• Title/Summary/Keyword: Low Dose Radiation

Search Result 937, Processing Time 0.025 seconds

A Study on Dosimetric Characterization of Direct Yellow 12 Dye at High Radiation γ-Dose

  • Batool, Javaria;Shahid, Shaukat Ali;Ramiza, Ramiza;Akhtar, Nasim;Naz, Afshan;Yaseen, Maria;Ullah, Inam;Nadeem, Muhammad;Shakir, Imran
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2265-2268
    • /
    • 2012
  • Aqueous solution of oxygenated Direct yellow 12 dye has been evaluated spectrophotometrically as a possible gamma rays dosimeter. The neutral (pH-7), alkaline (pH-12.5) and acidic (pH-5.5) aqueous solution of the dye were prepared and exposed to various gamma doses. Absorption spectra of unirradiated and irradiated solutions were recorded at 400 nm peak. The increase in absorbance with the increase in irradiation dose was observed from 1 to 6 kGy. The stability response of the dye solution for different environmental conditions such as temperature (low & high), light and darkness were investigated during post irradiation storage for ten days. The dye solution showed high stability in darkness for the studied period. The optical density of the dye solution was found to be decreased at high temperature storage.

In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors (I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구)

  • Im, Kwang Seok;Choi, Hak Gi;Lee, Gi Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2013
  • Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

  • PDF

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF

Enhanced Radiosensitivity of Tumor Cells Treated with Vanadate in Vitro (Vanadate 처리가 종양세포의 방사선 감수성에 미치는 영향)

  • Lee, Myung-Za;Lee, Won-Young
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.129-141
    • /
    • 1994
  • Intracellular ions which have a major role in cellular function have been reported to affect repair of radiation damage. Recently it has been reported that ouabain sensitizes A549 tumor cellls but not CCL-120 normal cells to radiation. Ouabain inhibits the $Na^+-K^+$-pump rapidly thus it increases intracellular Na concentration, Vanadate which is distributed extensively in almost all living organisms is known to be a $Na^+-K^+$-ATPase inhibitors, This study was performed to see any change in radiosensitivity of tumor cell by vanadate and any role of $Na^+-K^+$ATPase in radiosensitization. Experiments have been carried out by pretreatment with vanadate in human cell line(A549, JMG) and mouse cell line(L1210, spleen). For the cell survival MTT assay was performed for A549 and JMC cells and frypan blue dye exclusion test for L120, and spleen cells. Measurements of $Na^+-K^+$-ATPase activity in control, vanadate treated cell, radiation treated cell (9 Gy for A549 and JMG, 2 Gy for L1201, spleen), and combined $10^{-6}M$ vanadate and radiation treated cells were done. The results were summerized as fellows. 1. L1210 cell was most radiosensitive, and spleen cell and JMG cell were intermediate, and A549 cell was least radiosensitive. 2. Mininum or no cytotoxicity was seen with vanadate below concentration of $10^{-6}M$. 3. In A549 cells there was a little change in radiosensitivity with treatment of vanadate. However radiation sensitization was shown in low dose level of radiation i. e. 2- Gy. In JMG cells no change in radiosensitivity was noted. Both L1210 and spleen cell had radiosensitization but change was greater in tumor cell. 4. $Na^+-K^+$-ATPase activity was inhibited significantly in tumor cell by treatment of vanadate. 5. Radiaiton itself inhibited $Na^+-K^+$-ATPase activity of tumor cell with high $Na^+-K^+$-ATPase concention. Increase in radiosensitivity by vanadate was closely associated with orginal $Na^+-K^+$-ATPase contents. From the above results vanadate had little cytotoxicity and it sensitized tumor cells to radiation. Inhibitory effect of vanadate on $Na^+-K^+$-ATPase activity might be one of the contributing factors for radiosensitization to tumor cells which has greater enzyme activity than that of normal cell. It was suggested vanadate could be used as a potential radiosensitizer for tumor cells.

