• Title/Summary/Keyword: Low Mode

Search Result 3,323, Processing Time 0.04 seconds

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

Design of A Low Power Memory Tag for Storing Emergency Manuals (긴급 매뉴얼 저장용 저전력 메모리 태그의 설계)

  • Kwak, Noh Sup;Eun, Seongbae;Son, Kyung A;Cha, Shin
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.2
    • /
    • pp.293-300
    • /
    • 2020
  • Since the communication networks like the Internet collapses at disaster and calamity sites, a maintenance system that can be operated offline is required for the maintenance of various facilities. In this paper, we propose a system that memory tags attached on the facilities may transmit the emergency manual to a smart-phone, and the smart phone displays it off-line. The main issue is to design low energy mode memory tags. This study presents two kinds of methods and analyzes each's energy consumption mode. The first one is to develop memory tags by using one chip, and the next one is to design memory tags by forming multi-modules. Both ways show proper application fields under the low energy mode. This research selects the off-line maintenance system by using one chip design, and proposes the direction of contents for enhancing the effectiveness of the system. And we expect that this memory tags will be valuable for disaster scenes as well as battle fields.

Analysis and Implementation of a New Single Switch, High Voltage Gain DC-DC Converter with a Wide CCM Operation Range and Reduced Components Voltage Stress

  • Honarjoo, Babak;Madani, Seyed M.;Niroomand, Mehdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.11-22
    • /
    • 2018
  • This paper presents a single switch, high step-up, non-isolated dc-dc converter suitable for renewable energy applications. The proposed converter is composed of a coupled inductor, a passive clamp circuit, a switched capacitor and voltage lift circuits. The passive clamp recovers the leakage inductance energy of the coupled inductor and limits the voltage spike on the switch. The configuration of the passive clamp and switched capacitor circuit increases the voltage gain. A wide continuous conduction mode (CCM) operation range, a low turn ratio for the coupled inductor, low voltage stress on the switch, switch turn on under almost zero current switching (ZCS), low voltage stress on the diodes, leakage inductance energy recovery, high efficiency and a high voltage gain without a large duty cycle are the benefits of this converter. The steady state operation of the converter in the continuous conduction mode (CCM) and discontinuous conduction mode (DCM) is discussed and analyzed. A 200W prototype converter with a 28V input and a 380V output voltage is implemented and tested to verify the theoretical analysis.

Development of the High Input Voltage Self-Power for LVDC

  • Kim, Kuk-Hyeon;Kim, Soo-Yeon;Choi, Eun-Kyung;HwangBo, Chan;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_1
    • /
    • pp.387-395
    • /
    • 2021
  • Distributed resources such as renewable energy sources and ESS are connected to the low voltage direct current(LVDC) distribution network through the power conversion system(PCS). Control power is required for the operation of the PCS. In general, controller power is supplied from AC power or DC power through switch mode power supply(SMPS). However, the conventional SMPS has a low input voltage, so development and research on high input voltage self-power suitable for LVDC is insufficient. In this paper, to develop Self-Power that can be used for LVDC, the characteristics of the conventional topology are analyzed, and a series-input single-output flyback converter using a flux-sharing transformer for high voltage is designed. The high input voltage Self-Power was designed in the DCM(discontinuous current mode) to reduce the switching loss and solve the problem of current dissipation. In addition, since it operates even at low input voltage, it can be applied to many applications as well as LVDC. The validity of the proposed high input voltage self-power is verified through experiments.

The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control (아날로그 회로로 구현가능한 평균전류제어 저손실 bypass 전류센싱방법)

  • Kim, Seok-Hee;Choi, Byung-Min;Park, Joung-Hu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.133-138
    • /
    • 2014
  • This paper proposes a low power-loss averaging current mode control using a resistor and bypass switch. Generally, current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. An analog-circuited bypass driver is implemented and used along with an average-circuit mode controller. The bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 50[W] prototype average current mode boost converter has been implemented for the experimental verification.

