• 제목/요약/키워드: Low Mass Flow Rate

검색결과 253건 처리시간 0.025초

암모니아-물 흡수식 시스템에서 유하액막식 발생기의 해석 (Analysis of Falling-film Generator in Ammonia-water Absorption System)

  • 김병주;손병후;구기갑
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.422-430
    • /
    • 2001
  • In the present study, an evaporative generation process of ammonia-water solution film on the vertical plate was analysed. For the utilization of waste heat, hot water of low temperature was used as the heat source. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. Counter-current solution-vapor flow resulted in the refrigerant vapor of the higher ammonia concentration than that of co-current flow. Eve the rectification of refrigerant vapor was observed near the inlet of solution film in counter-current flow. For the optimum operation of generator using hot water, numerical experiments, based on the heat exchange and generation efficiencies. revealed the inter-relationships among the Reynolds number of the solution film and hot water, and the length of generator. Enhancement of heat and mass transport in the solution film was found to be very effective for the improvement of generation performance, especially at high solution flow rate.

  • PDF

용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰 (Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

액상으로 분사되는 기체의 불안정성 해석 (Instability analysis of gas injection into liquid)

  • 김형준;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.57-60
    • /
    • 2006
  • 액상의 환경으로 고속의 기체가 분사될 때 기체-액체 표면에서 일어나는 불안정성에 대해 점성전위 유동의 이론을 이용하여 분석하였다. 기체의 속도가 낮을 경우 액상으로 기포로 형성되지만 속도가 증가하면서 기체는 제트의 형태로 변하게 되는데, 천음속 구간에서 제트로 변하게 되는 것으로 알려져 있다. 본 연구에서는 주로 액체 제트를 해석하는데 사용된 점성전위유동이론을 기체 제트의 불안정성 해석에 응용하였다. 천음속 구간에서 기체 제트의 성장률이 변하는 것을 확인하였다. 초음속 구간으로 가면서 성장률이 감소하는 것을 확인하였다. 그리고 이를 레이놀즈수와 같은 무차원수에 대해 기체 제트의 성장률의 변화에 대해 알아보았다.

  • PDF

A Study on Coolant Mixing in Multirod Bundle Subchannels

  • Cha, Jong-Hee;Cho, Moon-Haeng
    • Nuclear Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.19-25
    • /
    • 1970
  • 이 연구는 다봉속내에서의 인접유로간의 냉각재 혼합류를 실험적으로 다룬 것이다. 실험은 19봉속내의 사각형 유로와 삼각형 유로간의 혼합류를 단상 유동과 공기-물 이상 유동에 물질 전달량을 측정하여 얻고 있다. 실험결과는 단상 유동에서 낮은 혼합률을, 공기-물 이상 유동에서 큰 혼합률을 얻고 있으며 공기-물 유동에서의 혼합률은 공기 체적률의 증가에 따라 감소되고 있음을 나타내고 있다. 공기-물 이상 유동에서의 높은 혼합률은 공기류에 의한 충분한 교란효과 때문인 것 같다.

  • PDF

콘 칼로리미터의 배기 덕트 내부 유동 특성 기초 실험 (Fundamental Experiment on the Flow Characteristics inside the Exhaust Duct of Cone Calorimeter)

  • 신연제;유우준
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.35-40
    • /
    • 2019
  • 본 연구에서는 콘 칼로리미터의 발열량 산출 값에 대한 신뢰성 평가를 위한 기초 연구로 산소소모지수법의 주요 인자인 질량유량에 관한 측정 불확도 관계식을 분석하였다. 본 연구에서 사용한 콘 칼로리미터의 덕트는 길이가 5 m이고 직경이 0.2 m로 내부가 완전히 빈 공간인 경우와 기공의 직경이 3 mm인 격자망 그리고 기공의 직경 10 mm와 기공률 0.76인 허니컴 형상의 덕트를 각각 제작하였다. 덕트 내부로 유입되는 질량유량을 산출하기 위해서 양방향 차압계와 온도센서를 유동의 수직방향으로 균일한 위치에 4개씩 설치하였으며, 레이놀즈 수 증가에 따른 속도구배와 유동의 섭동을 측정하였다. 그 결과 흡입용량이 증가할수록 난류강도에 비례하여 세 가지 형상 모두 속도구배가 증가하였으며, 95% 신뢰수준에서 질량유량에 대한 확장 불확도의 편차는 완전히 빈 공간, 격자망(dp = 3 mm) 그리고 허니컴(dp = 10 mm, 𝜖 = 0.76) 순으로 낮게 나타났다. 주목할 만한 점으로는 송풍기의 흡입용량이 가장 높은 조건일 때 격자망(dp = 3 mm)이 허니컴(dp = 10 mm, 𝜖 = 0.76) 형상에 비해서 흡입용량의 저항성은 높은데 비해서 질량유량의 확장불확도는 오히려 증가하였으며, 본 연구의 결과는 콘 칼로리미터의 덕트 내부 유동 안정성 향상을 위한 설계 자료의 활용이 가능할 것으로 판단된다.

