• 제목/요약/키워드: Low humidity

검색결과 1,034건 처리시간 0.027초

Effects of Long-term Exposure of High and Low Humidity on Thin-film Humidity Sensors

  • Lee, Sang-Wook;Choi, Byung Il;Kim, Jong Chul;Woo, Sang-Bong
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.368-373
    • /
    • 2018
  • The effects of long-term exposure of high and low humidity on thin-film humidity sensors are investigated. Five commercially available thin-film humidity sensors are initially calibrated in a humidity chamber as a reference before longterm exposure to high and low humidity. Then, the sensors are kept in a high-humidity environment (~95 %rh) for four months. After the exposure, the sensors are calibrated in the same manner as the initial calibration. Consequently, the device reading values from the humidity sensors are elevated up to about 5 %rh. Interestingly, the degree of elevation by the high-humidity exposure shows a negative correlation with the price of the humidity sensors. Humidity sensors are then kept in a low-humidity environment (~10 %rh) for another four months. After the exposure, a calibration similar to the initial calibration is performed. As a result, the device reading from humidity sensors is decreased, indicating a recovery from the effect of high-humidity exposure. The durability test conducted in this study provides experimental evidence for the use of thin-film humidity sensors in high-humidity environments such as greenhouses and food factories for a long period of time.

저가보급형 습도조절용 세라믹패널의 조습성능 평가 - 리빙랩 온·습도 모니터링 분석을 통한 실측결과를 중심으로 - (Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Low-Priced Generic Ceramic Panel Materials for Humidity Control - Focuses on analyzed measurements of temperature and humidity obtained from the housing units -)

  • 장건영;류동우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.39-40
    • /
    • 2017
  • This study aims to evaluate the humidity control performance of low-priced generic ceramic panels that are used to control humidity. Temperature and humidity are monitored by using 'Living Lab' and the change of indoor relative humidity is measured and analyzed. According to the results of the study, the indoor relative humidity of rooms installed with ceramic panels was found to be low compared to that of living rooms by 2.2%RH (test period) and 3.2%RH (daily). In the case of maximum relative humidity, rooms installed with ceramic panels were found to be low by 6.9%RH. The results are attributable to the humidity absorption of ceramic panels. Accordingly, future ceramic panels need the improvement of performance and an appropriate construction area should be derived depending on indoor space.

  • PDF

분류식 습도 발생 장치 개발 및 라디오존데 습도센서 저온 효과 보정에 활용 연구 (Development of a divided-flow humidity generator and its use for studying low-temperature effects on radiosonde humidity sensors)

  • 장은정;이영석;최병일;최윤석;이상욱
    • 센서학회지
    • /
    • 제30권4호
    • /
    • pp.243-249
    • /
    • 2021
  • Humidity is an important physical quantity that is closely related with the quality of everyday life as well as the quality control of products in various industries. Here, we have developed a divided-flow type humidity generator of which humidity generation is faster than the saturator-based humidity generator in ppm level. The operation principle of the divided-flow humidity generator is first introduced. Then, the performance of the divided-flow humidity generator is verified by testing the radiosonde humidity sensor at low temperature. As a result, the humidity generated from the divided-flow humidity generator is consistent with the saturator-based precision humidity generator within 1.6% relative humidity in the range from 10% to 40% at -45 ℃. It is also found that the radiosonde humidity sensor shows measurement errors by 3% - 5% at -45 ℃ when it is only calibrated at room temperature. The response times of radiosonde humidity sensor using the divided-flow humidity generator are between about 2 and 9 minutes, whereas those by the saturator-based humidity generator are about 20 minutes. In this regard, the divided-flow humidity generator has a merit in terms of fast humidity changes for the calibration of radiosonde humidity sensors at low-temperatures.

