• 제목/요약/키워드: Low Dose Exposure

검색결과 473건 처리시간 0.022초

골밀도검사에서 피검자의 장기선량 측정 및 차폐기구의 효용성 평가 (Evaluation of the Effectiveness of the Shielding Device and the Organ Dose of Subject During Bone Mineral Density)

  • 조용인;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.187-194
    • /
    • 2020
  • Bone mineral density is a examination to measure the amount of bone in patients with metabolic bone disease. It is a low dose, but may cause unnecessary exposure to the gonads and other organs located in the periphery when examining the lumbar and proximal femurs. Therefore, the purpose of this study was to evaluated the exposure dose for each organ exposed during the bone mineral density through simulation, and analyzed the applicability of the subject to radiation shielding devices using 3D printing materials. As a result, the highest dose was shown at 11.47 uSv in the breast during lumbar examination and 8.98 uSv in the testis during proximal femur examination. Also, the farther away from the examination site, the lower the effect of the scattering-ray. The shielding effect of using 3D printing shielding device showed high results in proportion to the effective atomic number and specific gravity of the printing material. Among the printing materials, ABS + W showed an effect of at least 78.72 to 96.3 9% compared to the existing lead material.

MCNPX 시뮬레이션을 이용한 무납 방사선 차폐 시트 기반의 공간산란 저감화 평가 (Evaluating the Reduction of Spatial Scattering based on Lead-free Radiation Shielding Sheet using MCNPX Simulation)

  • 양승우;박금별;허예지;박지군
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.367-373
    • /
    • 2020
  • 물체와 X선의 상호작용로 발생하는 산란선으로 야기되는 공간 산란선량은 대부분이 저에너지 영역의 전자기파로 인체에 비교적 쉽게 흡수되어 방사선 피폭정도가 증가하게 된다. 이러한 공간 산란 선량은 방사선작업 종사자 및 환자의 방사선 피폭 정도 지표로도 사용되고 있으며 간접적으로 발생하는 공간 산란 선량을 줄여 피폭을 저감화하기 위한 방안의 필요성이 마련될 필요성이 있다. 이에 본 연구에서는 공간산란 선량을 저감화 방안으로 무납 방사선 차폐 시트를 제시하였고 가슴 X선 촬영검사를 기준으로 몬테카를로(MC; Monte Carlo) 시뮬레이션을 수행하여 거리 변화에 따른 갑상샘과 생식선 위치에서 흡수되는 산란선의 흡수선량을 산출하였고 실측치와 차폐율을 비교 평가하였다.

Prolonged low-dose cyclophosphamide treatment after pulse therapy attenuates lung injury in rats with paraquat intoxication

  • Gao, Jie;Feng, Shunyi;Li, Yong
    • The Korean journal of internal medicine
    • /
    • 제33권6호
    • /
    • pp.1137-1142
    • /
    • 2018
  • Background/Aims: This study tested the hypothesis that prolonged low-dose cyclophosphamide (CTX) treatment after pulse therapy attenuate paraquat (PQ)-induced lung injury in rats. Methods: PQ (25 mg/kg) was administered intraperitoneally to induce PQ-intoxicated rat model. The rats were randomly divided into four groups: control group (1 mL/day saline solution for 14 days), PQ group (1 mL/day saline solution for 14 days after PQ exposure), pulse group (15 mg/kg/day CTX in 1 mL of saline solution for 2 days and subsequent 1 mL/day saline solution for 12 days), and prolonged low-dose group (15 mg/kg/day CTX in 1 mL of saline solution for 2 days and subsequent 1.5 mg/kg/day CTX in 1 mL of saline solution for 12 days). A 14-day follow-up was conducted to determine the survival rat, and lung hydroxyproline (HYP), wet-to-dry weight ratios (W/Dc) and histopathological changes were evaluated. Results: Results showed similar survival rate (55% vs. 50%, p > 0.05) between prolonged low-dose and pulse groups. Lung W/Dc ($4.94{\pm}0.38$ vs. $5.47{\pm}0.28$, p < 0.01), HYP ($3.34{\pm}0.29{\mu}g/mg$ vs. $3.65{\pm}0.19{\mu}g/mg$, p < 0.001), and fibrosis score ($2.69{\pm}0.84$ vs. $3.13{\pm}0.63$, p < 0.05) were lower in prolonged low-dose group than those in the pulse group. Conclusions: These findings suggested prolonged low-dose CTX treatment after pulse therapy could attenuate PQ-induced lung injury in rats.

CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용 (Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.941-946
    • /
    • 2019
  • 환자의 진단 및 치료를 결정할 때 전산화단층촬영 (computed tomography; CT)은 우수한 해부학 정보를 제공하기 때문에 진단에 큰 도움이 되어 있다. 그에 따른 사용빈도가 증가하고 있으며, 활용 및 응용범위도 확대되어가는 추세이다. 저관전압을 사용해서 CT 검사를 하면 노이즈가 증가한다. 기존의 여러 연구에서는 영상재구성법에 대한 노출조건을 조절하는 방법 등을 시도해서 최적의 화질을 찾는 방법을 찾고 있으나 근본적 문제해결은 되지 못한다. 입력 영상의 신호를 유지하고 노이즈만을 최대한 제거하기 위해서 이중 트리웨이블릿 알고리즘을 적용하였다. 실험결과 100kVp, 회전시간 0.5sec의 영상에서 complex oriented 2d 방을 사용 할 경우 노이즈는 8.53에서 4.51로 줄어들었다. 본 연구를 통해서 저관전압 두부 CT에서 발생하는 높은 수준의 노이즈를 최적의 노이즈제거 알고리즘으로 노이즈를 제거하고 환자선 량을 낮출 수 있었다. 본 연구결과를 임상에서 사용 시 저선량의 CT 사용이 가능하고 환자 피폭을 줄일 것으로 판단한다.

치과위생사의 방사선 촬영업무의 확대에 대한 문헌적 고찰 (A literature review on expansion of dental hygienists' radiography operations)

  • 최영숙;김진경;장종화;박용덕
    • 한국치위생학회지
    • /
    • 제9권2호
    • /
    • pp.111-124
    • /
    • 2009
  • This study analyzes through the review of literature and laws the exposure time, clinical frequency, and radiation exposure of intraoral and extraoral radiography as well as of panoramic radiography performed by dental hygienists in dental clinics, compares the dental radiology curriculums of radiological science and dental hygiene departments, and proposes the expansion of dental hygienists' radiography operations. The radiology curriculums were compared between the radiological science and dental hygiene departments of colleges. For new analysis by radiography for dental diagnosis, the exposure time, radiation absorbed dose, effective dose, and number of days of natural radiation were compared by the type of oral radiation films and radiographical techniques proposed by domestic and international studies. The exposure time of panoramic radiography is 15 seconds and it takes about two minutes for completion, whereas the exposure time of the standard radiography is 0.2~0.8 seconds and it takes 10 times longer for completion of the radiography of full mouth than the panoramic radiography. The standard radiography can cause distortions of radiation at severely curved parts of dental arch and palatopharyngeal reflex. However, panoramic radiography can be performed even for lock jaw patients, causes less inconvenience to patients and is much simpler than the standard radiography. The percentage of dental clinics where radiography is performed by dental hygienists was 92.0%, and the percentage of standard film radiography by dental hygienists was 98% whereas the percentage of panoramic radiography by dental hygienists was 92%. For the absorbed dose which is an indicator of radiation exposure, the When the effective dose which is an indicator of the danger of radiation exposure was converted to the number of days of natural radiation, it was 3.3 days for panoramic radiography, but 13.9 days for the full mouth standard radiography by bisecting angle technique which was 4.2 times longer than the panoramic radiography. There were two colleges that had a dental radiology course with two credits in the departments of radiological science. The credits for dental radiology courses in the department of dental hygiene ranged varied by college, ranging from 3 to 8; on average, the theory course was 2.2 credits and the practice course was 2.02 credits. To summarize the above results, the percentage of dental clinics where panoramic radiography is performed by dental hygienists under the guidance of dentists is high. Panoramic radiography has become an essential facility for dental clinics. It is faster than standard film radiography and less dangerous due to low radiation exposure. Panoramic radiography is a simple mechanical job that does not require training of oral radiography by radiotechnologist. Because panoramic radiography is one of major operations which must be performed at all times in dental clinics, it must be designated as intraoral technique rather than extraoral technique, or legalized for inclusion in the scope of operations of dental hygienists.