Design and Performance Analysis of Conical Solar Concentrator

  • Na, Mun Soo;Hwang, Joon Yeal;Hwang, Seong Geun;Lee, Joo Hee;Lee, Gwi Hyun
    • Journal of Biosystems Engineering
    • /
    • 제43권1호
    • /
    • pp.21-29
    • /
    • 2018
  • Purpose: The objective of this study is to evaluate the performance of the conical solar concentrator (CSC) system, whose design is focused on increasing its collecting efficiency by determining the optimal conical angle through a theoretical study. Methods: The design and thermal performance analysis of a solar concentrator system based on a $45^{\circ}$ conical concentrator were conducted utilizing different mass flow rates. For an accurate comparison of these flow rates, three equivalent systems were tested under the same operating conditions, such as the incident direct solar radiation, and ambient and inlet temperatures. In order to minimize heat loss, the optimal double tube absorber length was selected by considering the law of reflection. A series of experiments utilizing water as operating fluid and two-axis solar tracking systems were performed under a clear or cloudless sky. Results: The analysis results of the CSC system according to varying mass flow rates showed that the collecting efficiency tended to increase as the flow rate increased. However, the collecting efficiency decreased as the flow rate increased beyond the optimal value. In order to optimize the collecting efficiency, the conical angle, which is a design factor of CSC, was selected to be $45^{\circ}$ because its use theoretically yielded a low heat loss. The collecting efficiency was observed to be lowest at 0.03 kg/s and highest at 0.06 kg/s. All efficiencies were reduced over time because of variations in ambient and inlet temperatures throughout the day. The maximum efficiency calculated at an optimum flow rate of 0.06 kg/s was 85%, which is higher than those of the other flow rates. Conclusions: It was reasonable to set the conical angle and mass flow rate to achieve the maximum CSC system efficiency in this study at $45^{\circ}$ and 0.06 kg/s, respectively.

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2011
  • 2중관형과 판형 열교환기에 에틸렌 클리콜-물 수용액으로 만들어진 아이스슬러리를 적용하는 경우의 유동 및 열적 특성을 규명하기 위하여 실험을 수행하였다. 아이스슬러리의 질량유속과 얼음 분율은 각각 800에서 3500 kg/$m^2s$과 0에서 25%이었다. 실험을 통해, 압력강하와 열전달율은 질량유속과 얼음 분율에 따라 증가하였다. 그러나 얼음 분율의 효과는 높은 질량유속 영역에서는 크지 않은 것으로 나타났다. 낮은 질량유속에서는 압력강하와 열전달율의 급속한 증가가 질량 유속에 관계되는 것으로 나타났다.

개도율에 따른 가스파이프라인용 볼 밸브 후류유동의 수치평가 (Numerical Evaluation of Flow Nature at the Downstream of a Ball Valve Used for Gas Pipelines with Valve Opening Rates)

  • 김철규;이상문;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제29권4호
    • /
    • pp.370-377
    • /
    • 2018
  • Ball valve has been widely used in the field of high-pressure gas pipeline as an important component because of its low flow resistance and good leakage performance. The present paper focuses on the flow nature at the downstream of the ball valve used for gas pipelines according to valve opening rates. Steady 3-D RANS equations, SC/Tetra, have been introduced to analyze the flow characteristics inside the ball valve. Numerical boundary conditions at the inlet and outlet of the valve system are imposed by mass flow-rate and pressure, respectively. Velocity distributions obtained by numerical simulation are compared with respect to the valve opening rates of 30, 50, and 70%. Cavity distributions, asymmetry flow velocity and the flow stabilization point at each opening rate are also compared. When the valve opening rates are 30 and 50%, the flow stabilization requires the sufficient length of 10D or more due to the influence of the recirculation flow at the downstream of the valve.

피스톤 냉각용 Oil jet 유동해석 (NUMERICAL ANALYSIS ON INTERNAL FLOW OF OIL JET COOLING THE PISTON)

  • 권지혁;정호윤;이종훈;최윤환;이연원
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.219-222
    • /
    • 2005
  • Recently, the interest of the engine capacity and environment of the atmosphere is increasing, so the researches for the engine capacity have been conducted for a long time. But the internal environment of an automotive engine is very severe. A piston is exposed to combustion gas of over $2000^{\circ}C$ and strong friction is occurred by high speed motion in the cylinder. The fraction between piston and wall of the cylinder causes the increase of temperature in the engine. The temperature of the engine has an effect on the engine capacity. If the temperature is high, the capacity of the engine is low. So we have to maintain the optimum temperature. To maintain the optimum temperature, the enough flow rate of the engine oil is needed. The oil jet is used to control the flow rate of the engine oil and supply the engine oil to the piston and cylinder. The purpose of this study is to check the mass flow rate of the engine oil and the characteristics of internal flow of the oil jet. Flow pattern of the engine oil is very important because it concludes the loss in the oil jet. This study is the previous research about the oil jet and we will consider the movement of the ball check valve to get more accuracy result.

  • PDF

회전속도가 상반각 정익을 적용한 천음속 축류 압축기 성능에 미치는 영향 (Effects of Rotational Speed on the Performance in a Transonic Axial Compressor with a Dihedral Stator)

  • 황동하;최민석;백제현
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.27-36
    • /
    • 2014
  • This paper presents a numerical investigation of the effect of the rotation speed on the performance in a transonic axial compressor with the dihedral stator. Four stator geometries with different stacking line variables were tested in the flow simulations over the whole operating range. It was found that a large shroud loss at the rotor outlet and the subsequent shroud corner separation in the stator passage occurred at low mass flow rate with the 100 % design speed. The hub dihedral stator could suppress the shroud loss region and consequently improve the stall margin. In case of the 70 % design speed condition as the mass flow rate decreased, it was seen that the high loss region was placed at the midspan of the rotor passage. The dihedral stator slightly affected the local diffusion factor, but the performance of the compressor was not changed.