• 제목/요약/키워드: Low Dose

검색결과 2,887건 처리시간 0.033초

Low-dose metronomic doxorubicin inhibits mobilization and differentiation of endothelial progenitor cells through REDD1-mediated VEGFR-2 downregulation

  • Park, Minsik;Kim, Ji Yoon;Kim, Joohwan;Lee, Jeong-Hyung;Kwon, Young-Guen;Kim, Young-Myeong
    • BMB Reports
    • /
    • 제54권9호
    • /
    • pp.470-475
    • /
    • 2021
  • Low-dose metronomic chemotherapy has been introduced as a less toxic and effective strategy to inhibit tumor angiogenesis, but its anti-angiogenic mechanism on endothelial progenitor cells (EPCs) has not been fully elucidated. Here, we investigated the functional role of regulated in development and DNA damage response 1 (REDD1), an endogenous inhibitor of mTORC1, in low-dose doxorubicin (DOX)-mediated dysregulation of EPC functions. DOX treatment induced REDD1 expression in bone marrow mononuclear cells (BMMNCs) and subsequently reduced mTORC1-dependent translation of endothelial growth factor (VEGF) receptor (Vegfr)-2 mRNA, but not that of the mRNA transcripts for Vegfr-1, epidermal growth factor receptor, and insulin-like growth factor-1 receptor. This selective event was a risk factor for the inhibition of BMMNC differentiation into EPCs and their angiogenic responses to VEGF-A, but was not observed in Redd1-deficient BMMNCs. Low-dose metronomic DOX treatment reduced the mobilization of circulating EPCs in B16 melanoma-bearing wild-type but not Redd1-deficient mice. However, REDD1 overexpression inhibited the differentiation and mobilization of EPCs in both wild-type and Redd1-deficient mice. These data suggest that REDD1 is crucial for metronomic DOX-mediated EPC dysfunction through the translational repression of Vegfr-2 transcript, providing REDD1 as a potential therapeutic target for the inhibition of tumor angiogenesis and tumor progression.

Lung Cancer Screening With Low-dose Chest Computed Tomography: Experience From Radon-contaminated Regions in Kazakhstan

  • Panina, Alexandra;Kaidarova, Dilyara;Zholdybay, Zhamilya;Ainakulova, Akmaral;Amankulov, Jandos;Toleshbayev, Dias;Zhakenova, Zhanar;Khozhayev, Arman
    • Journal of Preventive Medicine and Public Health
    • /
    • 제55권3호
    • /
    • pp.273-279
    • /
    • 2022
  • Objectives: The aim of this study was to present the baseline results of a pilot project conducted to evaluate the effectiveness of lung cancer screening using low-dose chest computed tomography (CT) in regions with excessive radon levels in the Republic of Kazakhstan. Methods: In total, 3671 participants were screened by low-dose chest CT. Current, former, and never-smokers who resided in regions with elevated levels of radon in drinking water sources and indoor air, aged between 40 and 75 with no history of any cancer, and weighing less than 140 kg were included in the study. All lung nodules were categorized according to the American College of Radiology Lung Imaging Reporting and Data System (Lung-RADS 1.0). Results: Overall, 614 (16.7%) participants had positive baseline CT findings (Lung-RADS categories 3 and 4). Seventy-four cancers were detected, yielding an overall cancer detection rate of 2.0%, with 10.8% (8/74) stage I and a predominance of stage III (59.4%; 44/74). Women never-smokers and men current smokers had the highest cancer detection rates, at 2.9% (12/412) and 6.1% (12/196), respectively. Compared to never-smokers, higher odds ratios (ORs) of lung cancer detection were found in smokers (OR,2.48; 95% confidence interval [CI], 1.52 to 4.05, p<0.001) and former smokers (OR, 2.32; 95% CI, 1.06 to 5.06, p=0.003). The most common histologic type of cancer was adenocarcinoma (58.1%). Conclusions: Implementation of low-dose CT screening for lung cancer in regions with elevated radon levels is an effective method for both smokers and never-smokers.

Low Dose Ultraviolet Al (340-400 nm) Phototherapy for Erythrodermic Cutaneous T-cell Lymphoma

  • Uede, Koji;Hiroi, Akihisa;Nakamura, Tomoyuki;Kishi, Tomoo;Yamamoto, Yuki;Furukawa, Fukumi
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.503-505
    • /
    • 2002
  • Three patients suffering from widespread erythrodermic cutaneous T-cell lymphoma were treated with low-dose UVAI phototherapy with a single dose of 20 - 30J/$cm^2$, resulting in cumulative doses of 520 - 1890 J/$cm^2$. Two patients showed complete responses, while other had a partial improvement.

