• Title/Summary/Keyword: Low Dose Exposure

Search Result 473, Processing Time 0.028 seconds

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.

Nationwise Survey of the X-ray Beam Collimator Utilization in General Diagnostic Radiograph (진단방사선 일반촬영에서의 X-ray Beam Collimator 사용 전국 실태조사)

  • Kim, Jee Hye;Sung, Dong-Wook;Kim, Jeong Wook;Shin, Jin Ho;Lee, Soon Keun;Jung, Kyung Il;Uhm, Jong Kwan;Lee, Ki Nam;Seong, Ho Jin;Kim, Youn Hyun;Kim, Hyeog Ju
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.119-126
    • /
    • 2013
  • Due to the introduction of CR and DR, it has been neglected the use of the X-ray beam collimator and field size. This study examines nationwide survey of the proper use of collimator and field size by area in a specific field of plain radiography and the current status. Authors emphasized the need for the field size criteria, and propose a standard reference field size in each specific radiologic examination. Total 333 medical institutions (included in Seoul, Gyeonggi-do, Jeolla, Chungcheong, Gangwon-do, Busan area), were investigated in relation to the status of the X-ray beam collimation field size, type specific inspection areas, medical facilities, and image analyses by type to figure out whether they use the adjustment of image field to the specific examination. To assess the awareness and the impact of radiation exposure to the collimation adjustable, 168 radiographers who was working in 10 general hospitals, 10 hospitals, and 10 clinics, were surveyed how they haver adjusted the actual field size. We examine that 61.3% of medical institutions used the "Proper collimation" and only 49.9% of them employed proper one in lumbar spine densely crowded by major organs. 69% among general hospitals, and 65% among hospitals using DR system were using proper collimation. Radiographers recognized that proper adjustment of collimation could reduce the harmful radiation dose on patients. In the survey, 97.6% of respondents were aware of this fact, but only 83.3% of respondents did the adjustment of the size of the collimation field. The using of proper collimation field was low in the nationwide survey, so the effort to reduce the radiation dose on the patients is urgently needed. A unified standard for the field accompanied by thorough education should be needed.

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

DISTRIBUTION OF ABSORBED DOSES TO THE IMPORTANT ORGANS OF HEAD AND NECK REGION IN PANORAMIC RADIOGRAPHY (파노라마 촬영시 두경부 주요기관에 대한 흡수선량 분포)

  • Kim Byeong Sam;Choi Karp Shik;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.253-264
    • /
    • 1990
  • The purpose of this study was to estimate the distribution of absorbed doses of each important organs of head and neck region in panoramic radiography. Radiation dosimetry at internal anatomic sites and skin surfaces of phantom (RT-210 Humanoid Head & Neck Section/sup R/) was performed with lithium fluoride (TLD-100/sup R/) thermoluminescent dosimeters according to change of kilovoltage (65kVp, 75kVp and 85kVp) with 4 miliamperage and 20 second exposure time. The results obtained were as follows; Radiation absorbed doses of internal anatomic sites were presented the highest doses of 1.04 mGy, 1.065 mGy and 2.09 mGy in nasopharynx, relatively high doses of 0.525 mGy, 0.59 mGy and 1.108 mGy in deep lobe of parotid gland, 0.481 mGy, 0.68 mGy and 1.191 mGy in submandibular gland. But there were comparatively low doses of 0.172 mGy and 0.128 mGy in eyes and thyroid gland that absorbed dose was estimated at 85kVp. Radiation absorbed doses of skin surfaces were presented the highest doses of 1. 263 mGy, 1.538 mGy and 2.952 mGy in back side of first cervical vertebra and relatively high doses of 0.267 mGy, 0.401 mGy and 0.481 mGy in parotid gland. But there were comparatively low doses of 0.057 mGy, 0.068 mGy and 0.081 mGy in philtrum and 0.059 mGy in middle portion of chin that absorbed dose was estimated at 85kVp. According to increase of kilovoltage, the radiation absorbed doses were increased 1.1 times when kilovolt age changes from 65kVp to 75kVp and 1.9 times when kilovolt age changes from 75kVp to 85kVp at internal anatomic sites. According to increase of kilovoltage, the radiation absorbed doses were increased 1.3 times when kilovolt age changes from 65kVp to 75kVp and 1.6 times when kilovoltage changes from 75kVp to 85kVp at skin surfaces.

  • PDF

Efficacy of Physostigmine and Procyclidine as Combinational Prophylactics of Organophosphate Poisoning (Physostigmine과 procyclidine으로 구성된 복합예방제의 유기인제 해독효능)

  • Hur, Gyeung-Haeng;Choen, Ki-Cheol;Phi, Taek-San;Kim, Jae-Cheon;Hong, Dea-Sik;Park, Hoon;Jung, Chang-Hee;Lee, Yong-Han;Kim, Yun-Bae
    • Biomolecules & Therapeutics
    • /
    • v.9 no.1
    • /
    • pp.33-39
    • /
    • 2001
  • Antidotal efficacy of combinational prophylactics composed of physostigmine plus procyclidine, alone or in combination with antidotes such as atropine plus 2-pralidoxime or atropine plus HI-6, was evaluated in rats. Physostigmine (0.1 mg/kg) plus procyclidine (3 mg/kg), pretreated subcutaneously 30 min prior to subcutaneous exposure to organophosphates of militarily importance, exerted protection ratios of 7.2, 6.5, 4.0, 2.9 and 8.0 fold for tabun, saris, soman, cyclosarin and V-agent, respectively. In comparison, low effects (1.7 fold for soman and 1.3 fold for cyclosarin) were achieved with the traditional antidotes atropine (17.4 mg/kg) plus 2-pralidoxime (30 mg/kg) administered intramuscularly immediately after organophosphate, in contrast to high effects (5.5 fold for soman and 160.0 fold for cyclosarin) with atropine (17.4 mg/kg) plus HI-6 (125 mg/kg), although the protection ratio markedly decreased when treatment of antidotes was delayed. Note- worthy, the combinational prophylactics markedly potentiated the effects of antidotes to higher than 5.0 fold in all cases. In addition, the combinational prophylactics fully prevented the seizures and excitotoxic brain injuries induced by a high dose (100 mg/kg, 1.3 LD$_{50}$) of soman. Taken together, it is suggested that the prophylactics composed of physostigmine and procyclidine, in combination with posttreatment antidotes, could be a promising regimen for the prevention of lethality, seizures and brain injuries induced by organophosphates possessing diverse properties.s.

  • PDF

The Assessment of Acquired Dyschromatopsia among Organic-Solvents Exposed Workers (유기용제 폭로작업자들의 후천성 색각이상 평가)

  • Kang, Mi-Jung;Kang, Su-Hee;Suh, Suk-Kwon;Shin, Dong-Hoon;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.529-538
    • /
    • 1996
  • We investigated the occurrence of color vision loss in 70 organic solvent mixtures exposed workers and in 47 controls. Color Vision was assessed with a color arrangement test designed to identify the defective color sense, the Han Double 15-Hue Test. The results of the test were no significant difference between exposed workers and controls in the proportion of subjects who committed one or two errors. Quantitative analysis, using color confusion index(CCI), showed no signicant difference between exposed workers and controls. A significant linear correlation was present between age and CCI in both exposed workers (CCI=0.0056age + 0.94; r=0.23; p<0.05) and controls(CCI=0.0066age + 0.86; r=0.33; p<0.05). Qualitative analysis of the patterns on the hue circle showed that the prevalence of acquired dyschromatopsia was 21% in both and no significant difference. Multiple regression analyses showed that age was significantly related to color vision loss. These results did not provide evidence of a relationship between organic solvents exposure and incidence of color vision loss. In field studies for monitor the people at risk of the acquired color vision loss involving low-dose organic solvents exposed workers, both quantitative and qualitative information should be considered.

  • PDF

Differentiated Thyroid Carcinoma Risk Factors in French Polynesia

  • Xhaard, Constance;Ren, Yan;Clero, Enora;Maillard, Stephane;Brindel, Pauline;Rachedi, Frederique;Boissin, Jean-Louis;Sebbag, Joseph;Shan, Larrys;Bost-Bezeaud, Frederique;Petitdidier, Patrick;Drozdovitch, Vladimir;Doyon, Francoise;Rubino, Carole;de Vathaire, Florent
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2675-2680
    • /
    • 2014
  • Background: To investigate differentiated thyroid cancer risk factors in natives of French Polynesia is of interest because of the very high incidence of this cancer in the archipelago. Materials and Methods: To assess the role of various potential risk factors of thyroid cancer in the natives of French Polynesia we performed a case-control study. The study included almost all the French Polynesians diagnosed with differentiated thyroid carcinoma between 1981 and 2003 (n=229) and 373 French Polynesian control individuals from the general population without cancer. Results: Thyroid radiation dose received from nuclear fallout before the age of 15, a personal history of neck or/and head medical irradiation, obesity, tallness, large number of children, an artificial menopause, a familial history of thyroid cancer, a low dietary iodine intake, and having a spring as the main source of drinking water were found to be significant risk factors. No roles of smoking habits, alcohol consumption, iodine containing drugs, and exposure to pesticides were evidenced. Conclusions: Except for smoking, differentiated thyroid carcinoma risk factors in natives of French Polynesia are similar to those in other populations. Our finding on the role of having a spring as a drinking water origin is coherent with some other studies and could be due to geological factors.

Effect of Co-Culture with Mammalian Spermatozoa on Maturation in vitro of Porcine Cumulus-Free Germinal Vesicle Oocytes (난구세포가 제거된 돼지 미성숙 난자의 체외성숙에 포유동물 정자가 미치는 영향)

  • Kim, Byung-Ki;Kang, Sung-Ryoung;Yim, Cha-Ok;Han, Chang-Hee;Lee, Bok-Kyu;Lee, Kwang-Sun
    • Journal of Life Science
    • /
    • v.13 no.5
    • /
    • pp.732-739
    • /
    • 2003
  • The purpose of this study was to determine if the addition of spermatozoa into the culture medium could influence the nuclear maturation of denuded porcine germinal vesicle (GV) oocytes in vitro. Cumulus-oocyte complexes were collected from follicles of 3 to 5 mm in diameter, The cumulus and corona cells were removed from oocytes. Porcine denuded oocytes were cultured in tissue culture medium containing spermatozoa. After 48 h culture, oocytes were examined for the evidence of GV breakdown, metaphase I, anaphase-telophase I, and metaphase II (M II). The proportion of oocytes reaching M II stage was significantly (P<0.01) increased in the oocytes cultured in media containing spermatozoa compared to those in media without spermatozoa $(31.9\pm1.8%\; vs\; 14.9\pm1.0%)$.No differences in the rates of M II were observed among the different period of spermatozoa exposure nor among the spermatozoa from different species. The proportion of oocytes reaching M II stage was significantly different between high and low concentrations of spermatozoa. The present study suggests that mammalian spermatozoa contain a substance(s) that improves nuclear maturation in vitro of GV oocytes. Enhancing effect of spermatozoa for oocytes maturation in vitro is a highly dose-dependent.

Determination of Risk Ranking of Combination of Potentially Hazardous Foods and Foodborne Pathogens Using a Risk Ranger (Risk Ranger를 활용한 잠재적 위해식품과 미생물 조합에 대한 위해순위 결정)

  • Min, Kyung-Jin;Hwang, In-Gyun;Lee, Soon-Ho;Cho, Joon-Il;Yoon, Ki-Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.2
    • /
    • pp.91-99
    • /
    • 2011
  • Risk ranking must be determined for various hazards/food combinations to conduct microbial risk management effectively. Risk Ranger is a simple, easy-to-use calculation tool developed in Microsoft Excel and designed to rank the risk (low, medium, and high) for semi-quantitative microbial risk assessment. The user is required to answer 11 questions in Risk Ranger related to 1) severity of the hazard, 2) likelihood of a disease-causing dose of the hazard being present in the meal, and 3) the probability of exposure to the hazard in a defined time. This study determined the risk ranking for twenty three combinations of foodborne pathogens/potentially hazardous foods (PHFs) using a Risk Ranger. In this study, pathogenic E. coli in fresh cut produce salad was scored as 79, which was the highest rank among the 23 combinations of the foodborne pathogens and PHFs. On the other hand, zero risk was obtained with V parahaemolyticus in sushi, Salmonella in meat products and E. coli O157:H7 in hamburger patties. Although Risk Ranger is very simple method to rate the risk of foodborne pathogens and PHFs combination, the accuracy of result was mainly affected by the availability and accuracy of data in the literature. According to the result of literature review, the data are needed for contamination rate of raw materials, consumption amount/frequency of PHFs, and the effect of processing on pathogen. Risk ranking must be continuously revalidated with new data.

Atmospheric Dispersion Assessment for Potential Accidental Releases at Yonggwang Nuclear Power Plants (영광원전에서 가상 사고시 대기확산 평가)

  • Na, Man-Gyun;Sim, Young-Rok;Jung, Chul-Kee;Lee, Goung-Jin;Kim, Soong-Pyung;Chung, Sung-Tai
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.81-87
    • /
    • 2000
  • XOQ_DW code is currently used to assess the atmospheric dispersion fur the routine releases of radioactive gaseous effluents at Yonggwang nuclear power plants. This code was developed based on XOQDOQ code and an additional code is required to assess the atmospheric dispersion for potential accidental releases. In order to assess the atmospheric dispersion fer the accidental releases, XOQAR code has been developed by using PAVAN code that is based on Reg. Guide 1.145. The terrain data of XOQ_DW code inputs and the relative concentrations (X/Q) of XOQ_DW code outputs are used as the inputs of the XOQAR code through the interface with XOQ_DW code. By using this code, the maximum values of X/Q at exclusion area and low population zone boundaries except for sea areas were assessed as $1.33{\times}10^{-4}$ and $7.66{\times}10^{-6}$ sec/$m^3$, respectively. Through the development of this code, a rode system is prepared for assessing the atmospheric dispersion for the accidental releases as well as the routine releases. This developed code ran be used for other domestic nuclear power plants by modifying the terrain input data.

  • PDF