than $20^{\circ}C$ at the output power of 20 W. As the results, the multilayer piezoelectric transformer manufactured at low co-firing temperature of $940^{\circ}C$ using PMN-PNN-PZT ceramics could be stably driven as the step-down transformers.

Investigated properties of Low temperature curing Ag Paste for Silicon Hetero-junction Solar Cell

  • Oh, Donghyun;Jeon, Minhan;Kang, Jiwoon;Shim, Gyeongbae;Park, Cheolmin;Lee, Youngseok;Kim, Hyunhoo;Yi, Junsin
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.160-160
    • /
    • 2016
  • In this study, we applied the low temperature curing Ag paste to replace PVD System. The electrode formation of low temperature curing Ag paste for silicon Hetero-junction solar cells is important for improving device characteristics such as adhesion, contact resistance, fill factor and conversion efficiency. The low temperature curing Ag paste is composed various additives such as solvent, various organic materials, polymer, and binder. it depends on the curing temperature conditions. The adhesion of the low temperature curing Ag paste was decided by scratch test. The specific contact resistance was measured using the transmission line method. All of the Ag electrodes were experimented at various curing temperatures within the temperature range of $160^{\circ}C-240^{\circ}C$, at $20^{\circ}C$ intervals. The curing time was also changed by varying the conditions of 10-50min. In the optimum curing temperature $200^{\circ}C$ and for 20 min, the measured contact resistance is $19.61m{\Omega}cm^2$. Over temperature $240^{\circ}C$, confirmed bad contact characteristic. We obtained photovoltaic parameter of the industrial size such as Fill Factor (FF), current density (Jsc), open-circuit voltage (Voc) and convert efficiency of up to 76.2%, 38.1 mA/cm2, 646 mV and 18.3%, respectively.

  • PDF

Treatment results of the second-line chemotherapy regimen for patients with low-risk gestational trophoblastic neoplasia treated with 5-day methotrexate and 5-day etoposide

  • Kanno, Toshiyuki;Matsui, Hideo;Akizawa, Yoshika;Usui, Hirokazu;Shozu, Makio
    • Journal of Gynecologic Oncology
    • /
    • 제29권6호
    • /
    • pp.89.1-89.8
    • /
    • 2018
  • Objective: Highly effective chemotherapy for patients with low-risk gestational trophoblastic neoplasia (GTN) is associated with almost a 100% cure rate. However, 20%-30% of patients treated with chemotherapy need to change their regimens due to severe adverse events (SAEs) or drug resistance. We examined the treatment outcomes of second-line chemotherapy for patients with low-risk GTN. Methods: Between 1980 and 2015, 281 patients with low-risk GTN were treated. Of these 281 patients, 178 patients were primarily treated with 5-day intramuscular methotrexate (MTX; n=114) or 5-day drip infusion etoposide (ETP; n=64). We examined the remission rates, the drug change rates, and the outcomes of second-line chemotherapy. Results: The primary remission rates and drug resistant rates of 5-day ETP were significantly higher (p<0.001) and significantly lower (p=0.002) than those of 5-day MTX, respectively. Forty-seven patients (26.4%) required a change in their chemotherapy regimen due to the SAEs (n=16) and drug resistance (n=31), respectively. Of these 47 patients failed the first-line regimen, 39 patients (39/47, 82.9%) were re-treated with single-agent chemotherapy, and 35 patients (35/39, 89.7%) achieved remission. Four patients failed second-line, single-agent chemotherapy and eight patients (17.0%) who failed first-line regimens were treated with combined or multi-agent chemotherapy and achieved remission. Conclusions: Patients with low-risk GTN were usually treated with single-agent chemotherapy, while 20%-30% patients had to change their chemotherapy regimen due to SAEs or drug resistance. The second-line regimens of single-agent chemotherapy were effective; however, there were several patients who needed multiple agents and combined chemotherapy to achieve remission.

생체전기자율반응 측정기를 이용한 조기난소부전증 환자의 피부저항변이도 연구 (1, 2, 3 상한 중심으로) (A Study of Skin Resistance Variability of POF Patients by Autonomic Bioelectric Response Recorder (Centering around 1-3 Parts))

  • 최은미;강명자;위효선
    • 대한한방부인과학회지
    • /
    • 제19권3호
    • /
    • pp.247-256
    • /
    • 2006
  • Purpose : To research the Skin Resistance Variability(SRV) of premature ovarian failure(POF) patients by Autonomic Bioelectric Response Recorder(ABR-2000 system, Meridian, Korea) and report the specific results in SRV of POF patients. Methods : We measured SRV of 17 POF Patients who came to Conmaul Oriental Medical Hospital during August 2005 ${\sim}$ July 2006 by ABR-2000 system. We analyzed the results which height of graph Part was converted into 0${\sim}$10, and the readings of Low/Normal/High. Results : The mean value of graph height on each(1, 2, 3) part is lower than normal range(4-6) in POF patients. The distribution ratio of Low/Normal/High on each(1, 2, 3) part shows that there are much more Low proportion in POF patients. Conclusion : The low graph height of POF patients on 1, 2, 3 part means that conductivity & capacitance of POF patients is low, especially on head.

  • PDF

Mechanical Properties and Microstructures in WC-12%Co/Low Carbon Steel Metal Matrix Composites(MMC) Welding Overlay

  • 임희식;김태형;박경채
    • Journal of Welding and Joining
    • /
    • 제21권2호
    • /
    • pp.50-56
    • /
    • 2003
  • Metal matrix composites(MMC) consist of metal matrix into which is distributed a second solid phase. The normal intension is to develop a material with superior mechanical properties (for example increased toughness, stiffness and wear resistance) compared to those inherent in the matrix component. In this study, WC-12%Co/low carbon steel MMC overlays have been prepared by Gas Metal Arc Welding(GMAW) according to feeding rate of WC-12%Co grit. The macro and microstructures were examined using optical microscopy (OM) and scanning electron microscopy(SEM) each other. The characteristics of hardness and wear resistance have been investigated. WC-12%Co/low carbon steel MMC overlays which have been taken good beads without porosity and cracks were manufactured by method of GMAW. Matrix of overlayed surface was seen as fish bone and faceted dendrite structures. It was known that structures were iron tungsten carbides, Fe$_{6}$W$_{6}$C which have been occurred by melting of WC-12%Co grits. After MMC had been tested by block-roll wear test it was known that WC-12%Co/low carbon steel MMC has a excellent wear resistance by exiting Fe6w6c and WC-12%Co grit. The consequence was that region of overlay with Fe$_{6}$W$_{6}$C phase has been showed a model of adhesive wear, but region of overlay with WC-12%Co grit was restrained as a result of mechanism that wear of WC-12%Co grit is not adhesive but fracture.racture.