• Title/Summary/Keyword: Low radiation

Search Result 2,589, Processing Time 0.034 seconds

Analysis of Cooling Effect on the Plastic Film Cover of Greenhouse Module Depending on the Shade and Water Curtain (온실지붕 차광과 수막 수준에 따른 냉방효과 분석)

  • Kim, Young-Bok;Park, Joong-Chun;Lee, Seung-Kyu;Kim, Sung-Tae;La, Woo-Jung;Huh, Moo-Ryong;Jeong, Sung-Woo
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.306-316
    • /
    • 2006
  • In this study, the effect of the shade level, water flow rate applied to the shades and the temperature of water on the greenhouse cooling was investigated depending on the shade level of 0, 35, 55, 75%, and water flow rate and water temperature by the test on the small wooden frames to find out the low cost cooling method. With increasing of the dry bulb temperature of outside air, the dry bulb temperature in the wooden frames increased. For the frames with the shade and water, inside temperatures of the frames were lower of -0.2$\sim$-1.2$^{\circ}C$ than the temperature of the outside air and higher than the water temperature. For the frames without water, inside temperatures of the frames were higher of 1.7$\sim$4$^{\circ}C$ than the outside and not affected by the shade level very much. The water flow rate and the temperature of the water were not the important factors to decrease the inside temperatures in the frames. The black globe temperature became lower with increasing of shade level. The shade frames with water curtain showed the best cooling effect because of reducing thermal radiation and cooling the plastic film cover. The surface temperatures of the plastic film cover for the water supplied modules became lower with increasing of the shade level. The relative humidity was decreased with the dry bulb temperature in the frame increasing and not affected by the dry bulb temperature of the outside air for the frames with the shade and water.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF

Current Status and Future Perspective of PET (PET 이용 현황 및 전망)

  • Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) defecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3,015 and 4,414 in 1996,1997,1998,1999 and 2000, respectively. The application in cardiac disorders is minimal, and among various neuropsychiatric diseases, patients with epilepsy or dementia can benefit from PET studios. Recently, we investigated brain mapping and neuroreceptor works. PET is not a key application for evaluation of the cardiac patients in Korea because of the relatively low incidence of cardiac disease and less costly procedures such as SPECT can now be performed. The changes in the application of PET studios indicate that, initially, brain PET occupied almost 60% in 1995, followed by a gradual decrease in brain application. However, overall PET use in the diagnosis and management of patients with cancer was up to 63% in 2000. The current medicare coverage policy in the USA is very important because reimbursement policy is critical for the promotion of PET. In May 1995, the Health Care Financing Administration (HCFA) began covering the PET perfusion study using Rubidium-82, evaluation of a solitary pulmonary nodule and pathologically proven non-small cell lung cancer. As of July 1999, Medicare's coverage policy expanded to include additional indications: evaluation of recurrent colorectal cancer with a rising CEA level, staging of lymphoma and detection of recurrent or metastatic melanoma. In December of 2001, National Coverage decided to expand Medicare reimbursement for broad use in 6 cancers: lung, colorecctal, lymphoma, melanoma, head and neck, and esophageal cancers; for determining revascularization in heart diseases; and for identifying epilepsy patients. In addition, PET coverage is expected to further expand to diseases affecting women, such as breast, ovarian, uterine and vaginal cancers as well as diseases like prostate cancer and Alzheimer's disease.

Comparison of Perception Differences About Nuclear Energy in 4 East Asian Country Students: Aiming at $10^{th}$ Grade Students who Participated in Scientific Camps, from Four East Asian Countries: Korea, Japan, Taiwan, and Singapore (동아시아 4개국 학생들의 핵에너지에 대한 인식 비교: 과학캠프에 참가한 한국, 일본, 대만, 싱가포르 10학년 학생들을 대상으로)

  • Lee, Hyeong-Jae;Park, Sang-Tae
    • Journal of The Korean Association For Science Education
    • /
    • v.32 no.4
    • /
    • pp.775-788
    • /
    • 2012
  • This study was done at a scientific camp sponsored by Nara Women's University Secondary School, Japan. In this school, $10^{th}$ grade students from 4 East Asian countries: Korea, Japan, Taiwan, and Singapore, participated. We made a research on students' perceptions about nuclear energy. Sample populations include 77 students in total, with 12 Korean, 46 Japanese, 9 Taiwanese and 10 Singaporean students. Overall perceptions comparison about nuclear energy shows average values from the order of highest Korea, Taiwan, Singapore, and to lowest, Japan. We implemented a T-test to identify perception differences about nuclear energy, with one group that include 3 countries (Korea, Taiwan and Singapore) and another group that includes all the Japanese students. T-test results of perceptions about nuclear energy shows students from the 3 countries of Korea, Taiwan and Singapore having higher average than Japanese students. (p<.05). Korean average scores regarding overall perceptions about nuclear energy show as the highest in all 4 East Asian countries and also highest in all subcategories. On the contrary in Japan, they have lower and negative perceptions of nuclear energy. In spite of these facts, perceptions of Japanese students about nuclear energy seem lowest and negative mainly because of the recent Fukushima nuclear power plant disaster, caused by the tsunami and its subsequent damages and fears of radiation leaks, etc. This shows that negative information about future disasters and its resulting damages like the Chernobyl nuclear accident could influence more on people's risk perception than general information like nuclear energy-related technologies or the news that the plant is operating normally, etc. Even if the possibility of this kind of accident is very low, just one accident could bring abnormal risks to technology itself. This strong signal makes negative image and strengthens its perceptions to the people. This could bring a stigma about nuclear energy. This study shows that Government's policy about the highest priority for nuclear energy safety is most important. As long as such perception and decision are fixed, we found that it might not be easy to get changed again because they were already fortified and maintained.

