• 제목/요약/키워드: Low cardiac output syndrome

검색결과 118건 처리시간 0.026초

CarboMEdics 기계판막을 이용한 심장판막 치환술의 임상 연구 (Clinical Study of Prosthetic Heart Valve Replacement with CarboMedics.)

  • 장원기;구자홍;조중구;김공수
    • Journal of Chest Surgery
    • /
    • 제33권1호
    • /
    • pp.45-50
    • /
    • 2000
  • Background: The CarboMedics prosthetic heart valve was produced in an attempt to improve the existing valve designs and was especially concerned with easily the implantation and further reduction of turbulence. Precise positioning of the valve in situ was achieved by the abilityof the valve to rotate relative to the sewing ring. Improved monitoring is possible due to increased radiopacity and the dacron sewing ring is coated with carbon to reduce pannus overgrowth. The leaflets have an opening angle of 78 degrees that apparently allows a rapid synchronous closure The aim of this study was to analyze the clinical performance of the CarboMedics valve prostheses(45 mitral 13 aortic and 7 double aortic-mitral valve replacement) were implanted in 65 patients(mean age 48.75$\pm$9.74 years) Result: The operative mortality was 3.1%(2/65) causes of death were low cardiac output syndrome. Total follow up was 1831 patient-months and mean follow up was 29.06$\pm$10.97 months/patient. No structural failure hemorrhage valve thrombosis and late death have been observed. Embolism occurred at a rate of 0.65%/Patient-year. Actuarial survival and thrombo-mbolism free rate at 36 months were 96.9% and 98.4% respectively. Consclusions: The CarboMedics valve stands for low valve related complicatons.

  • PDF

내흉동맥과 요골동맥을 이용한 관상동맥우회술의 조기 결과 (Early result of Coronary Artery Bypass Grafting Using the Internal Thoracic and the Radial Arteries)

  • 나찬영;이영탁
    • Journal of Chest Surgery
    • /
    • 제32권10호
    • /
    • pp.891-896
    • /
    • 1999
  • Increasing interest in the use of arterial conduites is based on the better patency of the internal thoracic artery(ITA) than the saphenous vein graft and the hope that other arterial conuits will perform similarly over the long term. Material and Method: Between May 1997 and July 1998, 43 patients underwent coronary artery bypass grafting with ITA and the radial artery(RA). There were 28 men and 15 women with a mean age of 61.5 years(range, 35 to 78). In 43 patents, 30 bilateral ITA(including 7 diabetes mellitus, 5 more older 70 years), 8 bilateral ITA only, 2 left ITA and both RA, 11 left ITA and left RA and 22 both ITA and left RA were used. Result: There was 1 hospital mortality. Of the 42 patients alive, 39 patients are asymptomatic. Postoperative complications were postoperative bleeding in 1 patients, and low cardiac output syndrome in 3. Follow-up angiography was performed in 5 patients after the operation(mean 3 months), and all ITA & RA grafts showed excellent results. Conclusion: We conclude that complete arterial revascularization with internal thoracic artery and radial artery is technically feasiale with low mortality and morbidity, and but long term follow-up is needed.

  • PDF

성인 20 세 이상 활로 4징증의 수술성적 (Surgical Correction of Tetralogy of Fallot in Adults over 20 Years of Age)

  • 정윤섭
    • Journal of Chest Surgery
    • /
    • 제23권2호
    • /
    • pp.253-259
    • /
    • 1990
  • Between January, 1970 and August, 1989, a total of 81 patients whose age were more than 20 years of life, received total correction for tetralogy of Fallot. This report analyzed 70 patients among them and excluded the remaining 11 patients whose clinical data could not be found. Their mean age was 25.750.39 years[range 20 \ulcorner50]. The clinical manifestations were cyanosis and clubbing [64 pts], frequent URI[40 pts], anoxic spell [19 pts], infective endo-carditis[4 pts], brain abscess[3 pts], pulmonary tuberculosis[3 pts] and CHF, chest tightness, nephrotic syndrome, left hemiplegia, and tamponade. The types of right ventricular outflow tract obstruction were combined[46 pts], pure infundibular [21 pts] and pure valvular[3 pts]. Associated cardiovascular anomalies were PFO [27 pts], ASDi8 pts], LSVC[8 pts], aortic regurgitation [5 pts], right aortic arch, coronary artery anomalies, PDA and dextrocardia. Hospital mortality was 5.7%. The causes of death ware low cardiac output [2 pts], aggravation of CRF[1 pts] and brain damage[1 pts]. There was one late death because of residual intracardiac shunt and congestive heart failure. During the follow-up period, 16 patients were lost and the remaining 49 patients were asymptomatic and leading normal lives. Residual intracardiac shunt was detected in 5 patients with radionuclide single pass study but all of them had Qp / Qs ratio less than 1.5.