  • PDF

쥐 심실에서 Digitalis Receptor Desensitization에 관한 연구 (Studies on Digitalis Receptor Desensitization in Rat Ventricle)

  • 이신웅;이정수;장태수
    • Biomolecules & Therapeutics
    • /
    • 제2권2호
    • /
    • pp.114-119
    • /
    • 1994
  • [$^3$H]Ouabain binding parameters ( $K_{D}$ and $B_{max}$) to control rat ventricular strips and Langendorff preparations which were not previously exposed to ouabain were compared with those to both preparations that had been first exposed to a complete ouabain dose range of dose-response curve (10$^{-8}$ to 10$^{4}$M). In rat ventricular strips and Langendorff perfused heart preparations, cumulative dose-response curves of ouabain revealed biphasic positive inotropic effects, a "low-dose" effect and a "high-dose" effect with E $d_{50}$ values of 0.5 $\mu$M and 35 $\mu$M ouabain, respectively. The "low-dose" effect in ventricular strip disappeared or was diminished significantly when the ouabain dose-response curve was repeated after the washout of the effects of the first dose-response curve, whereas there were no significant differences in the maximal "high-dose"effect in both exposures to oubain. However, both of the control and ouabain-preexposed Langendorff perfused hearts revealed the same low-dose effects. The $K_{D}$ value for [$^3$H] ouabain binding and the ouabain binding site concentration ( $B_{max}$) estimated by [$^3$H]ouabain displacement assay in control preparations were 230 nM and 2 pmol/mg protein, respectively. [$^3$H]Ouabain binding parameters were not changed by repeated exposure to high concentrations of ouabain. These results suggest that digitalis receptor desensitization in the rat ventricular strip may due to the change of post-receptor events induced by ouabain binding to a high affinity site ($\alpha$$_2$isoform).).).).).

  • PDF

경주 중·저준위방사성폐기물 처분시설의 방폐물검사건물에서 해체 방사성폐기물 대상 방사선작업종사자의 피폭선량 평가 및 작업조건 도출 (The Assessment of Exposure Dose of Radiation Workers for Decommissioning Waste in the Radioactive Waste Inspection Building of Low and Intermediate-Level Radioactive Waste Disposal Facility)

  • 김린아;도호석;김태만;조천형
    • 방사성폐기물학회지
    • /
    • 제18권2_spc호
    • /
    • pp.317-325
    • /
    • 2020
  • 한국원자력환경공단은 처분시설 내 1단계 인수·저장구역의 인수검사 공간 및 드럼 취급 공간 부족에 대한 문제를 해결하기 위하여 방폐물검사건물을 건설하여 저장·처리능력을 확충할 예정이다. 본 연구에서는 MCNP 코드를 이용하여 방폐물검사건물 내 저장구역에서 취급하는 해체 방사성폐기물 대상 신형처분용기를 대상으로 작업종사자의 피폭선량을 평가하였다. 평가결과, 시설 내 저장 가능한 최대 용기 개수(304개)와 방사선작업에 대한 연간 예상 작업시간(약 306시간)에 대하여 연간 집단선량은 총 84.8 man-mSv로 계산되었다. 시설 내 총 304개의 신형처분용기(소형/중형 타입)가 저장 완료된 시점에서 인수검사, 처분검사를 위한 작업종사자의 투입인력은 총 25명, 작업종사자 당 예상피폭선량은 연평균 3.39 mSv로 산출되었다. 소형용기 취급 시 작업종사자의 고방사선량 작업에 따른 작업효율과 방사선적 안전성 확보를 위해서는 콘크리트 라이너의 두께를 증가시키는 추가적인 차폐가 필요할 것으로 평가되었다. 향후 본 연구를 바탕으로 실측기반의 해체폐기물의 선원항과 특성을 활용하여 방사선작업 당 작업시간 및 투입인력을 산출함으로써 작업종사자의 최적의 방사선작업조건을 도출할 수 있을 것으로 사료된다.

Low Dose Effect와 Non Monotonic Dose Responses(NMDRs) 그리고 의학적 의미 - 용량-반응관계의 새로운 패러다임을 중심으로 - (Low Dose Effect and Non Monotonic Dose Responses(NMDRs) and its Medical Meaning - Focusing on A New Paradigm of Dose-Response Relationship -)

  • 성 안젤라동민;신지연;이승은;박송미;오연지;이선동
    • 대한예방한의학회지
    • /
    • 제20권1호
    • /
    • pp.145-159
    • /
    • 2016
  • Objectives : The aim was to investigate the characteristics of low dose effect and non monotonic dose responses(NMDRs) and to predict the influence it might have on the health and medicine, traditional Korean medicine. Methods : By investigating recently published major literatures related to low dose effect and NMDRs, the definition, mechanism, major related fields, and the influence on public health and medicine has been categorized and summarized. Results : Although there are still heated debates about the definition of low dose, it implies the biological responses in environmental exposure level and the NDMDRs means the nonlinear relationship between the dose-response in the slope sign change. Also, it implies the new form of the curve showing a U, reverse U shape, and the slop sign constantly changing showing various forms. This mechanism is because the two acceptor shows opposing effects to toxic materials and the affinity is different along with the numerical value that increase and decrease being different. These characteristics generally appear in endocrine disrupters such as bisphenol A, agricultural pesticides, metal, and radiation. The research field in the public health and medical treatment is obesity, problems in metabolism, growth hormone treatment, climacteric treatment, breast cancer, intake of Korean traditional medicine for pregnancy, menopause and phytoestrogen. Conclusions : As a result of discussing implications, NMDRs is a particular effect in low dose and heated debates surround this response, research is being conducted surrounding the field of obesity, problems in metabolism, growth hormone treatment, climacteric treatment, breast cancer, intake of Korean traditional medicine for pregnancy, menopause, and phytoestrogen. More research and interest in needed as it can have a massive influence in the public health and medicine.