Preoperative Evaluation of Brain Lesion with $^{201}Tl$ Brain SPECT: Is It Useful to Differentiate Benign and Malignant Lesions? (수술 전 뇌 병변의 $^{201}Tl$ 뇌 SPECT: 양성과 악성 병변을 감별하는데 유용한가?)

  • Sohn, Hyung-Sun;Kim, Euy-Neyng;Kim, Sung-Hoon;Chung, Yong-An;Chung, Soo-Kyo;Bong, Yong-Gil;Lee, Youn-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.371-380
    • /
    • 2000
  • Purpose: Thallim-201 ($^{201}Tl$) brain SPECT, which can represent cellular activity of brain lesions, may provide more useful information in differentiating between benign and malignant brain lesions more so than CT of MRI, that merely represents anatomic changes or breakdown of blood brain barrier. We used $^{201}Tl$ brain SPECT prospectively to evaluate the utility of $^{201}Tl$-indices as an indicator of benign or malig nant lesions. Materials and Methods: We studied 28 patients. There were 13 cases of benign lesions (3: nonspecific benign lesion, 3: meningioma, 2: low grade glioma, 1: tuberculoma, central neurocytoma, hemangioblastoma, radiation necrosis, and choroid plexus papilloma) and 15 cases of malignant lesions (6: glioblastoma multiforme, 5: anaplastic glioma, 2: medulloblastoma, 1: metastasis and lymphoma). In all patients, CT and/or MRI were obtained and then $^{201}Tl$ brain SPECT was obtained with measuring mean $^{201}Tl$ index and peak $^{201}Tl$ index. An unpaired t-test was performed to compare the $^{201}Tl$-indices and pathologic diagnoses to evaluate the utility of $^{201}Tl$-indices as all indicator of benign or malignant lesions. Results: There were no statistically significant difference in $^{201}Tl$-indices between benign and malignant brain lesion (p>0.05). Conclusion: These results demonstrated that we could not use $^{201}Tl$ indices on brain SPECT alone as an indicator of benign or malignant brain lesions.

  • PDF

The Contribution of Innovation Activity to the Output Growth of Emerging Economies: The Case of Kazakhstan

  • Smagulova, Sholpan;Mukasheva, Saltanat
    • Journal of Distribution Science
    • /
    • v.10 no.7
    • /
    • pp.33-41
    • /
    • 2012
  • The purpose of this study is to analyse the state of the energy industry and to determine the efficiency of its functioning on the basis of energy conservation principle and application of innovative technologies aimed at improving the ecological modernisation of agricultural sectors of Kazakhstan. The research methodology is based on an integrated approach of financial and economic evaluation of the effectiveness of the investment project, based on calculation of elasticity, total costs and profitability, as well as on comparative, graphical and system analysis. The current stage is characterised by widely spread restructuring processes of electric power industry in many countries through introduction of new technical installations of energy facilities and increased government regulation in order to enhance the competitive advantage of electricity market. Electric power industry features a considerable value of creating areas. For example, by providing scientific and technical progress, it crucially affects not only the development but also the territorial organisation of productive forces, first of all the industry. In modern life, more than 90% of electricity and heat is obtained by Kazakhstan's economy by consuming non-renewable energy resources: different types of coal, oil shale, oil, natural gas and peat. Therefore, it is significant to ensure energy security, as the country faces a rapid fall back to mono-gas structure of fuel and energy balance. However, energy resources in Kazakhstan are spread very unevenly. Its main supplies are concentrated in northern and central parts of the republic, and the majority of consumers of electrical power live in the southern and western areas of the country. However, energy plays an important role in the economy of industrial production and to a large extent determines the level of competitive advantage, which is a promising condition for implementation of energy-saving and environmentally friendly technologies. In these circumstances, issues of modernisation and reforms of this sector in Kazakhstan gain more and more importance, which can be seen in the example of economically sustainable solutions of a large local monopoly company, significant savings in capital investment and efficiency of implementation of an investment project. A major disadvantage of development of electricity distribution companies is the prevalence of very high moral and physical amortisation of equipment, reaching almost 70-80%, which significantly increases the operating costs. For example, while an investment of 12 billion tenge was planned in 2009 in this branch, in 2012 it is planned to invest more than 17 billion. Obviously, despite the absolute increase, the rate of investment is still quite low, as the total demand in this area is at least more than 250 billion tenge. In addition, industrial infrastructure, including the objects of Kazakhstan electric power industry, have a tangible adverse impact on the environment. Thus, since there is a large number of various power projects that are sources of electromagnetic radiation, the environment is deteriorated. Hence, there is a need to optimise the efficiency of the organisation and management of production activities of energy companies, to create and implement new technologies, to ensure safe production and provide solutions to various environmental aspects. These are key strategic factors to ensure success of the modern energy sector of Kazakhstan. The contribution of authors in developing the scope of this subject is explained by the fact that there was not enough research in the energy sector, especially in the view of ecological modernisation. This work differs from similar works in Kazakhstan in the way that the proposed method of investment project calculation takes into account the time factor, which compares the current and future value of profit from the implementation of innovative equipment that helps to bring it to actual practise. The feasibility of writing this article lies in the need of forming a public policy in the industrial sector, including optimising the structure of energy disbursing rate, which complies with the terms of future modernised development of the domestic energy sector.

