• Title/Summary/Keyword: Low Dose Exposure

Search Result 473, Processing Time 0.027 seconds

Adverse Effect of Nonylphenol on the Reproductive System in F1 Male Mice: A Subchronic Low-Dose Exposure Model

  • Kim, Yong-Bin;Cheon, Yong-Pil;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.23 no.2
    • /
    • pp.93-99
    • /
    • 2019
  • Nonylphenols (NPs) are widely used industrial materials, and are considered as potent endocrine disrupting chemical. Present study was undertaken to clarify the effect of subchronic low-dose NP exposure to F1 generation male mice. Mice were divided into 2 groups; (1) CON, control animals and (2) NP-50 ($50{\mu}g/L$), animals were treated with NP via drinking water. NP exposures were continuously conducted from parental pre-mating period until the postnatal day (PND) 55 of F1 offsprings. Mice were sacrificed on PND 55 and the tissue weights were measured. The initial body weights (at PND 21) and terminal body weights (PND 55) of the NP-50 animals were significantly lower than those of control animals (p<0.05). NP exposure induced a significant increase in the absolute weight of the testes (p<0.05). Conversely, the NP exposure caused significant decrease in the absolute weights of the epididymis (p<0.01), prostate (p<0.05) and seminal vesicle (p<0.05). Histopathological studies revealed that NP-treated animals exerted decreased seminiferous tubule diameters, reduced luminal area, and lower number of germ cells. Also some sloughing morphologies in the tubules were observed. In the caudal epididymis, fewer mature sperms and swollen epithelial cells were found in the NP-treated group. Our results confirmed that the subchronic low-dose NP exposure altered some male parameters and induced histopathological abnormalities in testis and epididymis of F1 mice. Since the NP dose used in this study is close to the average human daily NP exposure, our results could provide practically meaningful understanding of adverse effect of EDC in human.

Five Year's Follow-up of the Cardiovascular Disease Risk Factors among the Low Level Organic Solvent Exposure Workers (저농도 유기용제 노출 사업장 근로자의 심혈관질환 위험인자 변화 추적(2008~2012))

  • Kim, Mi-Ae
    • Korean Journal of Occupational Health Nursing
    • /
    • v.24 no.2
    • /
    • pp.67-75
    • /
    • 2015
  • Purpose: The objective of the present study was to evaluate the effects of occupational exposure to low dose organic solvents on the prevalence of cardiovascular risk factors. Methods: Study design was retrospective cohort study subjected on 191 exposures and 118 controls working in a petrochemical manufacture company. The eight indicators related to CVD risk were followed up for five years from 2008 to 2012. The risk level was compared during the follow up years and subject's characteristics, and the change of risk level were analyzed with repeated measures ANOVA and multiple logistic regression analysis. Results: At the start year 2008, the rate over cutoff value (ROCV) of BS (p<.001) and mean systolic BP (p=.017) were higher in organic solvent exposure group and the others showed no difference. And by the subject's characteristics, odds ratio of the ROCV of BS were higher in organic solvent exposure group and work shift group as 2.51 and 3.07. Comparing the results in 2012 to those of 2008, cardiovascular disease risk in organic solvent exposure group was about 1.5 times higher than that of in the control group. Conclusion: Gradual increase in the CVD risk was identified in organic solvent exposure group. However, the risk might be influenced by shift work and bad behaviors rather than organic solvent exposure.

Effects of Low Dose Gamma Irradiation on the Inflammatory Response in Spleen Cells (저선량 감마선 노출에 의한 비장세포의 염증 유발 작용에 대한 연구)

  • Sohn, Eun-Hwa
    • KSBB Journal
    • /
    • v.28 no.6
    • /
    • pp.415-422
    • /
    • 2013
  • Gamma irradiation (${\gamma}IR$) is widely used for radiotherapy as a treatment of cancer cells although it has a risk to damage normal cells. Inflammation is regarded as one of side effects of ${\gamma}IR$ while the effect of low dose of ${\gamma}IR$ on inflammation has not been researched well. Here, we investigated the inflammatory responses of low dose of ${\gamma}IR$ on murine spleen cells. It was evaluated if ${\gamma}IR$ affected the mitogen-induced lymphocyte proliferation, the regulation of various inflammatory cytokines (IFN-${\gamma}$, IL-2, IL-17, IL-4, IL-10), and the involvement of Ikaros and MAPK/NF-${\kappa}B$ medicated mechanism. Exposure of $^{137}Cs-{\gamma}IR$ below 2 Gy decreased the lymphocytes proliferative response to mitogens (LPS, ConA) except at the lowest dose, 0.05 Gy. IL-17, IL-2 and IL-4 mRNA increased at 0.5 and 2 Gy, but not altered at 0.05 Gy. IL-10, anti-inflammatory cytokine, increased only at 0.05 Gy. In regard to intracellular signaling, p-JNK, p-p38 and p-$I{\kappa}B{\alpha}$ were not changed, whereas the activation of ERK and Ikaros increased at the lowest dose. These results suggest that exposure of ${\gamma}IR$ less than 0.5 Gy (or below 0.05 Gy) has beneficial effects as a radiation hormesis on immune function.

