• Title/Summary/Keyword: Low Level Control

Search Result 2,814, Processing Time 0.038 seconds

Power Factor Improvement of Single-Phase Three-level Boost Converter (단상 Three-level boost converter의 역률개선)

  • 서영조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.384-387
    • /
    • 2000
  • In this paper Power factor correction circuit of single-phase three-level boost converter is proposed. The advantage of the proposed control scheme for three-level boost converter are low blocking voltage of each power device low THD(Total Harmonic Distortion) and high power factor. The control scheme is based on the current comparator capacitor compensator and region detector, In simulations the proposed system is validated.

  • PDF

A study on the digitalize and application of Steam Generator level control system for nuclear power plant (원전 증기발생기 수위제어 디지탈화 및 적응에 관한 연구)

  • Moon, Byung-Heuee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.265-267
    • /
    • 1993
  • A control for Steam Generator (S/C) level is very difficult by automatic control mode but also manual control node during plant start up and/or low power level operation with the analog control system because of a non-nominal process responce. The goal of this study is to improve and computerize and applicate for KO-RI #1 Steam Generator level control system.

  • PDF

Technique to Solve Problems Due to Load Increment in Maximum Efficiency Control of Stator Flux-Oriented Induction Motor Drive (유도전동기 고정자자속 기준제어의 최대효율제어에서 부하증가로 인한 문제 해결방법)

  • Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.69-74
    • /
    • 2007
  • Flux level is low in the maximum efficiency control of a stator flux-oriented control of induction motor under the light load. In this cast if the loaf torque is suddenly increased, torque component current is limited to the low level by torque-limit condition because of the low flux level. In this paper, a technique to solve the problem is proposed.

Cholesterol Lowering Effect of Enzymatic Hydrolysates of Squid in Rats

  • Park, Ju-Hyun;Lee, Jung-Eun;Kim, Sang-Moo;Kwak, Hae-Soo
    • Food Science and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1541-1544
    • /
    • 2009
  • This study evaluated effects of enzymatic hydrolysates of squid on cholesterol lowering in rats. Thirty male rats were blocked into 3 groups [high cholesterol diet (control), 5% normal squid, and 5% enzymatic hydrolysates of squid] and were raised for 10 weeks. Triglyceride level in enzymatic hydrolysates of squid-fed rats was lower than that in the control. Serum low density lipoprotein-cholesterol level followed in the order of control>normal squid>enzymatic hydrolysates. Serum high density lipoprotein-cholesterol level in enzymatic hydrolysates of squid-fed rats was higher than that in control rats. Liver cholesterol level in enzymatic hydrolysates of squid-fed rats was lower than that in control rats.

EFFECTS OF DIETARY TRYPTOPHAN LEVEL AND FOOD INTAKE ON ENERGY UTILIZATION BY MALE GROWING CHICKS

  • Sugahara, K.;Kubo, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.4
    • /
    • pp.647-651
    • /
    • 1992
  • Two experiments involving comparative slaughter procedures were conducted to see if the decrease in total energy retention (ER) resulted from the decreased food intake in growing chicks fed on a diet containing tryptophan less than the requirement. Ad libitum-feeding a diet containing 50% of tryptophan of a control diet (1.5 g/kg) decreased body weight gain, apparent metabolizable energy intake (AMEI), ER and ER : AMEI ratio. When both the control diet and the 0.75 g/kg tryptophan diet were tube-fed at the two levels of food intake, body weight gain was significantly lower in chicks on the low tryptophan diet than in the control chicks at each level of intake. AME : gross-energy ratio decreased only when the low tryptophan diet was tube-fed at the higher level of intake. Energy retained as protein was significantly decreased by the low tryptophan level and reduction of food intake. Energy retained as fat was affected by food intake. ER and ER : AMEI ratio were unaffected by dietary tryptophan level and were proportional to AMEI. Heat increment of feeding was affected by neither tryptophan nor food intake. These results indicate that the decreased ER in chicks fed on the low tryptophan diet was due mainly to the decreased food intake and not to the decreased efficiency of ME utilization.