  • PDF

변형 Fontan 수술의 임상적 고찰8 (Clinical Experiences of Modified Fontan Operation in 8 cases)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • 제20권3호
    • /
    • pp.536-543
    • /
    • 1987
  • The Fontan procedure was physiological correction which was initially applied to tricuspid atresia. We had used the modified Fontan operation in 8 cases at National Medical Center, Seoul, from Aug. 1984 to Oct. 1986. Age range was 20 months to 15 years [mean: 9 years] and male: female ratio was 5:3. 5 patients had tricuspid atresia [lb: 2 cases, Ic: 1 case, lib: 1 case, & llc: 1 case], 2 Patients had univentricular heart of left ventricular type, and one patient had transposition of great arteries with complete endocardial cushion defect. The operative principle was direct anastomosis between right atrium and pulmonary artery, whether main pulmonary artery or right pulmonary artery without any conduits. Postoperatively all patients needed high central venous pressure for adequate hemodynamic status in both survival [20-24 CmH2O] and mortality groups [20-24 CmH2O]. The fatal complications were as follows: empyema with bronchopleural fistula [1 case], bleeding tendency & brain damage [1 case], low cardiac output syndrome & acute renal failure [2 cases], and right to left shunt of unknown origin [1 case]. There were 5 hospital deaths; 3 of 5 tricuspid atresia patients, 1 of 2 univentricular heart patients, and 1 of 1 transposition of great arteries with complete endocar4ial cushion defect patient. The overall mortality was 62.5%. 3 survivors were nearly compatible with Choussat & Fontan criteria. Thus appropriate patient selection and experienced surgical technique were required for good results.

  • PDF

Polytetrafluoethylene 인조혈관을 이용한 좌쇄골하동맥-좌폐동맥단락술에 관한 연구 (A study on left subclavian artery-left pulmonary artery shunt operation using polytetrafluoroethylene [PTFE])

  • 조중구;김근호
    • Journal of Chest Surgery
    • /
    • 제16권1호
    • /
    • pp.91-96
    • /
    • 1983
  • A study was carried out to observe the clinical progress and results after modified Blalock-Taussing shunts on II patients with cyanotic complex heart diseases unsuitable for corrective surgery. The operation was performed by interposing a vascular prosthesis [PTEE] between the left subclavian artery and the left pulmonary artery. Vascular prostheses larger than the diameter of left subclavian artery were selected. The results were as follows: 1. The postoperative courses in 10 patients were uneventful without any complications. One patient died of low cardiac output syndrome immediate postoperatively. 2. The average value of RBC count before operations was 751.2291.68 [xl00]/cubic mm. It was decreased to 588.11 90.45 [xl 0,000]/cubic mm. After the operation. 3. The average value of Hemoglobin before operations was 20.07 3.01 mg/dl. The value was decreased to 15.361.68mg/dl after the operation. 4. The value of Hematocrit before operations was 62.878.89%. The value was decreased to 49.6 5.84% 5. Patency after the shunt operations using PTFE was good for maximal 16 months follow-up period. 6. The physiological impairment like anoxic spells, degree of cyanosis and other clinical symptoms were markedly improved after the shunt operations. Although a longer follow-up seems to be necessary to assess the validity of these shunts, the early results were encouraging.

  • PDF

과량수혈이 혈역학에 미치는 영향 (Hemodynamic effects of induced overtransfusion of blood in dogs)

  • 기노석
    • Journal of Chest Surgery
    • /
    • 제17권3호
    • /
    • pp.418-423
    • /
    • 1984
  • Appreciation of the large volume deficits which may occur in surgical or trauma patients due to blood loss has led to vigorous transfusion techniques designed to overt hypovolemic shock and ischemic damage to vital organs which may develop in minutes during the hypovolemic state. In a significant proportion of patients treated with massive rapid blood or fluid transfusion, hypervolemia occurs and life threatening pulmonary edema may develop. Especially, hypervolemia may occur during transfusion for preventing development of the so-called low output syndrome following cardiac surgery. However, the most effective indicator which reveals the adequate level of transfusion is not settled yet. The present study was aimed to compare the effectiveness of the indicators suggested thus far and to determine the most sensitive one. Eight dogs were experimentally studied in terms of left atrial pressure, pulmonary arterial systolic pressure, central venous pressure, mean systemic arterial pressure and heart rate before and after induced hypervolemia with infusion of 600ml heparinized homologous blood. Immediately after induced overtransfusion of the blood, pulmonary arterial systolic pressure increased 75.0%, in omparison with the control before transfusion, left atrial pressure 58.8%, central venous pressure 44.6%, and mean systemic arterial pressure 10.1%, one hour after transfusion, pulmonary arterial systolic pressure 40.0%, left atrial pressure 21.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, respectively. Heart rate showed no significant change throughout the experiment. These result suggested that the changes of the pulmonary arterial systolic pressure is the most sensitive indicator for detection of hypervolemia during blood transfusion.