극건조 환경에서 염화티오닐 동시 노출자의 자각증상 경험률 (Self-reported Irritation Symptoms among Workers Exposed to Ultra-low Relative Humidity and Thionyl Chloride)

  • 채유미
    • 한국환경보건학회지
    • /
    • 제41권6호
    • /
    • pp.412-424
    • /
    • 2015
  • Objectives: An ultra dry air environment of nearly ${\leq}2%$ RH is often required in lithium battery factories. The objective of this study is to evaluate the subjective eye, pulmonary, nose, and skin symptoms of workers exposed to ultra-low relative humidity and thionyl chloride. Methods: We recruited 274 workers using a self-reported questionnaire in March 2014. Those who worked in ultra-low relative humidity and with thionyl chloride were identified and their prevalence of symptoms was compared with that of other workers. We excluded white collar workers, researchers and other workers who were exposed to various hazard factors, and finally included 164 workers. Results: There were significant differences in the rate of self-reported eye and skin symptoms between exposure group_1 and exposure group_2. Exposure group_2 experienced more frequent eye, and skin symptoms. Multinomial logistic regression analysis for experience of dry eye symptoms and skin symptoms in exposure group_2 showed that dry eye symptoms (odds ratio [OR], 6.33, 95% confidence interval [CI], 2.19-18.24, p<0.001), and itchiness (OR, 6.45, 95% CI, 1.94-21.43, p<0.01) were the significant variables. The complaints of workers experiencing ultra-low relative humidity and thionyl chloride were high compared with other workers. Conclusion: These findings suggest that exposure to ultra-low relative humidity and thionyl chloride may be associated with more frequent eye and skin symptoms than exposure to ultra-low relative humidity alone. The current precautions to protect workers from the adverse effects of ultra-low relative humidity and thionyl chloride appear to be insufficient, indicating that additional management plans to reduce symptoms should be considered.

식물생장용 저압챔버 내의 기온, 상대습도 및 압력의 변화 (Variations of Air Temperature, Relative Humidity and Pressure in a Low Pressure Chamber for Plant Growth)

  • 박종현;김용현
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.200-207
    • /
    • 2009
  • This study was conducted to analyze the variations of air temperature, relative humidity and pressure in a low pressure chamber for plant growth. The low pressure chamber was composed of an acrylic cylinder, a stainless plate, a mass flow controller, an elastomer pressure controller, a read-out-box, a vacuum pump, and sensors of air temperature, relative humidity, and pressure. The pressure leakage in the low pressure chamber was greatly affected by the material and connection method of tubes. The leakage rate in the low pressure chamber with the welding of the stainless tubes and a plate decreased by $0.21kPa{\cdot}h^{-1}$, whereas the leakage in the low pressure chamber with teflon tube and rubber O-ring was given by $1.03kPa{\cdot}h^{-1}$. Pressure in the low pressure chamber was sensitively fluctuated by the air temperature inside the chamber. An elastomer pressure controller was installed to keep the pressure in the low pressure chamber at a setting value. However, inside relative humidity at dark period increased to saturation level.. Two levels (25 and 50kPa) of pressure and two levels (500 and 1,000sccm) of mass flow rate were provided to investigate the effect of low pressure and mass flow rate on relative humidity inside the chamber. It was concluded that low setting value of pressure and high mass flow rate of mixed gas were the effective methods to control the pressure and to suppress the excessive rise of relative humidity inside the chamber.

저습도 사이클 조건에서의 라이너지와 골판지의 물성 (Physical Properties of Linerboard and Corrugated Fiberboard at the Cyclic Condition of Low Humidity)

  • 윤혜정;이학래;진성민;최익선
    • 펄프종이기술
    • /
    • 제39권2호
    • /
    • pp.38-44
    • /
    • 2007
  • The hygroscopic property of paper is important for convertability and end use performance. When the board and corrugated fiberboard are exposed to low relative humidity, a trouble of score (or crease) cracking could occur. In this study, we evaluated the moisture content and mechanical properties of linerboard and corrugated board at the cyclic condition of low humidity to prevent a score crack trouble. As the relative humidity decreased from 50% to 38% and 25%, the moisture content of linerboard decreased about 7% to 6% and 4%. At low humidity, most of mechanical properties were improved except for strain. The linerboard exposed at 25% RH showed a remarkable reduction of strain by 11%. At the same relative humidity, linerboard and corrugated fiberboard showed the different property values depending on moisture hysteresis.