Water Level Control of Nuclear Plant Steam Generator (원자력 발전소의 증기발생기 수위조절)

  • 이윤준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.753-764
    • /
    • 1992
  • The steam generator water level is difficult to control at low power due to its reversed responses to the feedwater flow, which are well known as the shrink and swell phenomena. With regard to this problem a new control scheme has been studied by which the level transients could be kept within permissible ranges at low power. The relations between the various input conditions to steam generator and the level transients have been examined to be expressed in the form of process transfer functions. Analog filters have been incorporated to be expressed in the process with proper control constants. This control scheme allows the prediction of level variation together with the corresponding feedwater rate and results in mider transients with good stabilites.

Analysis and Improvement of Low-Frequency Control of Speed-Sensorless AC Drive Fed by Three-Level Inverter

  • Chang Jie (Jay)
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.358-365
    • /
    • 2005
  • In induction machine drive without a speed sensor, the estimation of the motor flux and speed often becomes deteriorated at low speeds with low back EMF. Our analysis shows that, in addition to the state resistance variation, the estimated value of field orientation angle is often corrupted by accumulative errors from the integration of voltage variables at motor terminals that have low signal/noise ratio at low frequencies. A repetitive loop path of integration in the feedback can amplify this type of error, thus speeding up the degradation process. The control system runs into information starvation due to the loss of correct field orientation. The machine's spiral vectors are controlled only in a reduced dimension in this situation. A novel control scheme is developed to improve the control performance of motor's current, torque and speed at low frequencies. The scheme gains a full-dimensional vector control and is less sensitive to the combined effect of the error sources at the low frequencies. Experimental tests demonstrate promising performances are achievable even below 0.5 Hz.

Force Control of a Arm of Walking Training Robot

  • Shin, Ho-Cheol;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.171.2-171
    • /
    • 2001
  • This paper presents a force control of a arm of walking training robot. The current gait training apparatus in hospital are ineffective for the difficulty in keeping constant unloading level and constraining patients to walk freely. The proposed walking training robot is designed to unload body weight effectively during walking. The walking training robot consists of unloading manipulator and mobile platform. The manipulator driven with a electro-mechanical linear mechanism unloads body weight in various level. The mobile platform is wheel type, which allows to patients unconstrained walking. Unloading system with electro-mechanical linear mechanism has been developed, which has advantages such as low noise level, light weight, low manufacturing cost and low power consumption. A system model for the manipulator ...

  • PDF

Therapeutic Effects of Low-Level Laser Combined with LED on Post-operative Hand

  • Jeong-Sun Lee;Hwa-Kyung Shin
    • The Journal of Korean Physical Therapy
    • /
    • v.36 no.1
    • /
    • pp.14-20
    • /
    • 2024
  • Purpose: This study was performed to identify and investigate the therapeutic effects of low-level laser (LLL) combined with a light-emitting diode (LED) on post-operative wound healing and functional recovery after hand orthopedic surgery. Methods: The study subjects were twenty patients who had passed the acute inflammatory phase after hand orthopedic surgery and were assigned equally to an experimental or a control group. Phototherapy was administered three times weekly for two weeks. Changes in wound length, edema, pain, and hand function were measured. Results: Significant differences in wound length, edema, pain, and hand function were observed between the experimental and control groups (p<0.05). However, no significant intergroup difference was observed (p>0.05). Nonetheless, a comparison of results showed changes in the experiment group over the two-week study period were significantly greater than in the control group (p<0.05). Conclusion: These findings show that combined LLL plus LED phototherapy positively influences post-operative hand rehabilitation.

A Consistent Quality Bit Rate Control for the Line-Based Compression

  • Ham, Jung-Sik;Kim, Ho-Young;Lee, Seong-Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.5
    • /
    • pp.310-318
    • /
    • 2016
  • Emerging technologies such as the Internet of Things (IoT) and the Advanced Driver Assistant System (ADAS) often have image transmission functions with tough constraints, like low power and/or low delay, which require that they adopt line-based, low memory compression methods instead of existing frame-based image compression standards. Bit rate control in the conventional frame-based compression systems requires a lot of hardware resources when the scope of handled data falls at the frame level. On the other hand, attempts to reduce the heavy hardware resource requirement by focusing on line-level processing yield uneven image quality through the frame. In this paper, we propose a bit rate control that maintains consistency in image quality through the frame and improves the legibility of text regions. To find the line characteristics, the proposed bit rate control tests each line for ease of compression and the existence of text. Experiments on the proposed bit rate control show peak signal-to-noise ratios (PSNRs) similar to those of conventional bit rate controls, but with the use of significantly fewer hardware resources.