• Title/Summary/Keyword: Low insertion

Search Result 627, Processing Time 0.023 seconds

LTCC Technology for 60 GHz Applications

  • Kim, Hae-Cheon;Kim, Dong-Young;Mun, Jae-Kyoung;Jun, Dong-Suk;Yu, Hyun-Kyu
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2006.10a
    • /
    • pp.255-267
    • /
    • 2006
  • LTCC Technology is very suitable for 60 GHz application $\blacksquare$ LTCC substrate shows low loss at 60 GHz. - low insertion and return losses $\blacksquare$ Microstrip or CBCPW line is sultable for transmission lines at 60 GHz. - low loss (0.1dB/mm) $\blacksquare$ Single ribbbon bonding is adequate for interconnection - simple - low loss (0.1dB/bonding) $\blacksquare$ Characteristics of MMIC module - Gain difference (${\Delta}S21$) : 0.4 dB

  • PDF

Broadband Microwave SPDT Switch Using CPW Impedance Transform Network (CPW 임피던스 변환회로를 이용한 광대역 마이크로파 SPDT 스위치)

  • Lee Kang Ho;Park Hyung Moo;Rhee Jin Koo;Koo Kyung Heon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.7 s.337
    • /
    • pp.57-62
    • /
    • 2005
  • This paper describes the design of a high performance microwave single pole double throw (SPDT) monolithic microwave integrated circuit switch using GaAs pHEMT process. The switch design proposes a novel coplanar waveguide (CPW) impedance transform network which results in the low insertion loss and high isolation by compensating for the FET parasitics to get the low on-resistance and low off-capacitance. The proposed switch has the measured isolation of better than 24 dB and insertion loss of less than 2.6 dB from 53 to 61 GHz. The chip is fabricated with the size of 2.2mm $\times$ 1.6 mm.

Grain properties of low amylose endosperm induced by T-DNA insertion in Rice(Oryza sativa L.) (벼에서 T-DNA가 삽입된 저아밀로스 배유의 미립특성)

  • Park, Se-Ug;Lee, Hyun-Suk;Sohn, Jae-Keun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.29
    • /
    • pp.1-10
    • /
    • 2011
  • This study was conducted to determine the agronomic characteristics of low amylose lines which were derived from induced mutants by T-DNA insertion. The agronomic and physicochemical properties of the low amylose mutants were analyzed and compared with a donor cultivar 'Dongjin' and a low amylose cultivar 'Baekjinju'. The heading date of the low amylose mutants was similar to the donor cultivar 'Dongjin' and yield index of the mutants was 78~92% compared with 'Dongjin'. The amylose content of four mutants in brown rice was ranged from 16.1 to 16.7%. Among low amylose mutants, 'P50-4-4-5' was lower 3.6%(13.3%) than those of 'Dongjin'(16.9%) in amylose content of milled rice. The grain length of 'P50-4-4-5' was similar to the donor cultivar, however, thousand grain weight(18.9g) was lighter than those of 'Dongjin'. The score of alkali digestion in brown rice of 'P50-4-4-5'(5.5) was lower than that of 'Dongjin'(6.8) and similar to 'Baekjinju'(5.8). The gel consistency of 'P50-4-4-5'(84mm) in milled rice exhibited that was longer than 'Dongjin'(76mm) and 'Baekjinju'(81mm). The result of eating quality showed that 'P50-4-4-5'(78.8) was higher than those of 'Dongjin'(60.3) and 'Baekjinju'(67.2). Thus our data suggest that 'P50-4-4-5' will facilitate the development of a new cultivar with low amylose rice.

  • PDF

Qualitative and quantitative evaluation of root injury risk potentially burdening insertion of miniscrew implants

  • Antoszewska, Joanna;Trzesniewska, Paulina;Kawala, Beata;Ludwig, Bjorn;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.112-120
    • /
    • 2011
  • Objective: Microscrew implants (MSls) offer many advantages, but some complications are known to occur during their insertion. One of the most commonly reported complications is root injury. Our aim was to identify factors associated with root injury and to evaluate their qualitative and quantitative values. Methods: Thirty-five orthodontists placed MSls (AbsoAnchor$AbsoAnchor^{(R)}$, Dentos Co. Ltd, Daegu, Korea) in the upper jaw of typodonts, labially between the second premolar and the first molar, in low and high vertical positions. Root contacts were counted, and distances between MSI apices and roots were measured. Fear level of the orthodontists was surveyed before and after the experiment. Wilcoxon's test, chi-square test, and Mann-Whitney test were used for statistical analysis. Results: Overall root contact rate of MSI insertion was 23.57%. The root contact rate was significantly higher in MSls inserted at $90^{\circ}$ (45.71%) than at $30^{\circ}$ (1.43%). The distance between the dental root and MSI also increased significantly in MSls inserted at $30^{\circ}$. Mean fear level before MSI insertion (4.6) significantly decreased after insertion (3.2); the causative factors were risk of injury to dental root and maxillary sinus or mandibular canal. Conclusions: Root injury is relatively rare, and oblique angulation reduces the risk of root and MSI contact.

