• Title/Summary/Keyword: Low Power Laser

Search Result 367, Processing Time 0.029 seconds

Effects of surface hardening by using $CO_2$ laser defocussed beam on the fatigue resistance of ductile irons ($CO_2$ 레이저 분산빔에 의한 표면경화가 구상흑연주철의 피로특성에 미치는 영향)

  • 박근웅;한유희;이상윤
    • Laser Solutions
    • /
    • v.2 no.2
    • /
    • pp.42-51
    • /
    • 1999
  • This study has been performed to investigate into some effects of the output power and traverse speed of laser beam on the microstructures, hardness and fatigue resistance of the ductile iron surface-hardened by $CO_2$ laser defocussed beam. Optical micrographs have shown that with increasing the output power and decreasing the traverse speed, the martensite was coarsened and some retained austenite were appeared in ductile iron. The microstructures of hardening zone were composed of bull's eye and some nodular graphite dissolved structures by the effect of self quenching. Fatigue fracture characteristics of ductile iron have appeared in the high stress and low stress ranges. The fracture initiated at nodular graphites in the surface hardened layer due to the stress concentration caused by a notch effect. The interior graphite nodules were broken away or popped out during crack propagation. Fatigue test has shown that values of fatigue strength considerably increased with increasing output power at a given traverse speed.

  • PDF

Study on High Speed Laser Cutting of Rigid Flexible Printed Circuit Board by using UV Laser with Nano-second Pulse Width (자외선 나노초 펄스 레이저를 이용한 경연성(Rigid Flexible) 인쇄전자회로기판(Printed Circuit Board) 고속 절단에 관한 연구)

  • Bae, Han-Sung;Park, Hee-Chun;Ryu, Kwang-Hyun;Nam, Gi-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.20-24
    • /
    • 2010
  • High speed cutting processes of rigid flexible printed circuit board by making use of high power UV laser with nano-second pulse width have been proposed and investigated experimentally. Also robust laser cutting system has been designed and developed in order to obtain a good cutting quality of rigid and flexible PCB with multi-layers (2-6 layers). Power controller module developed for ourselves is adapted to control the laser output power in the range less than 1%. The systems show the good performance of cutting speed, cutting width and cutting accuracy, respectively. Especially we have confirmed that the short circuit problem due to the carbonized contamination occurred in cross section of multi-layers by thermal effect of high power laser has been improved largely by using multi-pass cutting process with low power and high speed.

Study on the Fatigue Resistance of Gray Cast Iron in CO2 Laser Surface Hardening (CO2레이저 표면경화(表面硬化) 처리된 회주철(灰鑄鐵)의 피로특성(疲勞特性)에 관한 연구(硏究))

  • Park, K.W.;Han, Y.H.;Lee, S.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.8 no.3
    • /
    • pp.169-181
    • /
    • 1995
  • This study has been performed to investigate some effects of the power density and traverse speed of laser beam on the optical microstructure, hardness and fatigue resistance of gray cast iron treated by laser surface hardening technique. Optical micrograph has shown that the dissolution of graphite flakes and the coarsening of lath martensite tend to increase with a small amount of retained austenite as the power density increases under the condition of a given traverse speed. Hardness measurements have revealed that as the power density increases, hardness values of outermost surface layer increases from Hv=620 to Hv=647 in case of traverse speed of 2.0m/min at gray cast iron. Fatigue test has exhibited that the fatigue strength of laser surface hardened specimen is superier compared to that of untreated specimen, showing that values for the fatigue strength at $N_f=10^7$ of gray cast iron laser-surface-hardened at a low power density of $4076w/cm^2$ and a high power density of $8153w/cm^2$ under the condition of a given traverse speed of 2.0m/min are $15kg_f/mm^2$ and $20kg_f/mm^2$, respectively, whereas the fatigue strength of untreated specimen is $11kg_f/mm^2$. Under high stress-low cycle condition a noraml brittleness fracture appears, whereas a ductile fracture with beach mark is observed in the specimen tested under low stress-high cycle condition.