  • PDF

Identification of Differentially Expressed Radiation-induced Genes in Cervix Carcinoma Cells Using Suppression Subtractive Hybridization (자궁경부암세포에서 방사선조사시 차등 발현되는 유전자 동정)

  • Kim Jun-Sang;Lee Young-Sook;Lee Jeung Hoon;Lee Woong-Hee;Seo Eun Young;Cho Moon-June
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • Purpose : A number of genes and their products are Induced early or late following exposure of cells to ionizing radiation. These radiation-Induced genes have various effects on irradiated cells and tissues. Suppression subtractive hybridization (SSH) based on PCR was used to Identify the differentially expressed genes by radiation in cervix carcinoma cells. Materials and Methods : Total RNA and poly $(A)^+$ mRNA were Isolated from Irradiated and non-irradiated HeLa cells. Forward- and reverse-subtracted cDNA libraries were constructed using SSH. Eighty-eight clones of each were used to randomly select differentially expressed genes using reverse Northern blotting (dot blot analysis). Northern blotting was used to verify the screened genes. Results : Of the 17t clones, 10 genes in the forward-subtracted library and 9 genes In the reverse-subtracted library were identified as differentially expressed radiation-induced genes by PCR-select differential screening. Three clones from the forward-subtracted library were confirmed by Northern blotting, and showed increased expression in a dose-dependent manner, including a telomerase catalytic subunit and sodium channel-like protein gene, and an ESTs (expressed sequence tags) gene. Conclusion : We Identified differentially expressed radiation-induced genes with low-abundance genes with SSH, but further characterization of theses genes are necessary to clarify the biological functions of them.

Studies on the Preservation of Pork Sausage by Gamma Radiation -Part 1. On the Enhancement of the Preservative Effect of Antiseptics by Gamma Radiation- (감마선 조사에 의한 Pork Sausage의 저장에 관한 연구 -제 1 보 방부제와 방사선과의 상승효과에 대하여-)

  • Kim, Yun-Jin;Park, Yong-Kun;Suh, Don-Yung
    • Korean Journal of Food Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.100-105
    • /
    • 1972
  • This experiment was conducted to investigate the combined effects of radiation and antiseptics on the keeping qualities of pork sausage, which was treated with potassium sorbate and AF-2(2-(-2-furyl)-3-(5-nitro-2-furyl)-acrylamide), and then followed by gamma radiation of 0.25, 0.5, and 0.75 Mrad. Amounts of treated antiseptics were a quarter, half, and full levels of their maximum permissible concentration. Irradiated and unirradiated sausages were stored for 50 days at $5^{\circ}C\;and\;25^{\circ}C$, and their changes in rancidity, volatile basic nitrogen, bacterial counts, pH, and sensory analysis were examined during the storage period. The results obtained are as follows: 1) Preservative effects of antiseptics were manifested at cold storage; antiseptics treatment of a quarter-level and unirradiation following low-temperature storage showed the same good keeping qualities as the combined treatment of full-level antiseptics and radiation of 0.25 Mrad following high-temperature storage. 2) There did not appear to recognize irradiation-odor, while color and odor were deteriorated intensively by storage temperature. Sausage irradiated with 0.75 Mrad has shown slightly noticeable off-odor at the end of storage at $25^{\circ}C$. 3) The most suitable radiation dose was considered to be 0.5 Mrad, which could extend the storage life about $2{\sim}3$ times longer than untreated.

  • PDF

Development of the Safety Assessment Code (CALM) for the Disposal of Low-and Intermediate-Level Radioactive Waste (중ㆍ저준위 방사성폐기물 처분안정성 평가코드(CALM) 개발)

  • Han, Kyong-Won;Cho, Won-Jin;Lee, Han-Soo;Lee, Youn-Myoung;Park, Hee-Sung;Suh, Kyung-Suk;Park, Heu-Joo-;Park, Hun-Hwee
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.36-44
    • /
    • 1990
  • A safety assessment computer code CALM (Computer program of Assessment for LILW Management) is developed for the theoretical prediction of long-term safety of low-and intermediate-level radioactive waste disposal. CALM is composed of three submodels, which are the resaturation model, the geosphere migration model, and the radiation dose model. For the verification of its usefulness, the safety assessment of an assumed waste repository is performed. The results show that the computer code, CALM developed through this study can be a useful tool for the safety assessment of low- and intermediate-level radioactive waste repository.

  • PDF

Detection Characteristics of Gamma-Irradiated Korean Medicinal Herbs by Using PSL, TL, and ESR (PSL, TL 및 ESR 분석에 의한 감마선 조사 한약재의 검지 특성)