The Development of a Flexible and Sensible Robot Wrist for Aseembly Process (유연하고 감지성있는 조립전용 로봇 손목 의 개발 에 대한 연구)

  • 조형석;고경철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.5
    • /
    • pp.488-497
    • /
    • 1984
  • In the assembling process by industrial robots, many difficulties stem from the fact that the assembly operation is impossible or the parts to be assembled can be damaged by reaction forces due to even little misalignment in part mating. In this paper a flexible and sensible robot wrist is developed to make possible the precision insertion operation. The flexibility of the developed wrist were evaluated both analytically and experimentally in actual insertion process. The results show that without the use of feedback control the wrist is capable of doing insertion operations with a small clearance at a low inserting force. For smaller clearance the assembly process was devised involving insertion force feedback and a control algorithm for this active accommodation was developed. The simulation results show that if the active feedback control is used the insertion action can be performed with much less force, as compared with a passive accommodation method.

TMPRSS2:ETS Fusions and Clinicopathologic Characteristics of Prostate Cancer Patients from Eastern China

  • Dong, Jun;Xiao, Li;Sheng, Lu;Xu, Jun;Sun, Zhong-Quan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3099-3103
    • /
    • 2014
  • TMPRSS2:ERG gene fusions in prostate cancer have a dominant prevalence of approximately 50.0%, but infomration is limited on differences among ethnic and geographical groups. Some studies focusing on Japanese and Korean patients reported a lower incidence. Investigations concerning Chinese revealed controversial results. We evaluated TMPRSS2:ERG, TMPRSS2:ETV1 and TMPRSS2:ETV4 fusions in more than 100 Eastern Chinese prostate cancer patients. Paraffin blocks of needle biopsy and radical prostatectomy were collected from 91 and 18 patients respectively. All patients' clinicopathologic factors were gathered. TMPRSS2:ERG, TMPRSS2:ETV1 and TMPRSS2:ETV4 fusions were tested by multi-probe fluorescence in situ hybridization (FISH) assay. TMPRSS2:ERG fusions was present in 14.3% biopsy specimens and 11.1% radical prostatectomy patients. Neither TMPRSS2:ETV1 nor TMPRSS2:ETV4 fusion was found in any case. Altogether, 13 (86.7%) TMPRSS2:ERG fusion positive cases possessed deletion pattern and 7 (46.6%) and insertion pattern. Some 5 cases had both deletion and insertion patterns. While 38.5% (5/13) patients with deletion pattern had distant metastasis, except for one metastatic case harboring both deletion and insertion, there were no patients with insertion pattern accompanied with metastasis. There were no differences between fusion positive and negative cases in the distribution of age, PSA, Gleason score and TNM stage. Eastern Chinese prostate cancer patients have a significantly low incidence of TMPRSS2:ERG fusion. They also lack TMPRSS2:ETV1 and TMPRSS2:ETV4 fusion. There are more deletion pattern than insertion pattern in TMPRSS2:ERG positive cases. Fusion positive and negative patients have no clinicopathologic factor differences.

The effect of the thread depth on the mechanical properties of the dental implant

  • Lee, Sun-Young;Kim, Sung-Jun;An, Hyun-Wook;Kim, Hyun-Seung;Ha, Dong-Guk;Ryo, Kyung-Ho;Park, Kwang-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.115-121
    • /
    • 2015
  • PURPOSE. This study aimed to evaluate the effect of implant thread depth on primary stability in low density bone. MATERIALS AND METHODS. The insertion torque was measured by inserting Ti implants with different thread depths into solid rigid polyurethane blocks (Sawbones) with three different bone densities ($0.16g/cm^3$, $0.24g/cm^3$, and $0.32g/cm^3$). The insertion torque value was evaluated with a surgical engine. The static compressive strength was measured with a universal testing machine (UTM) and the Ti implants were aligned at $30^{\circ}$ against the loading direction of the UTM. After the static compressive strength test, the Ti implants were analyzed with a Measurescope. RESULTS. The Ti implants with deeper thread depth showed statistically higher mean insertion torque values (P<.001). Groups A and group B had similar maximum static compressive strengths, as did groups C and D (P>.05). After the static compressive strength, the thread shape of the Ti implants with deeper thread depth did not show any breakage but did show deformation of the implant body and abutment. CONCLUSION. The implants with deeper thread depth had higher mean insertion torque values but not lower compressive strength. The deep threads had a mechanical stability. Implants with deeper thread depth may increase the primary stability in areas of poor quality bone without decreasing mechanical strength.

