• Title/Summary/Keyword: Low cost

Search Result 9,528, Processing Time 0.039 seconds

Children's Prosocial Moral Reasoning and Prosocial Behavior (과제의 부담과 종류에 따른 아동의 친사회적 도덕추론과 친사회적 행동)

  • Lee, Ok Kyung;Yi, Soon Hyung
    • Korean Journal of Child Studies
    • /
    • v.17 no.1
    • /
    • pp.275-288
    • /
    • 1996
  • The purposes of this study were to investigate children's prosocial behavior by age and sex and to examine the relationship between children's prosocial moral reasoning and prosocial behavior by costs and types of tasks. The subjects were 300 3th-and 6th-graders enrolled in elementary schools in Seoul. The revised form of Prosocial Moral Dilemmas including costs and types of tasks was used. The tasks of prosocial behaviors included time-cost tasks, money-cost tasks and physical strength-cost tasks. For data analysis, the paired t-test, two-way ANOVA, and Pearson's Correlations were used. Major findings were as follows; (1)There was age difference in children's prosocial behavior. 6th-graders performed at a higher level than 3th-graders. Sex differences weren't significant. In low- and high-cost tasks and in time-, money-, and physical strength-cost tasks, there were (2) Scores on high-cost behavior tasks were higher than on low-cost tasks. (3) Children's prosocial moral reasoning was positively related to prosocial behavior; in low- and high-cost tasks, and in time-, money-, and physical strength-cost tasks.

  • PDF

Cost Effectiveness of Bse-Isolation for Bridges in Low and Moderate Seismic Region (중저진 지역에서의 지진격리교량의 경제적 효율성에 관한 연구)

  • 고현무
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.178-185
    • /
    • 1999
  • Minimum life-cycle cost helps to evaluate cost effectiveness of base-isolated bridges under specific condition. Life-cycle cost mainly consists of the initial construction cost and the expected damage cost. Damage cost estimation needs proper model of input ground motion failure probability evaluation method and limit states definition. We model the input ground motion as spectral density function compatible with the response spectra defined at each seismicity and site condition. Spectrum analysis and crossing theory is suitable for reseating calculation of failure probabilities in the process of cost minimization. Limit states of base-isolated bridges re defined for superstructure isolator and pier respectively The method is applied to both base-isolated bridges and conventional bridges under the same conditions to investigate cost effectiveness of base isolation in low and moderate seismic region. the results show that base-isolation of bridges are more effective in low and moderate seismic region and that the site effects on the economical efficiency may not be negligible in such a region.

  • PDF

An Analysis on the Efficiency of Low-Cost Air Lines in Korea (국내 저가항공사 노선 효율성 평가)

  • Choi, Ki-Seoun;Kim, Woo-Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.5
    • /
    • pp.436-444
    • /
    • 2018
  • The purpose of this research is to assess the efficiency of the airline's route. The revenue source of low cost airline carriers is not various unlike regular airline carriers, because they are operating only domestic and international flights for a country of close proximity. In particular, domestic low-cost airlines in Korea can't provide cargo transport services but rely on passengers and additional services to generate profits. Therefore, it is absolutely important to maintain a low cost and effective passenger transport line. This study will suggest the way to improve efficiency of route operated by low-cost airlines. Analysis method is DEA. The input parameters and output results were selected by existing research. Based on the results of this study, it will be able to assist establishing routes and selling strategies of the low-cost airlines.

Power Factor Correction of Single-phase Boost Converter for Low-cost Type UPS Configuration (저 가격형 UPS를 구성하기 위한 단상 부스트 컨버터의 고 역률 제어)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.145-150
    • /
    • 2013
  • A novel AC to DC PWM converters with unity input power factor are proposed to overcome the above shortcoming. The main function of these converters is to shape the input line current to force it exactly in phase with the input AC voltage. Therefore, the input power factor can be improved to near unity and the input current harmonics can be eliminated. In this paper, half-bridge converter with two active switches and two diodes are utilized for low-cost type UPS configuration. By having only two semiconductors in the current path at any time, losses can be reduced over the conventional boost topology. Also, this converter provides controllable dc-link voltage, high power factor, and low cost type converter by simple power circuits. Simulation results show that the proposed half-bridge converter/inverter control technique can be applied to single-phase low-cost type UPS systems successfully.

A low-cost compensated approximate multiplier for Bfloat16 data processing on convolutional neural network inference

  • Kim, HyunJin
    • ETRI Journal
    • /
    • v.43 no.4
    • /
    • pp.684-693
    • /
    • 2021
  • This paper presents a low-cost two-stage approximate multiplier for bfloat16 (brain floating-point) data processing. For cost-efficient approximate multiplication, the first stage implements Mitchell's algorithm that performs the approximate multiplication using only two adders. The second stage adopts the exact multiplication to compensate for the error from the first stage by multiplying error terms and adding its truncated result to the final output. In our design, the low-cost multiplications in both stages can reduce hardware costs significantly and provide low relative errors by compensating for the error from the first stage. We apply our approximate multiplier to the convolutional neural network (CNN) inferences, which shows small accuracy drops with well-known pre-trained models for the ImageNet database. Therefore, our design allows low-cost CNN inference systems with high test accuracy.

Parallel Driven Power Supply with Low Cost Hot Swap Controller for Server (저가형 Hot Swap Controller를 가지는 병렬 구동 서버용 전원 장치)

  • Yi, KangHyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.738-744
    • /
    • 2018
  • This paper proposes a low cost hot swap operation circuit of a parallel operation power supply for servers. Hot swap function for server power system is essential in 24 hour operation system such as internet data center, server, factory and etc. Server power supplies used in internet data centers have two or more parallel operations with the hot swap operation. However, the cost of the power supply is high because the controller IC for hot swap operation is very expensive. Therefore, this paper proposes a parallel-operated power supply with a low-cost hot swap controller for servers. The proposed system can operate hot swap function by using discrete devices and reduce the cost by more than 50%. A 1.2kW prototype system is implemented to verify the proposed low cost hot swap controller.