  • Yang, Hee-Sun;Park, Yong-Dae;Jin, Chang-Hyun;Choi, Dae-Seong;Chung, Hyung-Wook;Byun, Myung-Woo;Jeong, Il-Yun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1529-1533
    • /
    • 2008
  • The detection characteristics of gamma-irradiated ($0{\sim}10.0\;kGy$) medicinal herbs (Platycodon grandiflorum, Acanthopanax chiisanensis) were investigated by photostimulated luminescence (PSL), thermoluminescence (TL), and electron spin resonance (ESR). The results of the PSL, a first screening method in comparison with the TL, showed photon counts greater than 5,000 counts/60 s (positive) in the irradiated samples, while the non-irradiated samples yielded photon counts less than 700 counts/60 s (negative). The TL was also applied for the detection method of irradiated medicinal herbs and showed that the non-irradiated sample revealed a glow curve with a low intensity, while the irradiated samples showed a higher intensity. These results were normalized by re-irradiating the mineral grains with a irradiation dose of 1.0 kGy, and a second glow curve was recorded. The ratio of the intensity of the first glow curve ($TL_1$) to that after the normalization dose ($TL_2$) was determined and compared with the recommended threshold values. TL ratio ($TL_1/TL_2$) was below 0.007 for the non-irradiated sample and higher than 0.1 for all irradiated samples (above 1.0 kGy). ESR spectroscopy revealed specific signals (6.065 mT) derived from free radicals in cellulose containing irradiated medicinal herbs. The P. grandiflorum showed clearer signals than A. chiisanensis. From the results of our studies, the PSL, TL, and ESR determinations were found to be suitable for the detection of irradiated medicinal herbs such as P. grandiflorum and A. chiisanensis.

Clinical Experience of LINAC-based Stereotactic Radiosurgery for Angiographically Occult Vascular Malformations (혈관조영상 잠재혈관기형에 대한 선형가속기형 정위방사선수술의 임상경험)

  • Kim Dae Yong;Ahn Yong Chan;Lee Jung Il;Nam Do-Hyun;Lim Do Hoon;Lee Jeong Eun;Yeo Inhwan;Huh Seung Jae;Noh Young Joo;Shin Seong Soo;Hong Seung-Chyul;Kim Jong Hyun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • Purpose : To establish the role of stereotactic radiosurgery (SRS) for the treatment of patients with angiographically occult vascular malformation (AOVM). Materials and Methods : Eleven patients (12 lesions) with AOVM were treated with linear accelerator-based SRS between February 1995 and December 1999. A magnetic resonance imaging of each patients showed well-circumscribed vascular lesion with reticulated core of heterogeneous signal intensity and peripheral rim of low signal intensity. SRS were peformed with the median peripheral dose of 16 Gy (range 13~25). A single isocenter was used with median collimator size of 14 mm (range 8~20) diameter. Results : With a median follow-up period of 42 months (range 12~56), rebleeding occurred in 3 AOVMS at 5, 6 and 12 months after SRS but no further bleeding did. Two patients experienced radiation-induced necrosis associated with permanent neurologic deficit and one patient showed transient edema of increased 72 signal intensity. Conclusion : SRS may be effective for the prevention of rebleeding in AOVM located in surgically inaccessible region of the brain. Careful consideration should be needed in the decision of case selection and dose prescription because the incidence of radiation-induced complications is too high to be accepted.

  • PDF

Analysis of Low MU Characteristics of Siemens Primus Linear Accelerator using Diode Arrays for IMRT QA (다이오드 어레이를 이용한 Siemens사의 Primus 선형가속기의 저 MU 특성 분석)

  • Kim, Ju-Ree;Lee, Re-Na;Lee, Kyung-Ja
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.164-171
    • /
    • 2008
  • One of the most important task in commissioning intensity modulated radiotherapy (IMRT) into a clinic is the characterization of dosimetry performance under small monitor unit delivery conditions. In this study, method of evaluating dose monitor linearity, beam flatness and symmetry, and MLC positioning accuracy using a diode array is investigated. Siemens Primus linear accelerator (LA) with 6 and 10 MV x-rays was used to deliver radiation and the characteristics were measured using a multi array diodes. Monitor unit stabilities were measured for both x-ray energies. The dose linearity errors for the 6 MV x-ray were 2.1, 3.4, 6.9, 8.6, and 15.4 % when 20 MU, 10 MU, 5 MU, 4 MU, and 2 MU was delivered, respectively. Greater errors were observed for 10 MV x-rays with a maximum of 22% when 2 MU was delivered. These errors were corrected by adjusting D1_C0 values and reduced to less than 2% in all cases. The beam flatness and symmetry were appropriate without any correction. The picket fence test performed using diode array and film measurement showed similar results. The use of diode array is a convenient method in characterizing beam stability, symmetry and flatness, and positioning accuracy of MLC for IMRT commissioning. In addition, adjustment of D1-C0 value must be performed when a Siemens LA is used for IMRT because factory value usually gives unacceptable beam stability error when the MU/segment is smaller than 20.

  • PDF