Browse > Article
http://dx.doi.org/10.5012/bkcs.2012.33.7.2265

A Study on Dosimetric Characterization of Direct Yellow 12 Dye at High Radiation γ-Dose  

Batool, Javaria (Department of Physics, University of Agriculture Faisalabad)
Shahid, Shaukat Ali (Department of Physics, University of Agriculture Faisalabad)
Ramiza, Ramiza (Department of Physics, University of Agriculture Faisalabad)
Akhtar, Nasim (Nuclear institute for Agriculture and Biology (NIAB))
Naz, Afshan (Department of Physics, University of Agriculture Faisalabad)
Yaseen, Maria (Department of Physics, University of Agriculture Faisalabad)
Ullah, Inam (Department of Chemistry and Biochemistry, University of Agriculture Faisalabad)
Nadeem, Muhammad (Subsurface Technology, PETRONAS, Research Sdn.Bhd.)
Shakir, Imran (Interdisciplinary Research Center in Biomedical Materials, COMSATS Institute of Information Technology)
Publication Information
Abstract
Aqueous solution of oxygenated Direct yellow 12 dye has been evaluated spectrophotometrically as a possible gamma rays dosimeter. The neutral (pH-7), alkaline (pH-12.5) and acidic (pH-5.5) aqueous solution of the dye were prepared and exposed to various gamma doses. Absorption spectra of unirradiated and irradiated solutions were recorded at 400 nm peak. The increase in absorbance with the increase in irradiation dose was observed from 1 to 6 kGy. The stability response of the dye solution for different environmental conditions such as temperature (low & high), light and darkness were investigated during post irradiation storage for ten days. The dye solution showed high stability in darkness for the studied period. The optical density of the dye solution was found to be decreased at high temperature storage.
Keywords
Direct yellow 12; Spectrophotometry; Gamma ray dosimeter; Optical density;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
연도 인용수 순위
  • Reference
1 Kent, J. A. Handbook of Industrial Chemistry, 10th ed.; Plenum Publishers: New York, 2003; p 892.
2 Parwate, D. V.; Sarma, I. D.; Batra, R. J. Rad. Measur. 2007, 42, 1527.   DOI
3 Rauf, M. A.; Ashraf, S. S. J. of Hazard. Mat. 2008, 166, 6.
4 Khan, H. M.; Anwar, M.; Chaudhry, Z. S. Rad. Phys. Chem. 2002, 63, 713.   DOI
5 Bagyo, A. N. M.; Andayani, W.; Winarno, H.; Katrin, E.; Soebianto, Y. S. Int. J. Env. Consc. Design Manufac. 2004, 12, 45.
6 Kovacs, A.; Wajnarovits, L.; Kurucz, C.; Al-Sheikhly, M.; Mclaughlin, W. L. Rad. Phys. Chem. 1998, 52, 539.   DOI
7 McLaughlin, W. L.; Kosanic, M. Int. J. Appl. Rad. Isotopes. 1974, 25, 249.   DOI
8 McLaughlin, W. L.; Boyed, A. W.; Chadwick, K. H.; McDonald, J. C.; Miller, A. Dosimetry for Radiation Processing; Taylor and Francis: London, 1989; Vol. 3, pp 402-406.
9 Khan, H. M.; Tabassum, S.; Wahid, M. S. J. Rad. Anal. and Nucl. Chem. 2009, 3, 635.
10 Barakat, M. F., Banna, M. E. Int. J. Low Rad. 2007, 4, 286.   DOI
11 Kattan, M.; Daher, Y.; AlKassiri, H. Rad. Phys. Chem. 2007, 76, 1195.   DOI
12 Kattan, M.; Kassiri, H.; Daher, Y. Appl. Rad. Isotopes. 2011, 69, 377   DOI