Therapeutic lumbar facet joint nerve blocks in the treatment of chronic low back pain: cost utility analysis based on a randomized controlled trial

  • Manchikanti, Laxmaiah;Pampati, Vidyasagar;Kaye, Alan D.;Hirsch, Joshua A.
    • The Korean Journal of Pain
    • /
    • v.31 no.1
    • /
    • pp.27-38
    • /
    • 2018
  • Background: Related to escalating health care costs and the questionable effectiveness of multiple interventions including lumbar facet joint interventions, cost effectiveness or cost utility analysis has become the cornerstone of evidence-based medicine influencing coverage decisions. Methods: Cost utility of therapeutic lumbar facet joint nerve blocks in managing chronic low back pain was performed utilizing data from a randomized, double-blind, controlled trial with a 2-year follow-up, with direct payment data from 2016. Based on the data from surgical interventions, utilizing the lowest proportion of direct procedural costs of 60%, total cost utility per quality adjusted life year (QALY) was determined by multiplying the derived direct cost at 1.67. Results: Patients in this trial on average received $5.6{\pm}2.6$ procedures over a period of 2 years, with average relief over a period of 2 years of $82.8{\pm}29.6$ weeks with $19{\pm}18.77$ weeks of improvement per procedure. Procedural cost for one-year improvement in quality of life showed USD $2,654.08. Estimated total costs, including indirect costs and drugs with multiplication of direct costs at 1.67, showed a cost of USD $4,432 per QALY. Conclusions: The analysis of therapeutic lumbar facet joint nerve blocks in the treatment of chronic low back pain shows clinical effectiveness and cost utility at USD $2,654.08 for the direct costs of the procedures, and USD $4,432 for the estimated overall cost per one year of QALY, in chronic persistent low back pain non-responsive to conservative management.

Low-income Households' Experiences and Perception of Home Energy Cost Burdens in Cheongju, South Korea (청주시 저소득 가구의 가정 에너지 비용 부담 경험과 인식)

  • Lee, Hyun-Jeong
    • Journal of the Korean housing association
    • /
    • v.26 no.5
    • /
    • pp.79-87
    • /
    • 2015
  • This study explored low-income households' experiences and perception of home energy cost burdens and determinants of the perceived home energy cost burdens. Between March and July 2014, a questionnaire survey was administered in Cheongju, South Korea. Among the 434 useable responses collected, responses from 218 households with monthly income less than 2,500,000 Korean Won (KRW) were compared with those of 216 households with higher incomes. The main findings are as follows. In the past three years, more than 10 percent of low-income households had had their electricity cut off; 5.7 percent had had their city gas cut off. To pay for their home energy expenses, nearly 70 percent of the low-income households had had to limit their heating, cooling or spending for other necessities; 38.3 percent had to borrow money. Low-income households reported more problems paying for home energy than higher-income households did. Households with more negative evaluation of rainwater leak, no one staying at home all day, monthly income less than 1,500,000 KRW and householders in their 40s and 50s tended to perceive a heavier home energy cost burden. Finally, the most popular support programs were fuel assistance and discounts on energy bills.

Empirical Study on Customer Satisfaction and Intention to Reuse in Chinese Low Cost Carrier Industry (중국 저가항공사 서비스 만족도 및 재이용 의도에 관한 연구)

  • Tuohuti, Yusufu;Kim, Myoung-Soo
    • Asia-Pacific Journal of Business
    • /
    • v.11 no.4
    • /
    • pp.167-176
    • /
    • 2020
  • Purpose - In this study, we tried to find that the relationship between the perception of customers on the airline service quality, customer satisfaction, and intention to reuse in Chinese low-cost carriers industry. Design/methodology/approach - We conducted the empirical study for hypotheses testing using the survey data of experienced users in Chinese low-cost carriers service. In this study, reliability and factor analysis were conducted using SPSS 26.0, the path analysis was performed using AMOS 24. Findings - We found that the customer's perception of aviation operation, reservation/ ticketing, online information service provided by Chinese low-cost carriers are positively associated with customer satisfaction. In addition, it was confirmed that customer satisfaction is positively related to the intention to reuse. Research implications or Originality - Based on the results of analysis, it was confirmed that the basic sub-services of the airline are also important in the low-cost carriers services market.

A Study on the Low Cost Testing System Development of the Low Speed and High Torque Harsh Reducer (저속 고토크 가혹감속기의 저비용 테스트 시스템 개발에 관한 연구)

  • Park, Taehyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.379-386
    • /
    • 2022
  • The goal of this research is to verify a performance test system for a low speed, high torque, and harsh reducer at low cost. The reducer rotates a cooling fan with a diameter of 10 meters, in a high temperature (50℃) cooling tower in a geothermal power plant. It requires about 500 kgf·m torque and 47.75 kW power to rotate the fan at a maximum power condition. An expensive dynamometer is commonly used for performance test of a motor or a reducer. In this paper, a low cost system is developed using a hydraulic pump as a load unit to generate torque instead of a dynamometer. We accurately calculated the required power, the flow meter, and the pressure of the pump, and selected to design and optimize the system at minimal cost. The system also applied another reverse reducer and a gearbox to increase the rotational speed and to reduce the torque from the low speed and high torque target reducer. This allows low-cost systems to be built using inexpensive components. The developed system was able to successfully measure the high torque and the low rotational speed of the target reducer at high temperature.