  • PDF

Low-threshold Photonic Crystal Lasers from InGaAsP Free-standing Slab Structures

  • Ryu, Han-Youl;Kim, Se-Heom;Kwon, Soon-Hong;Park, Hong-Gyu;Lee, Yong-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.59-71
    • /
    • 2002
  • Photonic band gap structures have a high potential for nearly zero-threshold lasers. This paper describes new-types of low-threshold photonic crystal lasers fabricated in InGaAsP slab waveguides free-standing in air. Two-types of photonic crystal lasers are studied. One is a single-cell nano-cavity laser formed in a square array of air holes. This photonic band gap laser operates in the smallest possible whispering gallery mode with a theoretical Q >30000 and exhibits low threshold pump power of 0.8 mW at room temperature. The nther laser does not have any cavity structure and the lasing operation originates from the enhanced optical density of states near photonic band edges. A very low threshold of 35 $\mu$W (incident pump power) is achieved from this laser at 80 K, one of the lowest values ever reported. This low threshold is benefited from low optical losses as well as enhanced material gain at low temperature.

Development of Multi-wavelength Laser Medical Therapy Apparatus (다파장 레이저치료기의 개발)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.736-741
    • /
    • 2007
  • Low level laser therapy has various therapy effects, This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm, 785nm and 850nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. In result, the $1{\sim}10\;Hz$ irradiation frequency could be controlled stably.

Effects of the Low Power He-Ne IR Laser Treatment on the Liver Damage Induced with $CCI_4$ in Rats

  • Rho Min-Hee;Kim Jai-Young
    • Biomedical Science Letters
    • /
    • v.10 no.3
    • /
    • pp.231-235
    • /
    • 2004
  • This study was investigated the effects of the lower power He-Ne IR laser treatment on the changes of blood biochemical components in the rat liver damaged by the carbon tetrachloride (CCl₄). The twenty one Sprague-Dawley adult male rats weights (260±18.6 g) were designed to the three groups: one control group and two experimental groups, the experimental groups were divided into the CCl₄-treated groups and the laser therapy group (CCl₄+ Laser). The experimental groups were injected twice with CCl₄(1.0 ml/kg body weight) intraperitoneal for two days. Each group was sacrificed after two weeks irradiated with the lower power He-Ne IR laser for ten minutes per every day. The activity of alanine aminotransferase (ALT), lactic dehydrogenase (LDH), alkaline phosphatase (ALP) and the concentration of serum glucose treated with He-Ne IR laser groups was significantly decreased to the conrtol (treated with carbon CCl₄) group. The activity of aspartate aminotransferase (AST) was decreased in the laser group but not significantly, the concentration of the serum cholesterol in the laser group was significantly increased comparing with the control and case control groups. In conclusion, the effect of the lower power He-Ne IR laser treatment is believed to be a possible protective effects for CCl₄ induced acute hepatotoxicity in rats.

  • PDF

Microstructure and electrical properties of high power laser thermal annealing on inkjet printed Ag films

  • Yoon, Yo-Han;Yi, Seol-Min;Yim, Jung-Ryoul;Lee, Ji-Hoon;Joo, Young-Chang
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.36.2-36.2
    • /
    • 2009
  • In this work, the high power CW Nd:YAG laser has been used for thermal treatment of inkjet printed Ag films-involving eliminating organic additives (dispersant, binder, and organic solvent) of Ag ink and annealing Ag nanoparticles. By optimizing laser parameters, such as laser power and defocusing value, the laser energy can totally be converted to heat energy, which is used to thermal treatment of inkjet printed Ag films. This results in controlling the microstructures and the resistivity of films. We investigated the thermal diffusion mechanisms during laser annealing and the resulting microstructures. The impact of high power laser annealing on microstructures and electrical characteristic of inkjet printed Ag films is compared to those of the films annealed by a conventional furnace annealing. Focused ion beam (FIB) channeling image shows that the laser annealed Ag films have large columnar grains and dense structure (void free), while furnace annealed films have tiny grains and exhibit void formation. Due to these microstructural characteristics of laser annealed films, it has better electrical property (low resistivity) compared to furnace annealed samples.

