• 제목/요약/키워드: Low Dose Exposure

검색결과 473건 처리시간 0.025초

배양 심근세포에서 저농도 삼산화비소에 의한 산화적 스트레스 발생 (Oxidative Stress by Arsenic Trioxide in Cultured Rat Cardiomyocytes, $H_9C_2$ Cells)

  • 박은정;박광식
    • Environmental Analysis Health and Toxicology
    • /
    • 제21권1호
    • /
    • pp.71-79
    • /
    • 2006
  • Epidemiologic studies have showed a close correlation between arsenic exposure and heart disease such as, cardiovascular problem, ischemic heart disease, infarction, atherosclerosis and hypertension in human. It may increase the mortality of high risk group with heart disease. Regarding the mechanism studies of heart failure, blood vessel, vascular smooth muscle cells and endothelial cells have long been focused as the primary targets in arsenic exposure but there are only a few studies on the cardiomyocytes. In this study, the generation of oxidative stress by low dose of arsenic trioxide was investigated in rat cardiomyocytes. By direct measurement of reactive oxygen species and fluorescent microscopic observation using fluorescent dye 2',7'-dichlorofluorescin diacetate, reactive oxygen species were found to be generated without cell death, where cells are treated with 0.1 ppm arsenic for 24 hours. With the induction of reactive oxygen species, GSH level was decreased by the same treatment. However, DNA damage did not seem to be serious by DAPI staining, while high dose of arsenic (2 ppm for 24 hrs) caused fragmentation of DNA. To identify the molecular biomarkers of low-dose arsenic exposure, gene expression was also investigated with whole genome microarray. As results, 9,022 genes were up-regulated including heme oxygenase-l and glutathione S-transrerase, which are well-known biomarkers of oxidative stress. 9,404 genes were down-regulated including endothelial type gp 91-phox gene by the treatment of 0.1 ppm arsenic for 24 hours. This means that biological responses of cardiomyocytes may be altered by ROS induced by low level arsenic without cell death, and this alteration may be detected clearly by molecular biomarkers such as heme oxygenase-1.

Novel Dosimeter for Low-Dose Radiation Using Escherichia coli PQ37

  • Park, Seo-Hyoung;Kim, Tae-Hwan;Cho, Chul-Koo;Lee, Yeon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권3호
    • /
    • pp.524-528
    • /
    • 2001
  • The measurement of radiation response using simple and informative techniques would be of great value in studying the genetic risk following occupational, therapeutic, or accidental exposure to radiation. When patients receive radiation therapy, many suffer from side effects. Since each patient receives a different dose due to different physical conditions, it is important to measure the exact dose of radiation received by each patient to lessen the side effects. Even though several biological dosimetric systems have already been developed, there is no ideal system that can satisfy all the criteria for an idean dosimetric system, especially for low-dose radiation as used in radiation therapy. In this study, an SOS Chromotest of E. coli PQ37 was evaluated as a novel dosimeter for low-dose gamma-rays. E. coli PQ37 was originally developed to screen chemical mutagens using the SOS Chromotest-a colorimtric assay, based on the induction of ${\beta}$-galactosidase ue to DNA damage. The survival fraction of E. coli PQ37 decreased dose-dependently with an increasing dose of cobalt-60 gamma-rays. Also, a good linear correlation was found between the biological damage revealed by the ${\beta}$-galactosidase expression and the doses of gamma-rays. The expression of ${\beta}$-galactosidase activity that responded to low-dose radiation under 1 Gy was $Y=0.404+(0.089{\pm}0.3)D+(-0.018{\pm}0.16)D^2$ (Y, absorbance at 420 nm; D, Dose of irradiation) as calculated using Graph Pad In Plot and Excel. When a rabbit was fed with capsules containing an agar block embdded with E. coli PQ37 showed a linear response to the radiation doses. Accordingly, the results confirm that E. coli PQ37 can be used as a sensitive biological dosimeter fro cobalt-60 gamma-rays. To the best of our knowledge, this is the first time that a bacterium has been used as a biological dosimeter, especially for low-dose radiation.