Acoustic Performance Evaluation of Noise Barriers Installed Adjacent to Rails and Suggestion of Approximation Formula for the Prediction of Insertion Loss (근접 방음벽의 음향성능평가 및 삽입손실 예측을 위한 근사식의 제안)

  • Yoon, Je Won;Jang, Kang Seok;Cho, Yong Thung
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.5
    • /
    • pp.629-637
    • /
    • 2016
  • In this paper, an investigation was conducted to evaluate the acoustic performance of low height noise barriers installed adjacent to rails; an easy-to-use approximation formula was suggested for the evaluation of insertion loss (IL), instead of using the boundary element method. At first, the acoustic performance of the low height noise barriers was measured in an anechoic chamber using a scaled down model; the overall IL according to the source location was analyzed with the equivalent IL contour line. Using the measurement results obtained from the scaled down model, an approximation formula was suggested for the IL of low height noise barriers having various shapes. Also, the prediction program was validated through a comparison between the actual measurement results in the anechoic chamber and the prediction results. Finally, using the prediction program, an approximation formula for IL was suggested for the low height noise absorption barriers. Considering the frequency characteristics of the noise sources of the train, the absorptive low height noise barriers have a 'ㄱ' type shape, a height of 1.0m, and a length of 0.5m when they are installed on the structure gauge for the train.

The Evaluations of Fish Survival Rate and Fish Movements using the Tagging Monitoring Approach of Passive Integrated Transponders (PIT) (수동형 전자발신장치(Passive Integrated Transponder, PIT) 모니터링 기법 적용에 따른 어종별 생존율 평가 및 어도에서 어류이동성 평가)

  • Choi, Ji-Woong;An, Kwang-Guk
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1495-1505
    • /
    • 2014
  • The objective of this study was to evaluate survival rate and fish movement (migration) using a tagging approach of passive integrated transponder (PIT) in Juksan Weir, which was constructed as a four major river restoration projects. For this study, survival rates of each fish species and the mobility of fish individuals were analyzed during 2 weeks by the insertion of PIT tags to various fish species in the laboratory. According to tagging tests in the laboratory, the survival rate 37.5% (30 survivals of 80 individuals) after the insertion of PIT tags. The survival rate of Carassius auratus and Hemibarbus labeo was 100% and 80% after the insertion of the tags, respectively, whereas it was only 13.3% for Zacco platypus. In the field experiments of Juksan Weir, 6 species and 157 individuals from 8 species (563 individuals) were detected in the fixed automatic data-logging system, indicating a detection rate of 27.9% in the fishway of Juksan Weir. In the meantime, some species with no or low detection rates in the fixed automatic data-logging system were turn out to be stagnant-type species, which prefer stagnant or standing water to live.

Design and Performance Test of Silencers with Ring-shaped Resonators (환형 공명기가 설치된 소음기 설계 및 성능 시험)

  • Kim, Bong-Ki;Kim, Sang-Ryul;Lee, Seong-Hyun;Lee, Jong-Hwa;Lee, Hae-Seong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.357-364
    • /
    • 2011
  • In this study, ring-shaped acoustic resonators were proposed to be installed in a silencer to increase the acoustic performance of silencer in the low-frequency range. Evaluation of noise reduction performance of acoustic resonator arrays was carried out by measuring the random-incidence absorption coefficient. It was found that the absorption coefficient of resonator array was measured up to 1 at 125 Hz of 1/3-octave band center frequency. Insertion losses of silencers with ring-shaped acoustic resonator arrays were measured based on ISO 7235. The results were shown that the ring-shaped resonator could increase the insertion loss up to 13 dB without flow, whereas 7 dB when flow speed reached 15 m/s. As increasing the flow speed above 15 m/s, the effect of acoustic resonator decreased due to the effect of nonlinear air damping of the resonator. It was also found that the increment of pressure drop by the presence of resonator arrays was about 9 % at flow speed of 25 m/s.