• Title/Summary/Keyword: Low pressure hose

Search Result 12, Processing Time 0.025 seconds

A Study on Swaging Characteristics of Band for Low Pressure Hose (저압 호스용 밴드의 체결특성에 관한 연구)

  • Kim Tyoung-Gyu;Kim Pil-Jong;Cho Seok-Beom;Kwon Boo-Kil
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.3 s.28
    • /
    • pp.32-37
    • /
    • 2005
  • Hose bands, which are used in LPG (Liquefied Petroleum Gas) or LNG (Liquefied Natural Gas) facilities for home use to join low pressure hoses with fuse-cocks (or regulators), should give a tight connection to prevent a gas leakage from hose connection parts. In this paper, hydraulic pressure tests and pull force tests were carried out to evaluate the performance and swaging length of hose bands. Experimental results showed that the swaging force of ear type bands were higher than those of spring bands and also showed that the optimal swaging length was about 1${\~}$2 mm from the hose end.

  • PDF

Finite Element Analysis of Power Steering Hose Subject to Internal Pressure (내압을 받는 파워스티어링 호스의 유한요소해석)

  • Cho, Jin-Rae;Jeon, Do-Hyung;Roh, Gi-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.2
    • /
    • pp.181-188
    • /
    • 2004
  • The objective of this paper is to numerically examine the mechanical behavior of the swaged power steering(PS) hose subject to internal pressure. PS hose experiences a large internal pressure change in operating, so it's material part has to resist a cyclic expansion and compression without causing oil leakage. This cyclic pressure is intimately associated with fatigue failure of PS hose. In this study, we compare two types of PS hose. The numerical investigation is composed of three steps; swaging analysis, low and high pressure analyses. The comparative numerical results provide the basic data for the optimal PS design.

Life Prediction for High Pressure Hose of Power Steering System by Impulse Pressure Test (충격 압력을 받는 파워스티어링 시스템의 고압호스 수명 예측)

  • Lee, Gi-Chun;Kim, Hyoung-Eui;Park, Jong-Won;Lee, Jong-Hwang;Jeong, Won-Wook;Im, Young-Han;Hwang, Kwon-Tae;Lee, Young-Shin;Kim, Jae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • The hydraulic hose can be divided with the low pressure, the medium pressure, and the high pressure hose according to the applied pressure. The power steering system in a passenger car can be divided with the high pressure and the low pressure hose. This study deals with the life prediction for high pressure hose to be given impulse pressure which was generated in turning the car. To adjust with external and internal condition, impulse pressure and oil temperature need to be controlled with impulse test system. The result, which is only controlled with the pressure and oil temperature, adapted Calibrated Accelerated Life Test(CALT) method to predict the life of the high pressure hose and analyzed the swagging part by finite element method during the impulse test.

Analysis of Foot Pressure according to the Work Postures on Fire Fighters (소방대원들의 작업자세에 따른 족저압력 분석)

  • Son, Sung Min;Roh, Hyo Lyun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.88-94
    • /
    • 2013
  • The purpose of this study is to find out the difference of foot pressure according to the firefighter's work postures for providing the basic information to prevent Musculoskeletal disorders. This study was conducted by 9 male firefighters. Work postures were selected for rescuee handling, fire hose and hydraulic rescue equipment work postures. These were divided into 3 position, "High", "Middle" and the postures of taking out and letting down hydraulic rescue equipment were analyzed as starting point and end point respectively. Foot Pressure was used to analyze contact area, peak pressure, and maximum force in terms of work postures, and compared between fire hose and hydraulic rescue equipment work postures. The results of foot pressure are as follows. According to the results of rescuee handling work postures, one person handling posture showed wide contact area and foot pressure showed the highest at right foot. Accoridng to the (High), (Middle), (Low) postures of fire hose, the results didn't show the difference among the contact area, peak pressure and maximum force. As the results of hydraulic rescue equipment work postures, (Low) postures showed the highest in terms of the right foot of contact area, peak pressure and maximum force and (High) postures showed the highest in left foot. The increase of foot pressure lead to be inconvenience of low extremity and muscle fatigue for maintaining postural control cause pain. Thus, it is necessary to design insole-equipped working shoe for reduce the impulse and effect of foot during the rescuee handling work which standing out as foot pressure.

A Study on the Development of Low Power Automatic ON/OFF Valve System for Gas Leak Detection (가스 누출 감지를 위한 저전력 자동 ON/OFF 밸브 시스템 개발에 관한 연구)

  • Choi, Young Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.369-374
    • /
    • 2021
  • Apartment recently built in kitchen is made is made because the gas hose with built-in ways invisible inside the sink. In this case, if the gas leaks, it is a dangerous method that can accumulate inside the sink and lead to an explosion. In this study, since the hose connected between the gas range and the intermediate valve is inside the sink, it is not possible to test for gas leaks, so a valve system that can easily check for gas leaks using a pressure sensor was studied. As for the pressure measurement method, the pressure of the hose connecting the intermediate valve and the gas range was measured so that data could be collected and analyzed using the I2C communication method. In addition, the calculation of the gas pressure supplied to the home was investigated for the atmospheric pressure error for the value calculated by adding the average value of the gas gauge pressure of 22.46 mbar at the inlet of the gas meter to the atmospheric pressure. A valve system was developed to detect minute gas leaks.