  • PDF

$^{60}/Co-${\gamma}$$선으로 조사된 이축연신 폴리프로필렌 필림의 온도 및 전압에 따른 유전특성 (The Dielectric Properties due to the Temperature and Applied Voltage of Oriented Polypropylene Film Irradiated by $^{60}/Co-${\gamma}$$)

  • 홍진웅;이수원;김왕곤
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.48-55
    • /
    • 1994
  • In this paper, It is studied that the variation of the dielectric absorption of the specimen according to the change with $^{60}$ Co-${\gamma}$ ray irradiation dose of the influence of temperature and applied voltage. In order to investigate the effect of irradiated oriented polypropylene film, we have observed dielectric properties within the temporature range of 30~130 ($^{\circ}C$) and voltage range of 100~250 (V). As for the dependency of temperature by tan $\delta$, the $\alpha$ peak which appears at high temperature increases accordingly to the increment of irradiation dose which is contributed by the crystal region and moves towards the high temperature. The $\beta$ peak which appears the orientation by dipoles and molecular motions in the amorphous region at low temperature. For the dependency of voltage by tan $\delta$ at low temperature, the peak of the tan $\delta$ shifts accordingly to the increment of irradiation dose towards the high temperature region.

  • PDF

변압기유의 유전특성에 미치는 저조사량 전자선의 영향 (II) (The Effect of the Electron Beam with a Low Dose on the Dielectric Characteristics of Transformer Oils (II))

  • 이용우;조돈찬;신종열;김왕곤;홍진웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1559-1561
    • /
    • 1996
  • In this experiment, it is decided to irradiated with a low dose of electron beam. Such that being things, the specimen is produced by the different dose, for example, 0.5[Mrad], 1[Mrad], 2[Mrad] except for original specimen. From the result of the analysis for the physical properties using FT-IR spectrum, it is confirmed that carbonyl groups of irradiated specimen is increased more than that of non-irradiated specimen. And all of nitric compound are disappeared by irradiating with electron beam. From the result of the dielectric characteristics, the specimen irradiated with 2[Mrad] is excellent.

  • PDF

한국인 수유부에 어유의 보충 급여 효과에 관한 연구 - II. 모유의 지질 농도 및 지방산 조성에 미친 영향- (Effects of Fish Oil Supplementation to Korean Lactasting Women -II. The Effects on Lipid Content and Fatty Acid Composition of Breast Milk-)

  • 임현숙
    • Journal of Nutrition and Health
    • /
    • 제29권2호
    • /
    • pp.188-191
    • /
    • 1996
  • This study was undertaken to determine the effects of fish oil supplementation with low dose on the lipid content and fatty acid composition of breast milk. Among 18 lactating women who were exclusively breast-fed their babies, 6 were in control group and 12 were in fish lil groups. The subjects in fish oil groups were supplemented with 1.96g/d or 3.92g/d of fish oil for 2 weeks from 10 to 12 weeks of postpartum. All subjects consumed their usual diet at home. Breast milk samples were collected at the final day of experiment. By fish oil supplementation, the concentrations of triglyceride, cholesterol, free fatty acid and phospholipid as well as total lipid in breast milk tended to increase, but not significant. There was no dose-dependent response. The fatty acid composition of breast milk was not changed by fish oil supplementation. These results suggest that low dose of fish oil supplementation may increase of lipid content, but does not affect on the fatty acid composition of breast milk.

  • PDF

저조사량 전자선에 대한 변압기유의 체적고유저항 특성 (The Characteristics of Volume Resistivity for the Transformer Oil irradiated with the Electron Beam of Low Dose)

  • 이용우;이우영;조돈찬;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.211-215
    • /
    • 1996
  • In this paper, the volume resistivity of transformer oil is made researches so that the electrical properties for transformer oil is investigated. The specimen is produced by the irradiation of electron beam classified into the low dose, such as 0.5[Mrad], 1[Mrad], 2[Mrad]. The effect of electron team irradiation is studied by investigating the electrical properties of dielectric liquid due to the difference of electron beam dose. To measure the physical properties of transformer oil, courier Transform-Infrared Spectroscopy is investigated. And the study far the electrical properties is made by measuring the volume resistivity of each specimen. By means of the result from this experiments, it is introduced that the movement of carrier to contribute to the volume resistivity on the electrical properties.