Precise Control for Servo Systems Using Sliding Mode Observer and Controller (슬라이딩 모드 관측기와 제어기를 이용한 서보시스템의 정밀제어)

  • Han, Seong-Ik;Gong, Jun-Hui;Sin, Dae-Wang;Kim, Jong-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.154-162
    • /
    • 2002
  • The effect of nonlinear friction in the low velocity is dominant in precise controlled mechanisms and it is difficult to model. This paper is concerned with the compensation for friction using the variable structure system approach as nonmodel based method. The problem of chattering in the sliding mode controller is suppressed by the implementation of the boundary layer concept. And the estimation for friction using sliding mode observer makes the upper bound of matched uncertainty reduced. Accordingly, the effect of chattering can be more suppressed. And the sliding surface is constructed by adding an integral component to the switching function that is made by using error dynamics. This sliding surface guarantees the good tracking performance. Experimental results for a XY table system show that the proposed method has a good performance especially in the low velocity.

Study on Multi-Mode Monopulse Signal Processing System Providing Optimal Time Delay under High Doppler Condition (고속 도플러 편이 환경에서 최적 시간지연을 갖는 다중모드 모노펄스 신호처리에 관한 연구)

  • Lee, Jaemoon;Lim, Jaesung;Ahn, Huisoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.582-589
    • /
    • 2016
  • Multi-mode monopulse system is widely used for satellite terminal like UAV because of high tracking accuracy and low size/weight profile. In order to calculate tracking error, Multi-mode monopulse system utilizes high-order mode signal, and it should have enough C/N(carrier to noise) level therefore tracking system needs narrow band filtering of received satellite beacon signal as much as possible. However, UAV suffers for beacon frequency drift derived from Doppler effect due to satellite figure 8 movement and UAV maneuvering. Therefore wideband signal processing needs to be considered in advance for exact doppler compensation and consequent time delay. In this paper, we propose the multi-stage Digital Signal processing system for beacon signal, which could minimize the signal delay under high Doppler and low C/N condition.

A New Criterion of Cell Discard in an ATM Switch with Input and Output Buffers (입출력버퍼형 ATM 교환기의 셀 폐기 방법에 대한 새로운 기준 제안 및 성능 분석)

  • Gwon, Se-Dong;Park, Hyeon-Min;Choe, Byeong-Seok;Park, Jae-Hyeon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.4
    • /
    • pp.1246-1264
    • /
    • 2000
  • An input-output buffering switch operates in either of tow different cell loss modes; Backpressure mode and Queueloss mode. In the previous studies, the Backpressrue mode is more effective at low traffic loads, and the Queueloss mode performs better at high traffic. We propose a new operation mode, called Hybrid mode, which adopts the advantages of he Backpressure and the Queueloss mode. Backpressure and Queueloss modes are distinguished from whether a cell loss occurs at the output buffer or not when output buffer overflows, irrespective of input buffer status. In order to simply combine Backpressure and Queueloss mode, the change of input traffic load must be measured. However, in the Hybrid mode, simply both of the input and output buffer overflow and checked out to determine the cell discard. The performance of the Hybrid mode is compared with those of the Backpressure and the Queueloss mode under random and bursty traffic. This paper show that the Hybrid mode always gives the best performance results for most ranges of load values.

  • PDF

Mppt control of PMSG wInd power system using adaptive sliding mode control (적응 슬라이딩 모드제어를 통한 PMSG 풍력발전시스템의 MPPT제어)

  • Jeong, Hyeong-Cheol;Chun, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1060-1061
    • /
    • 2015
  • This paper presents the control method of MPPT (Maximum Power Point Tracking) using back-to- back converter. The windturbine system use PMSG(ermanent Magnet Synchronous Generator) system considering low maintenance costs and driving performance at low wind. This paper use the adaptive sliding mode control to the torque control. Proposed method was analyzed mathematically.

  • PDF

Design of Transflective Low-twist VA mode for High Transmittance (높은 투과율을 갖는 반투과형 Low-Twist VA mode 설계)

  • 도희욱;백봉진;이서헌;윤태훈;김재창
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.118-119
    • /
    • 2003
  • 휴대용 통신기기의 발달로 인해 실내 및 실외 환경에서 높은 성능을 발휘하는 LCD 소자가 요구되고 있다. 후면광원을 사용하는 투과형 LCD는 실내 혹은 어두운 곳에서 높은 휘도와 명암대비비를 가지는 반면 실외나 밝은 곳에서는 높은 휘도 및 명암대비비를 보일 수 없다. 그에 반해 반사형 LCD는 주변광을 광원으로 사용하므로 실외 혹은 밝은 곳에서의 전기광학 특성이 양호한 장점이 있지만 실내 및 어두운 곳에서의 사용이 제한된다. (중략)

  • PDF