디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가 (Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image)

  • 이진수;고성진;강세식;김정훈;김동현;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제13권8호
    • /
    • pp.275-283
    • /
    • 2013
  • 자동노출제어장치를 사용하는 흉부 후전 검사는 이온전리조의 선택에 따라 환자가 받는 피폭선량이 달라진다. 본 논문에서는 자동노출제어장치의 이온전리조의 선택에 따른 최적의 진단 영상을 획득하면서 피폭선량을 최소화하는 방안에 대해 연구하였다. 실험방법은 흉부 후전 검사와 동일한 조건으로 자동노출제어장치의 이온전리조 선택과 감도변화에 따라 실험하였다. 이온전리조의 상단 2개, 하단 1개의 센서를 on/off 선택에 따라 7가지의 경우로 나누어 각각 5회씩 측정하여 평균값을 구하고 피폭선량을 산출하였다. 영상평가는 변조전달함수, 최대신호 대 잡음비, 평균제곱근, 신호 대 잡음비, 대조도 대 잡음비, 평균대표준편차비를 각각 측정하여 평가를 시행하였다. 실험결과 피폭선량 평가에서 이온전리조 상단 2개를 선택한 경우가 다른 조합에 비해 가장 낮은 선량을 나타내었고, 해상력 평가결과로는 감도 625(High)에서 상단2개를 선택한 영상이 두 번째로 높은 공간주파수 1.343 lp/mm를 나타내었다. 상단 2개를 선택한 영상의 평균제곱근 결과값이 두 번째로 낮게 나타났으며, 신호 대 잡음비, 대조도 대 잡음비, 평균 대 표준편차비는 두 번째로 높은 결과값을 나타내었다. 그리고 감도가 증가함에 따라 피폭선량은 감소하였으며, 영상품질 측면에서도 보다 우수한 영상을 얻을 수 있었다. 따라서 피폭선량을 최소화하고, 최적의 의료 영상을 얻기 위해서는 감도 625(High)에서 이온전리조 상단 2개를 선택하는 것이 임상적으로 유용할 것으로 사료된다.

뇌혈관 중재적 시술에서 차폐체를 이용한 시술자의 피폭선량과 화질에 관한 연구 (Study on Exposure Dose and Image Quality of Operator Using Shielding Material in Neuro Interventional Radiology)

  • 김대호;김상현;이영진;임종천;한동균
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.579-587
    • /
    • 2017
  • 중재적 시술은 매우 낮은 관전류를 사용함에도 불구하고 장시간 방사선 피폭으로 인해 시술자뿐만 아니라 환자의 방사선 노출에 의한 위험도가 크다. 이에 본 연구의 목적은 뇌혈관 중재적 시술 시 시술자가 받는 선량을 측정하고 의료 방사선으로부터의 노출을 효율적으로 차단할 수 있는 차폐물질과 차폐방식을 찾아 시술자가 받는 피폭선량을 화질에 영향을 미치지 않는 범위 내에서 최소화 할 수 있는 방법을 찾는 것이다. 결과적으로, Nano Tungsten 물질로 새롭게 고안한 차폐방식을 사용하였을 때 시술자 측에서 평균 7.95% 선량이 감소되는 것을 확인할 수 있었다. 또한, 본 연구에서 고안한 차폐체를 사용하였을 때 PSNR의 결과는 38.44 dB로 측정되었으며 이는 Nano Tungsten이 영상의 화질에 큰 영향을 끼치지 않는 것으로 확인할 수 있었다. 결론적으로, Nano Tungsten 차폐물질은 화질에 영향을 미치지 않는 범위 내에서 시술자뿐만 아니라 환자의 선량을 상당히 줄일 수 있음을 알 수 있었다. 위의 물질을 사용할 경우 최근 차폐물질의 이슈로 부각되고 있는 인체 및 환경의 유해성 및 경제성에 관련한 문제점들을 해결할 수 있을 것으로 기대된다.