  • PDF

Long-Term Observation of Temperature in the Coastal Waters Adjacent to the Wolsung Nuclear Power Plant (월성 원자력 발전소 주변 해역의 장기간 수온관측)

  • Chung, Jong-Yul;Kang, Hyoun-Woo;Shin, Young-Jae;Kim, Kye-Young;Jun, Ho-Kyung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.4
    • /
    • pp.183-192
    • /
    • 1998
  • The long-term observation of temperature in the coastal waters adjacent to the Wolsung Nuclear Power Plant has been carried out from November 10, 1996 to August 22, 1997, for approximately 280 days using a real-time temperature measurement buoy system. The sea-surface temperature was measured at every 10 minute using 10 buoys. The vertical structure of temperature was investigated near the outlet of the plant with two thermistor chains equipped with 10 sensors at 1 m interval The monthly averaged temperature was the lowest with spatial average of $12.8^{\circ}C$ in February and was the highest in August with spatial average of $19.6^{\circ}C$. The extremely low temperature was frequently observed between June and August, which seems to be the consequence of the intrusion of cold water near the southeastern coast of Korea. Distributions of the daily and hourly averaged temperature show that the highest temperature always occurred near the outlet of the plant and the warm-water patch moved along the north-south direction with the semidiurnal period. The semidiurnal fluctuation of temperature was also observed near the surface of the vertical profiles. The spectral analysis of temperature between February and April 1997 shows that the semidiurnal components prevailed near the outlet. It is likely that the semidiurnal components were due to the prevailing semidiurnal tide in this region. In August 1997, the diurnal components were dominant at the surface water of all stations except Station 12, which suggests that the warm water from the outlet of the plant has less effects in summer on the surrounding waters than the strong solar radiation.

  • PDF

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

A Study of Injection Dose for Patients and Exposure Dose for Technologists from the PET/CT Systems (PET/CT 장비 특성에 따른 방사성 의약품 주입량이 방사선 종사자에게 미치는 영향)

  • Park, Hoon-Hee;Oh, Ki-Beak;Lee, Seung-Jae;Bhan, Young-Kag;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Purpose: It appears the different value when the injection dose is calculating for patients on each PET/CT systems. It directly affects the technologists' radiation exposed dose. We studied the effect of the variable injection doses from several PET/CT systems to exposure dose for technologists. Materials and Methods: Six technologists have worked for 5 months through unit rotations with 3 PET/CT systems {Scanner 1 (S1): 0.15 mCi/kg, Scanner 2 (S2): 0.17 mCi/kg, Scanner 3 (S3): 0.12 mCi/kg}. Eighteen to 19 patients have had examinations per a day on each PET/CT systems. Examination parameters were adjusted to the same. TLDs were used for checking the exposure dose of technologists. Results: Each technologists' the monthly average exposure dose was as follows; S1: 0.76 mSv, S2: 0.93 mSv, S3: 0.47 mSv. The maximum exposure dose was 1.12 mSv, and minimum was 0.42 mSv. The results showed significance in the correlation between the PET/CT system and the exposure dose (p<0.005). Conclusion: When the amount of injection dose was small, the exposure dose was decreased not only the patients but also the technologists. The exposure dose was decreased by the individual proficiency of technologists. However, the low injection dose can highly reduce the exposure dose for technologist so that there will be needed to following studies.

  • PDF

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF