시멘트특성에 따른 콘크리트의 물리적 성질에 관한 실험적 연구 (An Experimental Study on the Physical Properties of Concrete Using all kinds of Cements)

  • 김상철;노재호;강승희;최수홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.36-41
    • /
    • 1996
  • The selection of Cement types is greatly dependent on the structural requirement and consturction location associated with control of hydration heat, acquisition of early strength, existence of sulfate attacks and so on. Based on this, this study adresses the comparison of physical properties of concrete according to the use of different cement types. As a result of testing with OPC, blast furnace slag and low heat cement, it is found that concrete made with low heat cement is much better in term of hydration heat and permeability. It is also recommended to select a preper cement type depending on structural characteristics.

  • PDF

저발열형 시멘트 콘크리트의 염소이온 침투$\cdot$확산에 대한 저항성 (The Resistance of Penetrability and Diffusion of Chloride Ion in Blended Low Heat Type Cement Concrete)

  • 문한영;신화철
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.31-41
    • /
    • 1999
  • Blended Low Heat type cement is ground granulated blast furnace slag and fly ash mixed ternary with ordinary portland cement. From the viewpoint of X-ray patterns of domestic LHC, the main components of cement such as $C_2$S, $C_3$A, $C_3$S are considerably reduced. Therefore the heat evolution of LHC paste is 42cal/g lower than of OPC paste. At early age, the compressive strength development of LHC concrete is delayed, but the slump loss ratio of fresh concrete is reduced more than 20% with elapsed time. The penetrability of LHC is lower than that of OPC by 1/7.8 with the penetrability of chloride ion into the concrete until the age of 120 days. And the PD Index value of LHC is 0.44$\times$10-6 $\textrm{cm}^2$/s, which indicates only 39.3% of OPC. From the Mercury Intrusion Porosimetry test of cement past, we know that the pore size of LHC is more dense than that of OPC by production of C-S-H.

저 분말도 슬래그를 사용한 슬래그 시멘트의 특성 (The Characteristics of Blastfurnace Slag Blended Cement with Low Blaine Slag Powder)

  • 변승호;최현국;김재영;송종택
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표회 논문집(I)
    • /
    • pp.19-24
    • /
    • 1998
  • In this study, blended cement with low blaine(2000, 3000$\textrm{cm}^2$/g) blast-furnace slag power by 10-70wt.% was investigated through the measurement hydration heat, physical properties. The experiment results indicated compressive strength was decreased as low blaine slag blended, but hydration heat was reduced significantly and flow of the cement paste was increased.

  • PDF

저열 포틀랜드(벨라이트)시멘트 콘크리트의 특성 (Properties of Low Heat Portland(Belite Rich) Cement Concrete)

  • 하재담;김기수;김동석;구본창;조계홍;이동윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표회 논문집(I)
    • /
    • pp.66-71
    • /
    • 1998
  • Recently, it has been increased to construct massive concrete structures, like under-ground structure, offshore structure etc., ie. concrete construction have become larger and higher and are demanding lower heat concrete to prevent thermal cracking. It has been progressed to replace cements with fly-ash and slag to lower heat of hydration, but it is hard to control quality of the mineral admixtures in stage of adjusting of real construction. Application of low heat portland(Belite Rich) cement for the mass concrete is the best solution to satisfied those requirements. Here are explained the basic properties of fresh concrete as well as hardened concrete of using low heat portland cement(LHPC). Also, we compare the results of adiabatic temperature rise test using LHPC and OPC.

  • PDF

시멘트 종류에 따른 저발열 콘크리트의 품질특성에 관한 연구 (A Study on the Quality Properties of Low Heat Concrete according to Kinds of Cement)

  • 김성;최성우;조현태;전준영;류득현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.777-780
    • /
    • 2006
  • Recently, owing to the development of industry and the improvement of building techniques, the concrete structure is becoming larger and higher. In hardening these large concrete, the heat of hydration gives rise to considerable thermal stress depending on the size and environmental condition of concrete, which might cause thermal cracking. Especially, the crack may cause severe damage to the safety and the durability of concrete structure. This study is investigated the thermal properties of concrete according to several binder conditions, such as OPC, Belite Rich Cement(BRC), Low-Heat-Mixed Cement(LHC), Fly ash added cement. As a result of this study, the Flowability of concrete was beetter with BRC and LHC than FA(25) and OPC. On the other hand, LHC gets superior effect in the control of heat hydration, it's caused by the volume of OPC.

  • PDF

저열 포틀랜드 시멘트를 사용한 고유동콘크리트의 사용재료 및 배합 변동에 따른 특성 평가 (The Effect on the Properties of High Flowing Concrete Using Low Heat Portland Cement by Material and Mixing Variations)

  • 하재담;김태홍;유재상;이종열;권영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.303-308
    • /
    • 2001
  • Recently, concrete structures have become larger and higher and are demanding high performance concrete with lower heat to prevent thermal cracking, far greater workability, high strength and durability, Application of low heat portland(Type IV) cement for the high performance concrete is the best solution to satisfied those requirements. Here are explained the effect on the properties of high flowing concrete using low heat portland cement by material and mixing variations. Variables for sensitivity test were selected items like finess modulus of aggregates, particle size of limestone powder, unit water, superplasticizer, viscosity agent and concrete temperature. The results of this study were be applied to slurry wall of #215 and #216 of underground LNG tank in Inchon.

