• 제목/요약/키워드: Low Power Management

검색결과 806건 처리시간 0.038초

발전비용의 부하역률 감도와 종합비용을 활용한 효과적인 역률개선 방안 연구 (A Study on the Effective Enhancement of the Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost and Integrated Costs)

  • 이병하;오민혁;김정훈;심건보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.284-286
    • /
    • 2003
  • The low load power factor causes various problems such as the Increase of the power loss and the voltage instability. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power troublesome, from which the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost and integrated costs are used for determining the locations and capacities of reactive power compensation devices effectively and for enhancing the load power factor appropriately. It is shown through the application to a small-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

견마로봇의 전력제어 및 최적 운용에 대한 연구 (Study on Power Control and Optimal Management for Dog-Horse Robot)

  • 강태하;허진욱;김준;강신천
    • 한국군사과학기술학회지
    • /
    • 제13권3호
    • /
    • pp.343-348
    • /
    • 2010
  • Recently, unmanned electric vehicles are increasingly interested among all of the world since they can provide low exhaust gas, high efficiency and high mobility. To exploit their silent maneuver and high mobility, unmanned electric vehicles have been developed since early 1980's for military. However, it is not easy to design and control a power system satisfying operating duration and mobility performance requirements based on various mission profiles for military use under the conditions of limited space and weight. Moreover it is also necessary to prevent over-charge, over-discharge and voltage unbalance between cells of battery to secure high voltage battery which is serially connected with muti-cells. In this paper, we presents power control and optimal management method for the dog-horse robot which adopts a electric power system and suggests a guide-line to manage and control to secure high voltage battery.

The Strategy of Wireless Power Transfer for Light Rail Transit By Core Technologies Analysis Based on Text Mining

  • Meng, Xiang-Yu;Han, Young-Jae;Eum, Soo-Min;Cho, Sung-Won
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권11호
    • /
    • pp.193-201
    • /
    • 2018
  • In this paper, we extracted relevant patent data and conducted statistical analysis to understand the technical development trend related to Wireless Power Transfer (WPT) for Light Rail Transit (LRT). Recently, with the development of WPT technologies, the Light Rail Transit (LRT) industry is concentrating on applying WPT to the power supply system of trains because of their advantages compared wired counterpart, such as low maintenance cost and high stability. This technology is divided into three areas: wireless feeding and collecting technology, high-frequency power converter technology and orbital and infrastructure technology. From each specific area, key words in patent document were extracted by TF-IDF method and analyzed by social network. In the keyword network, core word of each specific technology were extracted according to their degree centrality. Then, the multi-word phrases were also built to represent the concept of core technologies. Finally, based on the analysis results, the development strategies for each specifics technical area of WPT in LRT filed will be provided.

농업저수지 자동 수위관측기 개발 - 저전력 원격제어 수위관측기 중심 - (Development of Automatic Water Level Measurement System for the Irrigation Reservoir - Study on Low Power and Remote Controlled Water Level Measurement System -)

  • 김진택;주욱종;최승철
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.491-494
    • /
    • 2003
  • An Automatic Water Level Measurement System has been developed in this study. It has the characteristics that it use lower power and solar power and it has the ability of sending data and remote-controlled by wireless MODEM this system was set up in the experimental site and was tested. Also, the management system for the water level data has been developed and will be used by instruments administrating reservoirs.

  • PDF

무선망에서 기지국의 전력소모에 대한 운영 방안 (A operation scheme to the power consumption of base station in wireless networks)

  • 박상준
    • 한국정보통신학회논문지
    • /
    • 제24권2호
    • /
    • pp.285-289
    • /
    • 2020
  • 무선 네트워크의 계층적 구성은 다양한 네트워크 환경을 지원하기 위해 제공된다. 기지국에서는 두 가지 시스템 상태가 기본적으로 고려될 수 있으며, 이에 대해 액티브와 슬립 모드 사이에서 상태 전이가 발생할 수 있다. 그러므로 에너지 사용을 줄이기 위하여 저전력의 시스템 운영 관리가 기지국 시스템에 고려되어야 한다. 따라서 본 논문에서는 시스템 관리를 다루기 위해 Discontinuous Reception (DRX) 분석 모델을 고려한다. DRX 모델을 통하여 기지국 시스템의 운영에 대한 분석 방안을 제시하며 에너지 소비를 위한 저전력 강도를 살펴본다. 또한 시스템 상태에서 기지국의 저전력 소모에 대한 성능을 분석하기 위해 무선 자원 요구와 서비스 호 도착의 운영이 고려되며, 이를 위하여 유한 마르코프 시스템 모델을 사용하였다.

