• Title/Summary/Keyword: Low Temperature Generator

Search Result 142, Processing Time 0.024 seconds

Development of a divided-flow humidity generator and its use for studying low-temperature effects on radiosonde humidity sensors (분류식 습도 발생 장치 개발 및 라디오존데 습도센서 저온 효과 보정에 활용 연구)

  • Jang, Eun-Jeong;Lee, Young-Suk;Choi, Byung-Il;Choi, Yoonseuk;Lee, Sang-Wook
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.243-249
    • /
    • 2021
  • Humidity is an important physical quantity that is closely related with the quality of everyday life as well as the quality control of products in various industries. Here, we have developed a divided-flow type humidity generator of which humidity generation is faster than the saturator-based humidity generator in ppm level. The operation principle of the divided-flow humidity generator is first introduced. Then, the performance of the divided-flow humidity generator is verified by testing the radiosonde humidity sensor at low temperature. As a result, the humidity generated from the divided-flow humidity generator is consistent with the saturator-based precision humidity generator within 1.6% relative humidity in the range from 10% to 40% at -45 ℃. It is also found that the radiosonde humidity sensor shows measurement errors by 3% - 5% at -45 ℃ when it is only calibrated at room temperature. The response times of radiosonde humidity sensor using the divided-flow humidity generator are between about 2 and 9 minutes, whereas those by the saturator-based humidity generator are about 20 minutes. In this regard, the divided-flow humidity generator has a merit in terms of fast humidity changes for the calibration of radiosonde humidity sensors at low-temperatures.

Performance Experiment of Generator for Household Absorption Chiller and Heater (가정용 흡수식 냉난방기 개발을 위한 재생기 성능실험)

  • Yu, Sun-Il;Kwon, Oh-Kyung;Yoon, Jung-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1347-1354
    • /
    • 1999
  • Recently, the markets of the air conditioner are enlarging. The market size will reach 2.0 billion won in 2000. Electric heat pumps have been utilized as main residential air conditioners. especially in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes serious problem to the global environment such as global warming and ozone layer destruction. Absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the generator for absorption chiller and heater. Experiment was done with a high temperature generator, a low temperature generator, heat exchangers, a condenser and a solution tank. It was tested that the double effect series flow cycle with two kinds of solution cycle. Solution cycle B showed better than solution cycle A. Two kinds of heat exchanger were used, where one's heat transfer area is bigger than the other. Bigger one increased a little performance of absorption chiller and heater. But it was not economical. From this study, we got that the coefficient of performance(COP) is 0.82 and the capacity is 7.24 kW for an absorption chiller and heater.

Temperature Variation of Exhaust Gas in Diesel Generator for Low Pressure SCR (저압 SCR을 위한 디젤발전기 배기가스 온도 변화)

  • Hong, Chul Hyun;Lee, Chang Min;Lee, Sang Duk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.355-362
    • /
    • 2021
  • To facilitate low-pressure selective catalyst reduction (L.P SCR), a high exhaust-gas temperature of a four-stroke diesel engine for a ship's generator is required. This study aimed at reducing the exhaust-gas temperature by adjusting the valve open-close timing and fuel injection timing to satisfy the operating conditions of L.P SCR and prevent accidents associated with the generator engine due to high temperature. To lower exhaust-gas temperature, the angle of the camshaft was adjusted and the shim of the fuel injection pump was added. As a result, the maximum explosion pressure increased and the average of the turbocharger outlet temperature dropped. Considering the heat loss from the turbocharger outlet to the SCR inlet, the operation condition for L.P SCR was satisfied with 290 ℃. The study demonstrates that safe operation of a diesel generator can be achieved by lowering the exhaust-gas temperature.

Current-controllable saw-tooth waveform generator using OTA's (OTA를 이용한 전류-제어 톱니파 발생기)

  • 임동빈;정원섭;송재훈;김희준
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.177-180
    • /
    • 2001
  • A saw-tooth waveform generator with current-controllable frequency is described. The generator utilizes operational transconductance amplifiers as switching element. It features simple and wide sweep capability. The circuit built with commercially avaliable components exhibits good linearity of current to frequency and relatively low temperature sensitivity.

  • PDF

A study on the Design of a stable Substrate Bias Generator for Low power DRAM's (DRAM 의 저전력 구현을 위한 안정한 기판전압 발생기 설계에 관한 연구)

  • 곽승욱;성양현곽계달
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.703-706
    • /
    • 1998
  • This paper presents an efficient substrate-bias generator(SBG)for low-power, high-density DRAM's The proposed SBG can supply stable voltage with switching the supply voltage of driving circuit, and it can substitude the small capacitance for the large capacitance. The charge pumping circuit of the SBG suffere no VT loss and is to be applicable to low-voltage DRAM's. Also it can reduce the power consumption to make VBB because of it's high pumping efficiency. Using biasing voltage with positive temperature coefficient, VBB level detecting circuit can detect constant value of VBB against temperature variation. VBB level during VBB maintaining period varies 0.19% and the power dissipation during this period is 0.16mw. Charge pumping circuit can make VBB level up to -1.47V using VCC-1.5V, and do charge pumping operation one and half faster than the conventional ones. The temperature dependency of the VBB level detecting circuit is 0.34%. Therefore the proposed SBG is expected to supply a stable VBB with less power consumption when it is used in low power DRAM's.

  • PDF

Disinfective Properties and Ozone Concentrations in Water and Air from an Ozone Generator and a Low-temperature Dielectric Barrier Discharge Plasma Generator (오존발생기와 저온 유전체장벽 플라즈마를 이용한 오존 발생 및 살균력)

  • Lee, Young Sik;Jeon, Hyoung-Joo;Han, Hyung-Gyun;Cheong, Cheong-Jo
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.937-944
    • /
    • 2013
  • Ozone concentrations in water and air, and resulting disinfective properties, were measured following generation by either an ozone generator or a low-temperature dielectric barrier discharge plasma generator. In freshwater, ozone concentrations of 0.81 and 0.48 mg/L $O_3$ were observed after the ozone and plasma generators had been operated for five minutes, respectively. Higher levels of dissolved $O_3$ were attained more easily with the ozone generator. In seawater, both systems were capable of creating concentrations greater than 3.00 mg/L $O_3$ after 5minutes of operation. Higher ozone levels were attained more easily in seawater than in freshwater. Rates of bacterial sterilization in seawater after three minutes were 96% and 88%, using the plasma and ozone generators, respectively. In freshwater, higher concentrations of ozone were released into the atmosphere by the ozone generator than by the plasma generator. In creating equivalent levels of dissolved ozone in freshwater, the plasma generator released 4.5 times more ozone into the atmosphere than did the ozone generator. This shows that ozone generators are more effective than plasma generators for creating ozonated water. For the same concentration of dissolved ozone in seawater, more ozone was released into the atmosphere using the ozone generator than using the plasma generator. Therefore, with regard to air pollution, plasma generators seem to be less expensive than ozone generators.

Experimental Study on Thermal Insulation and Cooling for Rotor/Bearing Area in 500W Class Micro Gas Turbine Generator (500W급 마이크로 가스터빈 발전기 회전체-베어링부의 단열 및 냉각 성능에 대한 실험적 연구)

  • Park, Cheol Hoon;Choi, Sang Kyu;Ham, Sang Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.19-24
    • /
    • 2014
  • Development of long-term mobile energy sources for mobile robots or small-sized unmanned vehicles are actively increasing. The micro gas turbine generator (MTG) is a good candidate for this purpose because it has both of high energy density and high power density, and 500W class MTG is under development. The designed MTG can be divided into 2 main parts. One part consists of motor/ generator and compressor, and the other one consists of combustor, recuperator and turbine. 500W class MTG is designed to operate at ultra-high speed of 400,000 rpm in high turbine temperature over $700^{\circ}C$ to improve the efficiency. Because the magnetism of NdFeB permanent magnet for the motor/generator could be degraded if the temperature is over $150-200^{\circ}C$, MTG needs the thermal insulation to block the heat transfer from combustor/turbine side to motor/generator side. Moreover, the motor/generator is allocated to get the cooling effect from the rapid air flow by the compressor. This study presents the experimental results to verify whether the thermal insulator and air flow are effective enough to keep the motor/generator part in the low temperature less than $100^{\circ}C$. From the motoring test by using the high temperature test rig, it was confirmed that the motor/generator part could maintain the temperature less than $50^{\circ}C$ under the condition of 1.0 bar compressed air.

High accuracy, Low Power Spread Spectrum Clock Generator to Reduce EMI for Automotive Applications

  • Lee, Dongsoo;Choi, Jinwook;Oh, Seongjin;Kim, SangYun;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.6
    • /
    • pp.404-409
    • /
    • 2014
  • This paper presents a Spread Spectrum Clock Generator (SSCG) based on Relaxation oscillator using Up/Down Counter. The current is controlled by a counter and the spread spectrum of the Relaxation Oscillator. A Relaxation Oscillator with temperature compensation using the BGR and ADC is presented. The current to determine the frequency of the Relaxation Oscillator can be controlled. The output frequency of the temperature can be compensated by adjusting the current according to the temperature using the code that is the output from the ADC and BGR. EMI Reduction of SSCG is 11 dB, and Spread down frequency is 150 kHz. The current consumption is $600{\mu}A$ from 5V and the operating frequency is from 2.3 MHz to 5.75 MHz. The rate of change of the output frequency with temperature was approximately ${\pm}1%$. The SSCG is fabricated in a 0.35um CMOS process with active area $250um{\times}440um$.

A Triangular/Square Waveforms Generator Using Linear OTA's (선형 OTA를 이용한 삼각파/구형파 발생기)

  • 박상렬;박지만정원섭
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.663-666
    • /
    • 1998
  • A triangular/square waveforms generator with current controllable frequency is described. The genertor utilizes operational transconductance amplifiers as switching elements. The circuit built with commercially available components exhibits good linearity of current to frequency and relatively low temperature sensitivity.

  • PDF

Fuel-Rich Combustion Characteristic of a Combined Gas Generator (혼합식 가스발생기의 연료과농 연소특성)

  • Lee, Dongeun;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.7
    • /
    • pp.593-600
    • /
    • 2015
  • In this study, a combined hybrid rocket system is newly introduced which has characteristics of both gas generators and afterburner type hybrid rockets. In particular, a combined gas generator utilizing solid fuel and liquid/gas oxidizer was designed as a primary combustor of the system. Combustion tests were carried out with various equivalence ratio affected by parameters such as fuel length, oxidizer flow rate, fuel port diameter and fuel type. In general, fuel-rich gas generator produces low combustion gas temperature to meet the temperature requirement and the target temperature was transiently set less than 1600 K. Since it was found that controlling parameters showed limited effects on the change of equivalence ratio, mixture of $O_2$ and $N_2$ as an oxidizer was additionally introduced. As a result, a combined gas generator successfully produced combustion gas temperature of less than 1600 K Future studies will carry out more combustion tests to attain fuel-rich combustion gas temperature less than 1200 K, which was a temperature requirement of a gas generator system in the previous studies.