질화탄소막의 물리적 특성과 센서재료 응용에 관한 연구 (A Study on Physical Properties of Carbon Nitride Films and Application for Sensor Materials)

  • 김성엽;이지공;장중원;이성필
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.436-442
    • /
    • 2007
  • Physical properties and impedance-humidity characteristics of carbon nitride films were investigated for micro-humidity-sensors. Carbon nitride films were deposited in low temperature and low power for application of semiconductor fabrication process, and empirical equation was proposed for thickness evaluation. Deposited films had an uniform and compact surface comparing with previously reported results, which was expected a good candidate for humidity sensing materials. Carbon nitride humidity sensors based on Si substrate revealed good humidity-impedance characteristics with a wide range of relative humidity and showed low hysteresis.

실내조경에 있어서 양치식물의 수분환경 관리방안에 관한 연구 (A Study on the Management Plan of Water Environment of Ferns in the Interior Landscape)

  • 주진희;방광자;설종호
    • 한국조경학회지
    • /
    • 제27권1호
    • /
    • pp.122-131
    • /
    • 1999
  • Indoor environments are usually less than optimal for the growth of ferns, especially in regards to the water condition. These studies were performed to investigate responses involved in causing growth of ferns and presume management plan against the water deficit under indoor conditions. The effect of air humidity and soil moisture on the ferns was examined in Adiantume raddianum and Selaginella kraussiana. Results of experiments are as follows; 1. Under a low humidity condition, having a 25-50% RH. ornamental value of ferns decreased much more than under a 90% RH. Under a low soil moisture, such as sand treatment, ornamental value of ferns also decreased. 2. Leaf chlorophyll content, water content and stomata situations increased as air humidity and soil moisture went up. 3. Even if air humidity and soil water were not enough for ferns growth, the extending of irrigation cycle was helpful. 4. Under extremely low air humidity conditions, some water management, namely, using water holding soil or extending of irrigation cycle was desirable. Other methods of increasing air humidity, including water instruments such as ornamental pools, waterfalls, or fountains, grouping plants together were also helpful. But spraying water on leaves increased injury to ferns growth because of excess evaporation from the leaves. Though these studies, we learn that ferns are susceptible to water condition such as air humidity, soil water and water management. If other environmental factos are maintained with optimal conditions, water condition plays an important role in ferns growth in indoor environments.

  • PDF

폴리이미드 박막을 이용한 집적화 습도센서 (An Integrated Humidity Sensor Based on Thin Polyimide Films)

  • 안광호;민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1388-1390
    • /
    • 1994
  • A polyimide-based capacitive humidity sensor has been designed and fabricated using silicon integrated-circuit technology, and its performance measured. The sensor showed excellent linearity, low temperature coefficient, and low hysteresis over a wide range of relative humidity and temperature. The signal conditioning circuits for detecting relative humidity and converting it to voltage have been developed based on a charge redistribution between capacitors using switched -capacitors.

  • PDF

저전류/저가습 조건에서 고분자전해질 막 열화 (Degradation of Polymer Electrolyte Membrane under Low Current/Low Humidity Conditions)

  • 김태희;이정훈;이호;임태원;박권필
    • 한국수소및신에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.157-163
    • /
    • 2007
  • During PEMFC operation, low current and low humidity conditions accelerate the degradation of perfluorosulfonic acid membrane. But, there have been no studies that clearly explain why these conditions accelerate the membrane degradation. In this study, the hydrogen permeability through the membrane, I-V polarization of MEA, fluoride emission rate(FER) in effluent water were measured during cell operation under low current densities and low relative humidity(RH). The experimental results were evaluated with oxygen radical mechanism the most commonly known for membrane degradation. It seems that low RH of anode is a good condition for $H{\cdot}$ radical formation on the Pt catalyst and the low current condition accelerates the $H{\cdot}$ to form $HO_2{\cdot}$ radical attacking the polymer membrane.