  • PDF

포틀랜드시멘트계 경화체의 황산염저항성 (Sulfate Resistance of Portland CementMatrices)

  • 문한영;이승태;김홍삼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.714-717
    • /
    • 2000
  • To consider sulfate resistance of cement pastes and motars for 3 types of portland cements which have different $C_3A$ contents an silicate ratio($C_3S/C_2S$), they were immersed in 5% sodium sulfate solution for 400 days. SEM analysis and ($Ca(OH)_2$ contents of cement pastes, and compressive strength and length change of cement mortars, were performed to investigate the effects of ($C_3$ and ($Ca(OH)_2$ contents. According to the results of this study, low heat portland cement pastes, and compressive strength and length change of cement mortars, were performed to investigate the effects of C3A and ($Ca(OH)_2$ contents. According to the results of this study, low heat portland cement had a good sulfate resistances because of a small quantity of gypsum and ettringite due to less ($Ca(OH)_2$ contents. However, ordinary portland cement had an adverse result. This was also confirmed by SEM analysis.

  • PDF

시멘트 유동성과 물성에 미치는 영향인자에 관한 연구 (A Study of Effecting Factor in the Reology and Physical Properties of Cements)

  • 엄태선;최상흘
    • 한국세라믹학회지
    • /
    • 제34권10호
    • /
    • pp.1027-1036
    • /
    • 1997
  • The reology and several physical properties of cements are studied by varying the different mineral composition and particle size distribution(PSD) of cements with closed circuit ball mill for high workability, low heat of hydration, and high strength. In this study, we found that the workability of concretes is related to the viscosity of cement, and affects to strength. Here, this workability is affected by mineral composition (C3A) and the PSD. Especially, rosin-rammer index and 44${\mu}{\textrm}{m}$ residue in the PSD of cements are affected to water demand, casting property, slump loss, strength of cements. From the above results, the conditions of cement for high workability, low heat of hydration and high strength are to use low C3A clinker, 5-10% slag addition, and to grind cement below 0.7 rosin-rammer index, above 3.5-4.5% 44 ${\mu}{\textrm}{m}$ residue, 4000$\pm$100 $\textrm{cm}^2$/g blaine. Such cements are, therefore, supurior to super low heat cement and slag-blended cement in comparing the physical properties of strength, slump, slump-flow, adiabetic temperature, etc.

  • PDF

매스콘크리트 구조물에서의 시멘트 종류별 수화발열 특성 평가 (Evaluation of Thermal Characteristics in Association with Cement Types in Massive Concrete Structure)

  • 김상철;강석화;김진근
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.3-12
    • /
    • 1999
  • The larger, loftier and more highly strengthened the recent structures become, the greater attention is paid to the problem of thermal crack occurrence associate with hydration heat. As one of methods to solve the problem, a care has been taken to the improvement of construction such as the application of pre-cooling or pipe-cooling, adjustment of concrete block size, concrete placement timing, joint arrangement and so on. But it is expected that a proper selection of cement shall additionally contribute to the control of thermal cracks. In this study, thus, we selected 4 types of cements such as Type V for anti-sulphate, blast furnace cements (slag content of 45% and 65% respectively)and ternary blended low heat cement, and carried out mock-up tests. In every assigned time, temperatures and thermal stresses were measured and calculated from raw data. As a result of measurement, it was found that the magnitude of hydration heat is in order of blast furnace slag cement. Type V and ternary blended low heat cement. Results of thermal stresses were same as the order of temperature. In addition, thermal stresses calculated from the data of strain gauges showed almost similar to those measured from effective stress gauges only when strain values were adjusted properly in accordance with initial time of stress appearance. Theoretical results agreed well with the measured values comparatively, but showed slight differences. It is inferred that these differences shall be reduced if more tests capable of evaluating thermal characteristics of concrete are carried out.

산업부산물을 혼합하여 제작한 3성분계 시멘트 콘크리트의 성능 평가 (Evaluation on the Properties of Ternary blended Cement Concrete using Industrial Byproducts)

  • 김춘호;김남욱
    • 자원리싸이클링
    • /
    • 제23권3호
    • /
    • pp.13-20
    • /
    • 2014
  • 현재 산업 및 토목기술의 발전으로 인한 콘크리트 구조물의 대형화 및 다양화가 시도되고 있으나 대형 구조물의 시공 시 발생하는 수화열은 온도균열을 유발하여 콘크리트 구조물의 내구성능을 저하시키는 문제를 발생한다. 본 논문은 시멘트의 종류에 따른 콘크리트의 내구성능 및 수화열 저감 특성을 고찰하기 위하여 보통포틀랜드시멘트, 플라이애쉬를 혼합한 2성분계 시멘트, 플라이애쉬와 고로슬래그를 혼합한 3성분계 시멘트 및 저발열 시멘트를 각 각 사용하여 제작한 콘크리트의 물성, 내구성능 및 수화특성 등의 결과를 비교 분석한 결과, 3성분계 혼합 시멘트가 내구성능 및 수화열 저감 효과에 가장 우수한 것으로 나타나 매스 콘크리트 및 내구성능이 요구되는 구조물 축조에 적합하다고 판단되었다.