A Study on the Reduction of Cosmic Radiation Exposure by Flight Crew (항공승무원의 우주방사선 피폭 저감에 관한 연구)

  • Ahn, Hee-Bok;Kim, Kyu-Wang;Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • The purpose of this study is to analyze the radiation dose data of the space crew of the flight crew and to present a plan for the health management of the flight crew on the basis of the analysis. The analysis show that the average exposure dose of the flight attendants continued to rise, and the exposure dose of the flight attendants was five(5) times higher than that of the radiation workers. As a way to reduce the effects of cosmic radiation, this paper suggests appropriate personnel allocation by model, balanced allocation of high and low latitude routes by crew according to the aircraft type, and a low altitude flight plan for high latitude flight. This study will help aviation crew members understand cosmic radiation and trust in the company's policies. In the future, it will be necessary to enhance the flight safety of the crew by deriving meaningful results by analyzing data related to cosmic radiation of various routes.

Analysis of Cosmic Radiation Exposure for Domestic Flight Crews in Korea

  • Ahn, Hee-Bok;Hwang, Junga;Kwak, Jaeyoung;Kim, Kyuwang
    • Journal of Astronomy and Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.51-57
    • /
    • 2022
  • Cosmic radiation exposure of the flight crews in Korea has been managed by Radiation Safety Management around Living Life Act under Nuclear Safety and Security Commission. However, the domestic flight crews are excluded from the Act because of relatively low route dose exposure compared to that of international flight crews. But we found that the accumulated total annual dose of domestic flight crews is far from negligible because of relatively long total flight time and too many flights. In this study, to suggest the necessity of management of domestic flight crews' radiation exposure, we statistically analyzed domestic flight crew's accumulative annual dose by using cosmic radiation estimation models of the Civil Aviation Research Institute (CARI)-6M, Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS), and Korean Radiation Exposure Assessment Model (KREAM) and compared with in-situ measurements of Liulin-6K LET spectrometer. As a result, the average exposure dose of domestic flight crews was found to be 0.5-0.8 mSv. We also expect that our result might provide the basis to include the domestic flight crews as radiation workers, not just international flight attendants.

A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes

  • Cho, Jae-Hun;Kim, Jae-Yun;Kang, Joo-Eun;Park, Pyong-Eun;Kim, Jae-Hun;Lim, Jeong-Ae;Kim, Hae-Kyoung;Woo, Nam-Sik
    • The Korean Journal of Pain
    • /
    • v.24 no.4
    • /
    • pp.199-204
    • /
    • 2011
  • Background: Although many clinicians know about the reducing effects of the pulsed and low-dose modes for fluoroscopic radiation when performing interventional procedures, few studies have quantified the reduction of radiation-absorbed doses (RADs). The aim of this study is to compare how much the RADs from a fluoroscopy are reduced according to the C-arm fluoroscopic modes used. Methods: We measured the RADs in the C-arm fluoroscopic modes including 'conventional mode', 'pulsed mode', 'low-dose mode', and 'pulsed + low-dose mode'. Clinical imaging conditions were simulated using a lead apron instead of a patient. According to each mode, one experimenter radiographed the lead apron, which was on the table, consecutively 5 times on the AP views. We regarded this as one set and a total of 10 sets were done according to each mode. Cumulative exposure time, RADs, peak X-ray energy, and current, which were viewed on the monitor, were recorded. Results: Pulsed, low-dose, and pulsed + low-dose modes showed significantly decreased RADs by 32%, 57%, and 83% compared to the conventional mode. The mean cumulative exposure time was significantly lower in the pulsed and pulsed + low-dose modes than in the conventional mode. All modes had pretty much the same peak X-ray energy. The mean current was significantly lower in the low-dose and pulsed + low-dose modes than in the conventional mode. Conclusions: The use of the pulsed and low-dose modes together significantly reduced the RADs compared to the conventional mode. Therefore, the proper use of the fluoroscopy and its C-arm modes will reduce the radiation exposure of patients and clinicians.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Preliminary Evaluation of Radiological Impact for Domestic On-road Transportation of Decommissioning Waste of Kori Unit 1

  • Dho, Ho-Seog;Seo, Myung-Hwan;Kim, Rin-Ah;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.4
    • /
    • pp.537-548
    • /
    • 2020
  • Currently, radioactive waste for disposal has been restricted to low and intermediate level radioactive waste generated during operation of nuclear power plants, and these radioactive wastes were managed and disposed of the 200 L and 320 L of steel drums. However, it is expected that it will be difficult to manage a large amount of decommissioning waste of the Kori unit 1 with the existing drums and transportation containers. Accordingly, the KORAD is currently developing various and large-sized containers for packaging, transportation, and disposal of decommissioning waste. In this study, the radiation exposure doses of workers and the public were evaluated using RADTRAN computational analysis code in case of the domestic on-road transportation of new package and transportation containers under development. The results were compared with the domestic annual dose limit. In addition, the sensitivity of the expected exposure dose according to the change in the leakage rate of radionuclides in the waste packaging was evaluated. As a result of the evaluation, it was confirmed that the exposure dose under normal and accident condition was less than the domestic annual exposure dose limit. However, in the case of a number of loading and unloading operations, working systems should be prepared to reduce the exposure of workers.

Expressional Changes of Connexin Isoform Genes in the Rat Caput Epididymis Exposed to Flutamide or Estradiol Benzoate at the Early Postnatal Age

  • Lee, Ki-Ho
    • Development and Reproduction
    • /
    • v.21 no.3
    • /
    • pp.317-325
    • /
    • 2017
  • Direct communication between neighboring cells through connexin (Cx)-based gap junction is a crucial biological manner to regulate functions of a tissue consisting of multi-cell types. The present research evaluated expressional changes of Cx isoforms in the caput epididymis of adult rat exposed to estradiol benzoate (EB) or flutamide (Flu) at the early postnatal age. A single subcutaneous administration of EB at a low-dose [$0.015{\mu}g/kg$ body weight (BW)] or a high-dose ($1.5{\mu}g/kg\;BW$) or Flu at a low-dose ($500{\mu}g/kg\;BW$) or a high-dose (5 mg/kg BW) was performed to an animal at 1 week of age. Quantitative real-time PCR analysis was employed to determine expressional changes of Cx isoforms. The transcript levels of Cxs30.3 and 37 were decreased by a low-dose EB treatment, while decreases of Cxs31, 31.1, 32, 40, and 45 transcript levels were observed with a low-dose EB treatment. The treatment of a high-dose EB resulted in expressional reduction of Cxs30.3, 31, 31.1, 37, 40, 43, and 45. The Flu treatment at a low dose caused increases of Cxs26, 37, and 40 transcript levels but decreases of Cxs31.1, 43, and 45 transcript levels. Increases of Cxs30.3, 31, 37, and 40 mRNA amounts were induced by a high-dose Flu treatment. However, exposure to a high-dose Flu produced expressional decreases of Cxs31.1, 32, and 43 in the adult caput epididymis. These observations suggest that exposure to EB or Flu at the neonatal period could lead to aberrant expression of Cx isoforms in the adult caput epididymis.

Modification of Gene Expression of Connexins in the Rat Corpus Epididymis by Estradiol Benzoate or Flutamide Exposure at the Early Neonatal Age

  • Lee, Ki-Ho
    • Development and Reproduction
    • /
    • v.19 no.2
    • /
    • pp.69-77
    • /
    • 2015
  • Cell-cell direct communication through channel-forming molecules, connexin (Cx), is essential for a tissue to exchange signaling molecules between neighboring cells and establish unique functional characteristics during postnatal development. The corpus epididymis is a well-known androgen-responsive tissue and involves in proper sperm maturation. In the present research, it was attempted to determine if expression of Cx isoforms in the corpus epididymis in the adult is modulated by exposure to estrogenic or anti-androgenic compound during the early postnatal period. The neonatal male rats at 7 days of age were subcutaneously injected by estradiol benzoate (EB) at low-dose ($0.015{\mu}g/kg$ body weight) or high-dose ($1.5{\mu}g/kg$ body weight) or flutamide (Flu) at low-dose ($500{\mu}g/kg$ body weight) or high-dose (50 mg/kg body weight). The corpus epididymis collected at 4 months of age was subjected to evaluate expressional changes of Cx isoforms by quantitative real-time PCR. Treatment of low-dose EB resulted in increases of Cx32, Cx37, and Cx45 transcript levels, while exposure to high-dose EB decreased expression of Cx26, Cx30.3, Cx31, Cx31.1, Cx32, Cx40, Cx43, and Cx45. Treatments of Flu caused significant decreases of expression of all examined Cx isoforms, except Cx37 and Cx43 shown no expressional change with high-dose Flu treatment. These findings imply that expression of most Cx isoforms present in the corpus epididymis would be transcriptionally regulated by actions of androgen and/or estrogen during postnatal period.