  • PDF

저선량율의 감마선 조사에 의한 자주 달개비의 체세포 돌연변이 출현에 관한 연구 (Mutation Frequency of Tradescantia (BNL Clone 4430) Stamen Hairs Exposed to Low Dose of Gamma Ray in the KAERI ${\gamma}$-Field)

  • Shin Han Kwon;Young Il Lee;Kyu Hoi Chung;Jeung Haing Oh
    • Nuclear Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.161-167
    • /
    • 1981
  • 자주달개비(Tradescantia) BNL clone 4430을 본 연구소 감마농장(${\gamma}$-field)에 거리별로 배치하고 ${\gamma}$-선을 3.6mR/day~182R/day의 선량율로 완조사시켜, 이 식물의 수술털에 나타나는 분홍색 체세포돌연변이를 대상으로 돌연변이의 출현율을 조사하는 한편 화기에 미치는 형태변화를 조사하였다. 분홍색 체세포돌연변이율은 22.2R/day의 선량율에서 수술털 1,000개당 85.81$\pm$6.45개로 가장 높았고, 이보다 높은 선량율에서는 오히려 변이율이 감소하여 포화선량효과를 초래하였다. 또한 3.6mR/day의 낮은 선량율체서도 이 체세포돌연변이율이 자연돌연변이율보다 증가하였음을 볼 수 있었으며 비교적 낮은 선량율 조사에서는 꽃, 수술, 수술털등의 형태적 변화가 없이 돌연 변이율만의 증가를 볼수가 있어 감마농장내에서 과수나 화목등 영년식물에 저선량의 완조사를 통해 체세포돌연변이의 유기가 가능할것으로 보이며, 한편 이 식물의 특성을 이용하여 저위 방사선에 의한 유전적변화를 탐지하는데에도 적절한 수단이 될 것 같다.

  • PDF

폴리에틸렌 미세플라스틱의 임신 마우스 위내투여에 따른 모체 및 신생자 독성평가 (Toxicities Demonstrated in Dams and Neonates following Intragastric Intubation of Polyethylene Microplastics to Pregnant Mice)

  • 송영민;김창열
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.446-453
    • /
    • 2021
  • Background: Plastic particles less than 5 mm in diameter (microplastics) are well-known for causing various toxicities such as lung inflammation, oxidative stress, genotoxicity, and reproductive toxicity. As microplastics become smaller, they can move across cell membranes, the placenta, and the blood-brain barrier. Objectives: We evaluated the toxicities of polyethylene microplastics (PE-PMs) in dams and neonates through intragastric intubation of pregnant ICR mice. Methods: Low concentrations (0.01 mg/mouse/day) and high concentrations (0.1 mg/mouse/day) of polyethylene microplastics were administered from the ninth day of pregnancy to postnatal day seven. The control group was administered with distilled water. On the day of sacrifice, the weight of dams and neonates and the organ weight of neonates was measured. Further, acetylcholinesterase levels and glutathione peroxidase levels were evaluated by using a blood sample obtained on the sacrifice day. Results: No significant difference in the number of neonates was found, but the body weight gain of dams was seen to be lower in the low-dose group. On the other hand, we observed a consecutively declining trend in the weight gain and organ weight of neonates among the high-, control, and low-dose groups. Meanwhile, the serum acetylcholinesterase and glutathione peroxidase level were higher in the low-dose group compared to the control group. Further, the dose-dependent accumulation of microplastics in the organs of neonates revealed the transport of plastic particles from dams to their offspring. Conclusions: Although the exact mechanism of toxicity caused by microplastics could not be confirmed, it was validated that exposure to microplastics during pregnancy and lactation causes its migration between generations and accumulation throughout the body. Hence, it is necessary to evaluate the systemic toxicity of microplastics and assessment of co-morbidities such as second-generation toxicity, neurotoxicity, and depression following long-term exposure.

PREVENTION OF CIGARETTE SMOKE INDUCED LUNG CANCER BY LOW LET IONIZING RADIATION

  • Sanders, Charles L.
    • Nuclear Engineering and Technology
    • /
    • 제40권7호
    • /
    • pp.539-550
    • /
    • 2008
  • Lung cancer is the most prevalent global cancer, ${\sim}90%$ of which is caused by cigarette smoking. The LNT hypothesis has been inappropriately applied to estimate lung cancer risk due to ionizing radiation. A threshold of ${\sim}1\;Gy$ for lung cancer has been observed in never smokers. Lung cancer risk among nuclear workers, radiologists and diagnostically exposed patients was typically reduced by ${\sim}40%$ following exposure to <100 mSv low LET radiation. The consistency and magnitude of reduced lung cancer in nuclear workers and occurrence of reduced lung cancer in exposed non-worker populations could not be explained by the HWE. Ecologic studies of indoor radon showed highly significant reductions in lung cancer risk. A similar reduction in lung cancer was seen in a recent well designed case-control study of indoor radon, indicating that exposure to radon at the EPA action level is associated with a decrease of ${\sim}60%$ in lung cancer. A cumulative whole-body dose of ${\sim}1\;Gy$ gamma rays is associated with a marked decrease in smoking-induced lung cancer in plutonium workers. Low dose, low LET radiation appears to increase apoptosis mediated removal of $\alpha$-particle and cigarette smoke transformed pulmonary cells before they can develop into lung cancer.

디지털 방사선 촬영장치의 흉부촬영 최적 조사조건에 관한 연구 (The Study for Optimal Exposure Condition of Chest Examination of Digital Radiography System)

  • 박지군;정봉재;박형후;노시철;강상식
    • 한국방사선학회논문지
    • /
    • 제10권2호
    • /
    • pp.109-115
    • /
    • 2016
  • 방사선학 영역에서의 디지털 영상 장치의 사용이 급격히 증가되고 있음에도 불구하고, 사용 장치에서의 최적 조사 조건 설정이 미흡한 실정이다. 본 연구에서는 디지털 방사선 장치의 촬영조건에 따른 피폭선량과 화질을 비교 평가하고자 하였다. 이에 CR, DR의 디지털 방사선 촬영장치를 이용하여 현재 사용하고 있는 촬영조건을 기준으로 각 5단계씩 조건을 변경시키면서 피폭선량을 측정하였으며, 획득한 영상은 의료영상전문가 20명에게 일본 결핵예방학회의 평가법을 준용하여 평가하였다. 그 결과, CR 시스템의 경우 기준 조건인 110 kVp, 3.2 mAs에서의 화질평가 86점 보다 120 kVp, 1.5~2.4 mAs에서 화질평가 91, 95.5점으로 보다 우수하게 나타났으며, 이 때 피폭선량 또한 기준 조건에서의 $105.11{\mu}Gy$ 보다 낮은 $61.3{\sim}98.4{\mu}Gy$로 평가되었다. DR 시스템 경우는 오히려 기준 조건인 125 kVp, 3.2 mAs에서의 화질평가 91점보다 관전압이 낮은 영역인 112 kVp, 2.4~3.2 mAs에서 97점, 98.6점 사이의 높은 화질평가 점수를 나타내었으며, 피폭선량 또한 기준 조건에서의 $93{\mu}Gy$ 보다 낮은 $61.5{\mu}Gy$, $77.2{\mu}Gy$로 평가되었다. 이러한 결과는 디지털 장치의 적절한 조사조건을 설정함으로써 동일한 화질의 영상에 대해 환자 피폭선량을 저감시킬 수 있음을 확인할 수 있었다.

Effect of exposure energy dose on lateral resolution and flexural strength of three-dimensionally printed dental zirconia

  • Kyle Radomski;Yun-Hee Lee;Sang J Lee;Hyung-In Yoon
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권5호
    • /
    • pp.248-258
    • /
    • 2023
  • PURPOSE. This study aims to evaluate the effects of exposure energy on the lateral resolution and mechanical strength of dental zirconia manufactured using digital light processing (DLP). MATERIALS AND METHODS. A zirconia suspension and a custom top-down DLP printer were used for in-office manufacturing. The viscosity of the suspension and uniformity of the exposed light intensity were controlled. Based on the exposure energy dose delivered to each layer, the specimens were classified into three groups: low-energy (LE), medium-energy (ME), and high-energy (HE). For each energy group, a simplified molar cube was used to measure the widths of the outline (Xo and Yo) and isthmus (Xi and Yi), and a bar-shaped specimen of the sintered body was tested. A Kruskal-Wallis test for the lateral resolution and one-way analysis of variance for the mechanical strength were performed (α = .05). RESULTS. The zirconia green bodies of the ME group showed better lateral resolution than those of the LE and HE groups (both P < .001). Regarding the flexural strength of the sintered bodies, the ME group had the highest mean value, whereas the LE group had the lowest mean value (both P < .05). The ME group exhibited fewer agglomerates than the LE group, with no distinctive interlayer pores or surface defects. CONCLUSION. Based on these findings, the lateral resolution of the green body and flexural strength of the sintered body of dental zirconia could be affected by the exposure energy dose during DLP. The exposure energy should be optimized when fabricating DLP-based dental zirconia.

우리나라 남동지방(南東地方)의 환경방사선(環境放射線) 선량율(線量率)의 결정(決定)(1980년도(年度)) (Determination of Environmental Radiation Dose Rate in the Southeastern Korea)

  • 노재식;이현덕
    • Journal of Radiation Protection and Research
    • /
    • 제5권1호
    • /
    • pp.1-6
    • /
    • 1980
  • A portable count-ratemeter and a thermoluminescent detector ($CaSO_4:Dy$) have been used to obtain total gamma dose rates at approximately 50 locations during the course of several survey trips in the southeastern Korea. The purposes of these measurement were to provide a future reference data and to establish the approximate range of population exposure to the natural environmental radiation. The natural levels encountered ranged from a low of 14.6 microroentgen per hour to a high of 18.9 microroentgen per hour with a mean of $16.3{\pm}1.0$ microroentgen per hour. Among these results are the relatively high natural dose rate levels in the Masan area and Yangsan-Tongdosa area with the relatively low natural dose rate levels in the Gyeongsan-Cheongdo area and the Samrangjin-Jinyeong-Gimhae area.

  • PDF

유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교 (Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry)

  • 박태석;한준희;조승연;이은임;조규원;권대철
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

수용성 6가크롬을 흡입 노출 시킨 랫드의 체액과 적혈구중 크롬간의 관련성 연구 (Relationship between Chromium Concentration in Male Rats Fluids and Erythrocytes after Inhalation Exposure of Soluble Hexavalent Chromium Compound)

  • 김광종;김현영;윤수종;이은일
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.26-33
    • /
    • 2001
  • The goal of this study was to evaluate the relationship between ambient hexavalent chromium concentration and the concentration of the chromium in whole blood, plasma, erythrocytes, and its urinary excretion of male rats after inhalation exposure of sodium chromate during 1, 2, and 3 weeks. 1. Differences of mean chromium concentration in urine, whole blood, erythrocytes, and plasma of male rats exposed to sodium chromate by exposure level were statistically significance, respectively. 2. At low and high exposure groups, differences of mean chromium concentration in urine, whole blood, erythrocytes, and plasma of male rats by duration of inhalation exposure were statistically significance, respectively. 3. Ratio of whole blood chromium to plasma chromium increased with the increased duration of inhalation exposure of sodium chromate. 4. Ambient hexavalent chromium was positively and strongly correlated with in erythrocyte chromium, and also erythrocyte chromium was strongly correlated with in whole blood chromium. In conclusion, this study showed that chromium in erythrocyte increased with the increased exposure level and exposure duration, therefore this study suggests that chromium in erythrocytes is a good biological exposure index of the internal dose from exposure to soluble hexavalent chromium compound.

  • PDF