  • PDF

심근보호에 대한 임상적 고찰 (Clinical study of myocardial preservation)

  • 조재일;이영균
    • Journal of Chest Surgery
    • /
    • 제17권4호
    • /
    • pp.557-564
    • /
    • 1984
  • Of the valve replacement patients operated between 1983 and June, 1984, 75 patients need more than 60 minutes of aortic cross-clamping time. 42 patients performed single valve replacement [35 MVR, 7 AVR with or without TAP] and remainder needs double valve replacement with or without TAP. The average aortic clamping time was 95.1 minutes. They need 30 minutes more extra-corporeal circulation time than aortic clamping time. The patients were divided into two groups by usage of cardioplegic solution. Group I [n=31] with Bretschneider solution and group II with potassium cardioplegic solution [M.G.H. modification] were analyzed by extra-corporeal circulation data,/CG and Echocardiography findings, and clinical data. There was no difference between two groups in Bivon addition amounts [cc/kg] and E.F. and S.F. by echocardiography, group I need 1 more electrocardioversion to convert sinus rhythm postoperatively. Also no difference could be found in patients whose preoperative C.I. was above 2.0 between two group. But significant postoperative decrease in E.F. was found in group I whose preoperative C.I. was below 2.0. Relatively longer ECC time was also needed in same group. Ischemic changes in ECG and low cardiac output syndrome was, however more prevalent in groupII. As a whole, the clinical data was satisfactory with both cardioplegic solution in clinical practice.

  • PDF

Chest Wall Reconstruction with a Transverse Rectus Abdominis Musculocutaneous Flap in an Extremely Oversized Heart Transplantation

  • Yim, Ji Hong;Eom, Jin Sup;Kim, Deok Yeol
    • Archives of Reconstructive Microsurgery
    • /
    • 제23권2호
    • /
    • pp.89-92
    • /
    • 2014
  • An 8-year-old girl diagnosed with dilated cardiomyopathy and Russell-Silver syndrome was admitted to our pediatric intensive care unit due to low cardiac output and multiple-organ dysfunction. The patient was placed on the heart transplant waiting list and extracorporeal membrane oxygenation was performed as a bridge to transplantation. After 17 days, heart transplantation was performed. The donor was a 46-year-old female (weight, 50 kg; height, 150 cm). The donor:recipient weight ratio was 3.37:1. Because the dimension and volume of the recipient's thoracic cage were insufficient, the sternum could not be closed. Nine days after transplantation, the patient underwent delayed sternal closure. To obtain adequate space, we left the sternum 4.5 cm apart from each margin using four transverse titanium plates. A transverse rectus abdominis musculocutaneous flap was chosen to cover the wound. Due to the shortage of donors, a size-mismatched pediatric heart transplantation is sometimes unavoidable. Closure of the opened sternum of a transplant recipient can be challenging. Sternal reconstruction after an extremely oversized heart transplantation with transverse titanium plate fixation and a musculocutaneous flap can effectively achieve sternal closure and stability.

Bridge to Transplantation with a Left Ventricular Assist Device

  • Jung, Jae-Jun;Sung, Ki-Ick;Jeong, Dong-Seop;Kim, Wook-Sung;Lee, Young-Tak;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • 제45권2호
    • /
    • pp.116-119
    • /
    • 2012
  • A 61-year-old female patient was diagnosed with dilated cardiomyopathy with severe left ventricle dysfunction. Two days after admission, continuous renal replacement therapy was performed due to oliguria and lactic acidosis. On the fifth day, an intra-aortic balloon pump was inserted due to low cardiac output syndrome. Beginning 4 days after admission, she was supported for 15 days thereafter with an extracorporeal left ventricular assist device (LVAD) because of heart failure with multi-organ failure. A heart transplant was performed while the patient was stabilized with the LVAD. She developed several complications after the surgery, such as cytomegalovirus pneumonia, pulmonary tuberculosis, wound dehiscence, and H1N1 infection. On postoperative day 19, she was discharged from the hospital with close follow-up and treatment for infection. She received follow-up care for 10 months without any immune rejection reaction.

St. Jude 기계판막의 단기및 중기 성적 (Short-term and Intermediate-term Follow-up After Valve Replacement with the St.Jude Medical Prosthesis)

  • 조범구
    • Journal of Chest Surgery
    • /
    • 제25권1호
    • /
    • pp.57-65
    • /
    • 1992
  • St.Jude Medical cardiac valve replacement was performed in 322 patients: 191 had mitral, 58 had aortic, 72 had double valve and 3 had tricuspid valve replacement. Motality rate in early period was 2.8%[9 patients]. The most common cause of early death was low cardic output syndrome. Follow up extended from 1 to 90 months[mean: 34 months] in 292 patients among 313 in all surviving patients [93.6%]. There were thrombolic complications in eighteen patients. The probability of free from thromboembolism at 5 yerars in MVR, AVR and DVR were 84.7%, 91.8% and 90.2% respectively. And also, actuarial event free rate at 5 years in MVR, AVR and DVR were 80.1%, 82.2%, and 81.4% respectively. There were fourteen late death during follow up period: six from thromboembolism, one from hemorrhage and the others from non valve related -or unknown complications. The acturial survival rate at 5 years were 93.1% in mitral, 92.1% in aortic and 97.1% in double valve replacement. In conclusion, the performance of the St. Jude Mecanical valve compares most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF