• 제목/요약/키워드: Low Temperature Generator

검색결과 142건 처리시간 0.023초

분류식 습도 발생 장치 개발 및 라디오존데 습도센서 저온 효과 보정에 활용 연구 (Development of a divided-flow humidity generator and its use for studying low-temperature effects on radiosonde humidity sensors)

  • 장은정;이영석;최병일;최윤석;이상욱
    • 센서학회지
    • /
    • 제30권4호
    • /
    • pp.243-249
    • /
    • 2021
  • Humidity is an important physical quantity that is closely related with the quality of everyday life as well as the quality control of products in various industries. Here, we have developed a divided-flow type humidity generator of which humidity generation is faster than the saturator-based humidity generator in ppm level. The operation principle of the divided-flow humidity generator is first introduced. Then, the performance of the divided-flow humidity generator is verified by testing the radiosonde humidity sensor at low temperature. As a result, the humidity generated from the divided-flow humidity generator is consistent with the saturator-based precision humidity generator within 1.6% relative humidity in the range from 10% to 40% at -45 ℃. It is also found that the radiosonde humidity sensor shows measurement errors by 3% - 5% at -45 ℃ when it is only calibrated at room temperature. The response times of radiosonde humidity sensor using the divided-flow humidity generator are between about 2 and 9 minutes, whereas those by the saturator-based humidity generator are about 20 minutes. In this regard, the divided-flow humidity generator has a merit in terms of fast humidity changes for the calibration of radiosonde humidity sensors at low-temperatures.

가정용 흡수식 냉난방기 개발을 위한 재생기 성능실험 (Performance Experiment of Generator for Household Absorption Chiller and Heater)

  • 유선일;권오경;윤정인
    • 대한기계학회논문집B
    • /
    • 제23권10호
    • /
    • pp.1347-1354
    • /
    • 1999
  • Recently, the markets of the air conditioner are enlarging. The market size will reach 2.0 billion won in 2000. Electric heat pumps have been utilized as main residential air conditioners. especially in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes serious problem to the global environment such as global warming and ozone layer destruction. Absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the generator for absorption chiller and heater. Experiment was done with a high temperature generator, a low temperature generator, heat exchangers, a condenser and a solution tank. It was tested that the double effect series flow cycle with two kinds of solution cycle. Solution cycle B showed better than solution cycle A. Two kinds of heat exchanger were used, where one's heat transfer area is bigger than the other. Bigger one increased a little performance of absorption chiller and heater. But it was not economical. From this study, we got that the coefficient of performance(COP) is 0.82 and the capacity is 7.24 kW for an absorption chiller and heater.

저압 SCR을 위한 디젤발전기 배기가스 온도 변화 (Temperature Variation of Exhaust Gas in Diesel Generator for Low Pressure SCR)

  • 홍철현;이창민;이상득
    • 해양환경안전학회지
    • /
    • 제27권2호
    • /
    • pp.355-362
    • /
    • 2021
  • L.P SCR의 촉매 반응을 위해 선박의 발전기용 4행정 디젤엔진의 배기가스 온도를 높게 설계 할 수밖에 없었다. 본 연구의 목적은 밸브개폐시기와 연료분사시기를 조정을 통한 배기가스의 온도 감소가 L.P SCR의 운전조건을 만족시키고 고온으로 인한 발전기 엔진의 사고를 예방하기 위함이었다. 배기가스 온도를 하강시키기 위해 캠샤프트의 각도를 조정하고 연료분사펌프의 Shim을 추가하였다. 그 결과 최대폭발압력은 12.8 bar 증가하였고 터보차저 출구온도 평균값은 13.3 ℃ 하강하였다. 터보차저 출구에서 SCR 입구까지의 열손실을 감안하더라도 L.P SCR 운전조건인 SCR 챔버 입구 온도인 290 ℃를 만족하였다. 배기가스 온도 하강을 통해 디젤발전기의 안전운전이 가능하게 한 연구였다.

OTA를 이용한 전류-제어 톱니파 발생기 (Current-controllable saw-tooth waveform generator using OTA's)

  • 임동빈;정원섭;송재훈;김희준
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.177-180
    • /
    • 2001
  • A saw-tooth waveform generator with current-controllable frequency is described. The generator utilizes operational transconductance amplifiers as switching element. It features simple and wide sweep capability. The circuit built with commercially avaliable components exhibits good linearity of current to frequency and relatively low temperature sensitivity.

  • PDF

DRAM 의 저전력 구현을 위한 안정한 기판전압 발생기 설계에 관한 연구 (A study on the Design of a stable Substrate Bias Generator for Low power DRAM's)

  • 곽승욱;성양현곽계달
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.703-706
    • /
    • 1998
  • This paper presents an efficient substrate-bias generator(SBG)for low-power, high-density DRAM's The proposed SBG can supply stable voltage with switching the supply voltage of driving circuit, and it can substitude the small capacitance for the large capacitance. The charge pumping circuit of the SBG suffere no VT loss and is to be applicable to low-voltage DRAM's. Also it can reduce the power consumption to make VBB because of it's high pumping efficiency. Using biasing voltage with positive temperature coefficient, VBB level detecting circuit can detect constant value of VBB against temperature variation. VBB level during VBB maintaining period varies 0.19% and the power dissipation during this period is 0.16mw. Charge pumping circuit can make VBB level up to -1.47V using VCC-1.5V, and do charge pumping operation one and half faster than the conventional ones. The temperature dependency of the VBB level detecting circuit is 0.34%. Therefore the proposed SBG is expected to supply a stable VBB with less power consumption when it is used in low power DRAM's.

  • PDF

오존발생기와 저온 유전체장벽 플라즈마를 이용한 오존 발생 및 살균력 (Disinfective Properties and Ozone Concentrations in Water and Air from an Ozone Generator and a Low-temperature Dielectric Barrier Discharge Plasma Generator)

  • 이영식;전형주;한형균;정정조
    • 한국환경과학회지
    • /
    • 제22권8호
    • /
    • pp.937-944
    • /
    • 2013
  • Ozone concentrations in water and air, and resulting disinfective properties, were measured following generation by either an ozone generator or a low-temperature dielectric barrier discharge plasma generator. In freshwater, ozone concentrations of 0.81 and 0.48 mg/L $O_3$ were observed after the ozone and plasma generators had been operated for five minutes, respectively. Higher levels of dissolved $O_3$ were attained more easily with the ozone generator. In seawater, both systems were capable of creating concentrations greater than 3.00 mg/L $O_3$ after 5minutes of operation. Higher ozone levels were attained more easily in seawater than in freshwater. Rates of bacterial sterilization in seawater after three minutes were 96% and 88%, using the plasma and ozone generators, respectively. In freshwater, higher concentrations of ozone were released into the atmosphere by the ozone generator than by the plasma generator. In creating equivalent levels of dissolved ozone in freshwater, the plasma generator released 4.5 times more ozone into the atmosphere than did the ozone generator. This shows that ozone generators are more effective than plasma generators for creating ozonated water. For the same concentration of dissolved ozone in seawater, more ozone was released into the atmosphere using the ozone generator than using the plasma generator. Therefore, with regard to air pollution, plasma generators seem to be less expensive than ozone generators.

500W급 마이크로 가스터빈 발전기 회전체-베어링부의 단열 및 냉각 성능에 대한 실험적 연구 (Experimental Study on Thermal Insulation and Cooling for Rotor/Bearing Area in 500W Class Micro Gas Turbine Generator)

  • 박철훈;최상규;함상용
    • 한국유체기계학회 논문집
    • /
    • 제17권3호
    • /
    • pp.19-24
    • /
    • 2014
  • Development of long-term mobile energy sources for mobile robots or small-sized unmanned vehicles are actively increasing. The micro gas turbine generator (MTG) is a good candidate for this purpose because it has both of high energy density and high power density, and 500W class MTG is under development. The designed MTG can be divided into 2 main parts. One part consists of motor/ generator and compressor, and the other one consists of combustor, recuperator and turbine. 500W class MTG is designed to operate at ultra-high speed of 400,000 rpm in high turbine temperature over $700^{\circ}C$ to improve the efficiency. Because the magnetism of NdFeB permanent magnet for the motor/generator could be degraded if the temperature is over $150-200^{\circ}C$, MTG needs the thermal insulation to block the heat transfer from combustor/turbine side to motor/generator side. Moreover, the motor/generator is allocated to get the cooling effect from the rapid air flow by the compressor. This study presents the experimental results to verify whether the thermal insulator and air flow are effective enough to keep the motor/generator part in the low temperature less than $100^{\circ}C$. From the motoring test by using the high temperature test rig, it was confirmed that the motor/generator part could maintain the temperature less than $50^{\circ}C$ under the condition of 1.0 bar compressed air.

High accuracy, Low Power Spread Spectrum Clock Generator to Reduce EMI for Automotive Applications

  • Lee, Dongsoo;Choi, Jinwook;Oh, Seongjin;Kim, SangYun;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제3권6호
    • /
    • pp.404-409
    • /
    • 2014
  • This paper presents a Spread Spectrum Clock Generator (SSCG) based on Relaxation oscillator using Up/Down Counter. The current is controlled by a counter and the spread spectrum of the Relaxation Oscillator. A Relaxation Oscillator with temperature compensation using the BGR and ADC is presented. The current to determine the frequency of the Relaxation Oscillator can be controlled. The output frequency of the temperature can be compensated by adjusting the current according to the temperature using the code that is the output from the ADC and BGR. EMI Reduction of SSCG is 11 dB, and Spread down frequency is 150 kHz. The current consumption is $600{\mu}A$ from 5V and the operating frequency is from 2.3 MHz to 5.75 MHz. The rate of change of the output frequency with temperature was approximately ${\pm}1%$. The SSCG is fabricated in a 0.35um CMOS process with active area $250um{\times}440um$.

선형 OTA를 이용한 삼각파/구형파 발생기 (A Triangular/Square Waveforms Generator Using Linear OTA's)

  • 박상렬;박지만정원섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.663-666
    • /
    • 1998
  • A triangular/square waveforms generator with current controllable frequency is described. The genertor utilizes operational transconductance amplifiers as switching elements. The circuit built with commercially available components exhibits good linearity of current to frequency and relatively low temperature sensitivity.

  • PDF

혼합식 가스발생기의 연료과농 연소특성 (Fuel-Rich Combustion Characteristic of a Combined Gas Generator)

  • 이동언;이창진
    • 한국항공우주학회지
    • /
    • 제43권7호
    • /
    • pp.593-600
    • /
    • 2015
  • 본 논문은 하이브리드 로켓 성능향상을 위하여 가스발생기형과 후방 연소형 개념을 결합한 혼합형 하이브리드 로켓을 제안하고 있다. 특히 고체 추진제를 사용하는 기존의 가스발생기와 달리, 고체연료와 액체/기체 산화제를 적용한 혼합식 가스발생기를 제안하였으며 혼합식 가스발생기의 연료과농 연소특성을 확인하기 위하여 연료 길이, 산화제 유량, 연료 내경 그리고 연료 종류를 변화하며 연소가스 온도 변화를 측정하였다. 그러나 이들 인자 변화에 의한 온도변화가 매우 제한적이므로 또 다른 인자로 $O_2$$N_2$를 혼합한 혼합산화제를 사용하였다. 이때 가스발생기의 연소가스 온도의 요구조건은 1600 K이하로 설정하였으며 연소 시험에서 혼합식 가스발생기는 온도조건을 만족하는 연료과농 연소가스가 생성되었음을 확인하였다. 그러나 온도에 따른 검댕의 발생특성과 다른 이전 연구들에서 제시하는 가스발생기 연소가스 온도 요구조건이 1200 K이하임을 고려할 때, 최종적으로 이 조건을 만족하는 연료과농 연소가스를 생성할 계획이다.