원형 좌표계를 이용한 센서네트워크 키 관리 기법 (Management Scheme of Sensor Network using Circular Coordinates)

  • 홍성식;유황빈
    • 융합보안논문지
    • /
    • 제6권2호
    • /
    • pp.71-80
    • /
    • 2006
  • 센서네트워크는 매우 제한된 자원을 갖는 작은 노드들로 구성되어 온도, 진동 등의 지역적 정보를 수집하고 통신망을 통하여 이들 정보를 제공한다. 센서네트워크는 일반적으로 매우 작고 제한적인 자원을 갖는 노드들로 구성되므로 이러한 노드들에 보안 서비스를 추가하는 것은 상당히 어려운 문제이다. 센서네트워크의 안정성을 위해서는 일반 네트워크 노드들에 비하여 보다 더 효율적인 키 관리 기법이 필요하다. 본 논문에서는 원형 좌표계를 이용한 위치 정보를 기반으로 키 관리하는 기법을 제시한다. 원형좌표계의 원점을 중심으로 노드와 노드간의 상대적인 위치 정보를 이용하여 키를 생성하였다. 이러한 방법은 대칭적 위치 구조에 의해 키 생성이 다른 방법에 비하여 간결하면서도 효율적임을 보였다.

  • PDF

VRFB-LFPB 하이브리드 배터리 기반의 ESS 개발에 관한 연구 (Development of ESS Based on VRFB-LFPB Hybrid Batteries)

  • 천영식;박진수;유진호;이진
    • 한국전기전자재료학회논문지
    • /
    • 제31권1호
    • /
    • pp.61-67
    • /
    • 2018
  • High-power lithium batteries are suitable for equipment with high power output needs, such as for ESS's initial start-up. However, their management cost is increased by the installation of air-conditioning to minimize the risk of explosion due to internal temperature rise and also by a restriction on the number of charge/discharge cycles. High-capacity flow batteries, on the other hand, have many advantages. They can be used for over 20 years due to their low management costs, resulting from no risk of explosion and a high number of charge/discharge cycles. In this paper, we propose an ESS based on hybrid batteries that uses a lithium iron phosphate battery (LiFePO) at the initial startup and a vanadium redox flow battery (VRFB) from the end of the transient period, with a bi-directional PCS to operate two batteries with different DC voltage levels and using an efficient energy management control algorithm.

Single-Phase Multilevel PWM Inverter Based on H-bridge and its Harmonics Analysis

  • Choi, Woo-Seok;Nam, Hae-Kon;Park, Sung-Jun
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1227-1234
    • /
    • 2015
  • The efficient electric power demand management in electric power supply industry is currently being changed by distributed generation. Meanwhile, small-scale distributed generation systems using renewable energy are being constructed worldwide. Several small-scale renewable distributed generation systems, which can supply electricity to the grid at peak load of the grid as per policy such as demand response programs, could help in the stability of the electric power demand management. In this case, the power quality of the small-scale renewable distributed generation system is more significant. Low prices of power semiconductors and multilevel inverters with high power quality have been recently investigated. However, the conventional multilevel inverter topology is unsuitable for the small-scale renewable distributed generation system, because the number of devices of such topology increases with increasing output voltage level. In this paper, a single-phase multilevel inverter based on H-bridge, with DC_Link divided by bi-directional switches, is proposed. The proposed topology has almost half the number of devices of the conventional multilevel inverter topology when these inverters have the same output voltage level. Double Fourier series solution is mainly used when comparing PWM output harmonic components of various inverter topologies. Harmonic components of the proposed multilevel inverter, which have been analyzed by double Fourier series, are compared with those of the conventional multilevel inverter. An inverter prototype is then developed to verify the validity of the theoretical analysis.

배전계통의 역률보상 콘덴서의 최적 위치 및 용량 산정 (The Optimal Condenser Position & Capacity for Power Factor Compensation in Distribution System)

  • 장정태;전영수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1190-1197
    • /
    • 1999
  • The management of power factor(PF) in the distribution line is treated according to the measurement a month about the feeder unit at the substation. In Korea, we have not researched into power factor in distribution system due to it's less weight. The reactive power in advanced countries is controlled automatically by the compensative condenser switch on/off under the monitoring. This paper first presents the optimal condenser position and proper capacity by lagrangue factor ${\lambda}_{Q}$ which is the line loss index about reactive power unit. Therefore, the largest ${\lambda}_{Q}$ node is the condenser injection point and we find out the best condenser capacity when the line loss is saturated by the moderation of condenser volume. By this method, we suggest 0.6% uprising PF by injection of 15 kVA condenser. Additionally, PF is analysed into 5 areas; large city, middle city, small city, farm village, fishing village by the use of Power Platform which is classified the same concept of the low load management in KEPCO. Two feeders of each area are selected by the worst results of PF in specified areas.

  • PDF

Active Distribution System Planning for Low-carbon Objective using Cuckoo Search Algorithm

  • Zeng, Bo;Zhang, Jianhua;Zhang, Yuying;Yang, Xu;Dong, Jun;Liu, Wenxia
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.433-440
    • /
    • 2014
  • In this study, a method for the low-carbon active distribution system (ADS) planning is proposed. It takes into account the impacts of both network capacity and demand correlation to the renewable energy accommodation, and incorporates demand response (DR) as an available resource in the ADS planning. The problem is formulated as a mixed integer nonlinear programming model, whereby the optimal allocation of renewable energy sources and the design of DR contract (i.e. payment incentives and default penalties) are determined simultaneously, in order to achieve the minimization of total cost and $CO_2$ emissions subjected to the system constraints. The uncertainties that involved are also considered by using the scenario synthesis method with the improved Taguchi's orthogonal array testing for reducing information redundancy. A novel cuckoo search (CS) is applied for the planning optimization. The case study results confirm the effectiveness and superiority of the proposed method.