  • PDF

전자선 조사에 따른 변압기유의 전기적 특성 (Electrical Properties of Transformer Oils due to Electron Beam Irradiation)

  • 이용우;조돈찬;홍진웅
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권8호
    • /
    • pp.756-762
    • /
    • 1997
  • In this paper the change of electrical properties of transformer oil due to electron beam irradiation is investigated. The specimens are produced with a some different dose of 0.5[Mrad], 1[Mrad] and 2[Mard] except for original specimen. The physical properties of each specimen is analyzed by using the FT-IR spectrum. So it is confirmed that carbonyl groups are increased according to the increase of electron beam dose and also that the nitric compounds are disappeared. The magnitude of dielectric dissipation factor appears maximum value by the contribution of dipoles and ions in the low temperature low voltage region and it is stable due to the saturation of carriers in the high temperature high voltage region in the electric conduction characteristics. Volume resistivity is also measured one of original specimen is larger than irradiated specimen.

  • PDF

Antidiabetic Activity of Formular containing an Euonymus alata and Mori Foluim in Multiple Low Dose Streptozotocin-induced Rats

  • Chung, Sung-Hyun;Lee, Sung-Hyun;Kim, Hee-Ja
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.97.1-97.1
    • /
    • 2003
  • Antidiabetic activity of formular containing an Euonymus alata (EA) and Mori Foluim (MF) was investigated in oral glucose tolerance test (OGTT) and multiple low dose Streptozotocin (MLDSTZ)-induced rats. Optimum ratio between EA and MF was found to be 1:1 in OGTT, and two strengths (250 and 500 mg/kg for each medicinal plant) were coadministered with 20 mg/kg of STZ in 5 consecutive days. At 3rd week, water and food intakes were compared between groups and polydipsia and polyphagia shown in diabetic control were markedly improved in dose dependent manner. (omitted)

  • PDF

비인두암 환자에 대한 세기조절 방사선치료 시 이용되는 MVCT와 kV-CBCT의 수정체 흡수선량 평가 (Evaluation of the Lens Absorbed Dose of MVCT and kV-CBCT Use for IMRT to the Nasopharyngeal Cancer Patient)

  • 최재원;김철종;박수연;송기원
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.131-136
    • /
    • 2013
  • 목 적: 비인두암(Nasopharyngeal cancer) 환자를 세기조절 방사선치료(IMRT)시 영상유도 촬영(MVCT & kV-CBCT)에서의 수정체 흡수선량(absorbed dose)을 평가하고자 한다. 대상 및 방법: 인체모형팬텀(Anderson rando phantom, Alderson Reserch Laboratories Inc., USA)을 대상으로 전산화 단층촬영(lightspeed ultra 16, General Electric, USA)을 실시하였고 획득되어진 이미지를 비인두암 환자의 치료계획에 동일한 조건으로 토모세라피 치료계획장치(Tomotherapy, Inc, USA)와 선형가속기 치료계획장치(Pinnacle 8.0, philips Medicle System)로 동일하게 수립하였다. 열형광선량계(TLD100 Harshaw USA)를 수정체 위치에 위치시키고 토모세라피 MVCT를 세 가지 조건(fine, normal, coarse)에서 촬영, kV-CBCT를 두 가지 조건(low dose head, standard dose head)에서 각각 좌우 3번씩 반복 측정하였다. 결 과: 토모세라피와 선형가속기를 이용하여 실시한 MVCT와 kV-CBCT 촬영 시 수정체의 흡수선량을 측정한 결과 토모세라피 MVCT에서 coarse의 경우 RT 0.8257 cGy, LT 0.8137 cGy, normal의 경우 RT 1.089 cGy, LT 1.188 cGy, fine의 경우 RT 2.154 cGy, LT 2.082 cGy라는 결과를 얻을 수 있었다. 선형가속기 kV-CBCT에선 standard mode의 경우 RT 0.2875 cGy, LT 0.1676 cGy, Low-dose mode의 경우 RT 0.1648 cGy, LT 0.1212 cGy로 나타났다. MVCT와 kV-CBCT의 최대 차이는 약20배 이상인 것을 알 수 있다. 결 론: kV-CBCT가 MVCT을 통해 영상유도 이미지를 얻는 것보다 수정체 흡수선량만으로 고려하였을 때 세기조절 방사선 치료 시 환자가 치료 이외에 받는 선량을 줄일 수 있다고 판단된다. 또한 동일한 치료 장비라 하더라도 다양한 촬영조건에 따라 선량차이가 있다는 것을 알 수 있다.

  • PDF