Measurement of acoustic impedance of porous woven hoses in engine intake systems in the presence of mean flow (유체의 흐름이 있는 엔진 흡기계용 직조관의 음향 임피던스 측정 및 전달손실 예측)

  • 이정권;박철민
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.996-1000
    • /
    • 2002
  • A porous tube, comprised of a resin-coated woven fabric has recently been used as an effective component for use in intake systems of internal combustion engines to reduce the intake roaring. For the prediction of the acoustic performance of an engine intake system with a porous woven hose, the acoustic wall impedance of the hose must be known. Because of its peculiar acoustical and structural characteristics, the accurate measurement of the wall impedance ofa porous woven hose is not easy. A new measurement technique is proposed herein, that is valid over the low to mid frequency ranges. The acoustics impedance is inversely estimated from an overdetermined set of measured pressure transmission coefficients for specimens of different lengths and the reflection coefficient of end termination. The method involves only one measurement, and, as a result, it is very simple. The measured TL for samples with arbitrary conditions, arbitrary porous frequency, arbitrary length, and arbitrary mean flow condition, are in reasonably good agreement with values predicted from curve-fitted impedance data.

  • PDF

A Study on the Mathematical Interpretation o Hydraulic Behaviour in Packing Tower (충전탑에서 수력학적 거동의 수학적 해석 연구)

  • 김석택
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.51-56
    • /
    • 2001
  • This study was carried out to interpret mathematically hydraulic behaviour in packing tower which packed 50 mm plastic Hiflow-ring with a dimension of 300 mm wide and 1,400 mm high. In view of energy saving, the recent packing. 50 mm plastic Higlow-ring was superior to conventional packings because of low pressure drop in high loads. As relative error between numerically predicted and experimentally obtained values was less then 6% in the loading and flooding point, it found that therir results appeared to be adequate. Comparison of hose two values in both dry and wet packing conditions. relative errors amount to 3.96 and 5.6%, respectively. In order to evaluate the operating characteristics of packing, the type, size, and material for packings must be estimated in various system and loads. This study is able to calculated pressure drop, hold-up, gas and liquid loads using mathematical interpretation. For these calculation, the specific constants of each packings must be calculated first all. The method of mathematical interpretation in this study turned out to be superior to the existing methods because of reduced errors at loading and flooding point.

  • PDF

Discharge Variation of Perforated Hoses and Drip Irrigation Systems for Protected Cultivation (시설재배용 분수호스 및 점적관수 시스템의 관수균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.297-302
    • /
    • 2007
  • Discharge variations of perforated hose and drip irrigation systems were examined to evaluate irrigation uniformity at different pressures and length of branch line. Evaluation using statistical uniformity indicated that button drippers performed at excellent level but drip tapes and drip hoses were a little lower level. Nominal discharge of drip irrigation systems showed at the high side within the range of regulating pressure provided by the manufacturer. It is desirable that the length of branch line for drip hose, drip tape, and button dripper should be limited to 50 m, 70 m, and 100 m, respectively. Irrigation uniformity of perforated hoses showed very low level. So it is recommended that the length of branch line for perforated hoses should be limited to $30{\sim}35m$.

Experimental Study on the Calibration of Bi-directional High Pressure Pile Load Test (양방향 고유압 말뚝재하시험장치의 보정에 관한 실험적 연구)

  • Choi, Yongkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.303-311
    • /
    • 2008
  • In the case of bi-directional high pressure pile load test with double-acting jack, the shortcomings of bi-directional pile load test with single-acting jack could be solved, low-cost of test could be sure, the limits of loading capacity could be overcome and quality assurance of service plie could be confirmed. In this study, to confirm the stability, the reliability and the application of bi-directional high pressure pile load test with double-acting jack, the calibration test for high pressure oil jacks, the length of high pressure hose and tunable high pressure pipe system were performed. As a result, credibility was very high because the reliability of test results was approached at about 1.0.

An Experimental Study on the Estimation Flow-rate of Venturi Pump Using LightGBM (LightGBM을 이용한 수력 펌프 유량 추정의 실험적 연구)

  • Jin Beom Jeong;Jihwan Lee;Myeongcheol Kang
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.123-132
    • /
    • 2023
  • In disaster situations, to facilitate rapid drainage, electric underwater pumps are installed manually. This poses a high risk of electric shock accidents due to a short circuit, and a lot of time is required for hose connection and installation of electrical devices. To solve these problems, a Venturi pump using the venturi effect without external power is used. However, Venturi pumps that operate without external power make it difficult to install flow sensors such as electric devices; consequently, it is difficult to check the real-time flow rate. This paper proposes a flow estimation logic to replace the function of the flow sensor for the venturi pump . To develop the flow estimation logic, the flow characteristics of the venturi pump, according to the operating conditions, were checked. After that, the relationship with the flow rate of the venturi pump was defined using a pressure sensor corresponding to a low-cost sensor. Finally, an analysis of the estimation error was performed using the developed flow estimation logic.