  • PDF

Experiments on Welding of Ceramics by Use of High Power Laser (고출력 레이저를 이용한 세라믹 재료의 용접 실험)

  • 변철웅
    • Journal of Welding and Joining
    • /
    • v.12 no.2
    • /
    • pp.39-48
    • /
    • 1994
  • In comparison to the conventional brazing, laser welding of ceramics has advantages of direct bonding without filler material, which causes the thermal stress due to the differences of thermal expansion coefficients. In pulse-mode, laser welding of dispersion ceramic having high thermal resistance is possible at relatively low preheating temperature of $1300^{\circ}C$ In CW-mode, alumina can be welded at high preheating temperature $1500^{\circ}C$ under the condition of low feed rate of 500 mm/min, respectively. Further studies on developing mechanism of pores in the bead during laser welding of ceramics is required.

  • PDF

Chaotic State of a C.W.$CO_2$ laser Modulated by a Low Frequency Modulator (낮은 주파수로 변조된 C.W .$CO_2$ 레이저 빛의 혼란상태)

  • 김칠민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.73-75
    • /
    • 1989
  • Chaotic states of a low-frequency modulating C.W .Co2 laser beam is observed. The output behaviors appear quasi-periodicity and chaotic states when the laser beam is modulated from 100Hz to 1000Hz by using an intracavity chopper. And the output characteristics of the laser beam show a route to chaos as increasing input power when the modulation speed is 500Hz.

  • PDF

The Effects of Low Power Laser Treatment on Tissue Inflammatory Reactions in the Linear Incision Wound on Rat Skin (흰 쥐의 선상 절개 창상모델에서 저출력 레이저 자극이 조직 염증반응에 미치는 영향)

  • Lim, In-Hyuk;Lee, Jeong-Weon;Kim, Hyun-Sook
    • Physical Therapy Korea
    • /
    • v.10 no.2
    • /
    • pp.61-70
    • /
    • 2003
  • The purposes of this study was to evaluate the effect of low power GaAsAl laser on tissue contraction in a linear incision wound on rat skin. The linear incision wound was made on the midline of the backside in the experimental animals. Low power laser applications with different intensities such as 3, 6, or 10 mW were applied to the experimental animals twice a day for 10 days. On either the seventh or tenth postoperative day, the quantitative analysis of the inflammatory reaction surrounding the linear incision wounds on the rats were performed using enzymatical analysis of myeloperoxidase (MPO) activity. The number of neutrophil was $.07-1.0{\times}106/m{\ell}$ from a normal blood sample that was obtained from the normal experimental animals. Each concentration of neutrophil showed .04-.62 unit activity of MPO. Therefore, the 6 unit activity of MPO per neutrophil was $.57{\pm}.014{\times}10^{-6}$ unit. On the 7th and 10th post operative day, non treated tissues demonstrated increased MPO activity as compared to that of normal tissue. These data indicated that the inflammatory reaction of tissue was induced after wound induction and the MPO activity were increased in the inflammed tissues. While both 3 mW or 6 mW intensity of laser treatments did not affect the tissue MPO activity, 10 mW intensity of laser treatment significantly decreased the tissue MPO activity on the 7th and 10th post operative day. These data demonstrated that only 10 mW intensity of laser treatment successfully suppressed tissue inflammatory reaction after wound induction. In conclusion, these findings suggested that 10 mW of GaAIAs laser treatments effectively suppressed the inflammatory reaction of tissue that was induced during the wound healing process.

  • PDF