• 제목/요약/키워드: Louver

검색결과 134건 처리시간 0.018초

도서관 열람공간의 방위 및 루버시스템에 따른 주광성능 평가 (An Evaluation of Daylight Performance in the Reading Room of a Library according to Different Azimuths and Louver Systems)

  • 박주현;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.45-51
    • /
    • 2006
  • Recently, various kinds of daylight system are recognized as an important and useful strategy in energy-efficient building designs. However, a large amount of direct sunlight can make many problems. Therefore, it is necessary to control daylighting through louver systems for high quality visual environment. The purpose of this study is to analyze daylighting performance in the reading room of a library according to different azimuths and louver systems. The results evaluated daylight performance based on the RADIANCE lighting software.

PIV 풍동실험을 통한 공장건물의 자연환기 향상 연구 (Improvement of Natural Ventilation in a Factory Building Using PIV Technique)

  • 강종훈;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2005
  • Vents at outer walls of a large factory building are very important for natural ventilation. But, if a full-open vent is used, rain comes through the vents. We tried to utilize the natural ventilation effectively using a louver. A 1/120 scale-down building model was placed inside an atmospheric boundary layer simulated in a wind tunnel test section. The effect of louver angle on the ventilation flow inside the factory building was investigated experimentally. Instantaneous velocity fields inside the building model were measured using a 2-frame PIV system with varying the louver angles ($\theta=20^{\circ},\;40^{\circ},\;60^{\circ}$). For the case of $\theta=60^{\circ}$, as the incoming flow into the factory building increases, the inside velocity distribution becomes uniformly.

  • PDF

자동차용 응축기의 휜 열전달 및 압력강하 특성 (Characteristics of Fin-Side Heat-Transfer and Pressure Drop in a Condenser for Automobile)

  • 곽경민;이홍열
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.152-158
    • /
    • 2004
  • An experimental study was performed to determine the fin-side heat transfer and pressure drop of a condenser for automobile. Five sample with different fin height and louver angle were tested, 9mm, 8mm, 7.5mm, 5.4mm and 4.5mm. Results are presented as plot of Colburn j-factor(or heat transfer coefficients) and friction factor(or pressure drop) against the Reynolds number(or inlet air velocity) based on louver pitch, in the range of 110 to 480. The results show that both heat transfer and pressure drop on the fin are mainly affected by the louver angle in a lower range of air velocity, but, by the fin height in a higher range of air velocity. The performance of 5.4mm fin is the highest, compared to other fin sample.

와류발생기의 충돌각과 루버각의 상호작용에 의한 열전달촉진 (Heat Transfer Enhancement by the Combined Effect of Louver Angle and Angle of Attack of Vertex Generator)

  • 박병규;정재동;이준식
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.477-484
    • /
    • 2002
  • A numerical investigation of the performance of the plate heat exchanger with rectangular winglet is conducted to examine the combined effect of vortex generator and louver fins. Velocity and temperature fields and spanwise averaged Nu and friction factor are presented. Enhancement of heat transfer and flow loss penalty is evident. A Parametric study of three factors (Re, angle of attack and louver angle) with levels of 5 (Re= 300, 500, 700, 900, 1100), 4($\alpha=15^{\circ}, 30^{\circ}, 45^{\circ}, 90^{\circ},$), and 4($\beta=0^{\circ}, 15^{\circ}, 30^{\circ}, 45^{\circ}$), respectively, indicates the performance defined by the ratio of heat transfer enhancement to flow loss penalty shows monotonic behavior for each parameter alone but the interactions between parameters is found to be considerable effect on the performance of heat exchanger and should be considered in design. The effect of stamping is also examined.

복합 전열 촉진 핀이 적용된 핀-관 열교환기의 성능에 대한 실험적 연구 (An Experimental Study on Air-Side Performance of Fin-and-Tube Heat Exchangers Having Compound Enhanced Fins)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4364-4374
    • /
    • 2015
  • 본 연구에서는 복합 전열 촉진 핀 열교환기의 열전달 및 압력손실에 대하여 실험적으로 검토하였다. 비교를 위하여 널리 사용되는 루버 핀 열교환기에 대한 실험도 수행하였다. 핀 피치(1.5mm~1.7mm)와 열수(1열~3열)를 변화시키며 열전달 및 압력손실에 미치는 영향을 검토하였다. 실험범위에서 핀 피치가 j와 f 인자에 미치는 영향은 크지 않았다. 열수가 증가하면 j 인자는 감소하고 f 인자는 열수와 무관하였다. 루버 핀의 j와 f 인자가 복합 전열 촉진 핀의 값들보다 크게 나타났다. 1열의 경우 평균 j 인자와 f 인자는 23%, 27% 크고, 2열에서는 11%, 8%, 3열에서는 10%, 9% 크게 나타났다. 하지만 동일 압력 손실 대비 전열 성능은 복합 전열 촉진 핀 열교환기가 1열에서 6.4%, 2열에서 11.1%, 3열에서 13.6% 크게 나타났다. 기존 루버 핀 상관식은 j 인자를 과대 예측하고 f 인자를 과소 예측하였다.

운전조건 변화에 따른 루버휜 열교환기 성능변화에 관한 실험적 연구 (An Experimental Study on the Performance of the Louver Fin Type Heat Exchanger by the Change of the Driving Condition)

  • 김정국;소산번;상원헌;김동휘;박병덕
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.440-445
    • /
    • 2008
  • The present study was investigated the effect of the driving condition on the performance of a louver fin and tube type heat exchanger under frosting condition. Heat transfer rate and pressure drop by frost were experimentally investigated. Effects of the wet blub temperature and the shape of a fin on heat transfer performances has been also investigated. The key parameters were fin type(louver and corrugate fin) and the wet blub temperature of air (0.5, 1.0, $1.5^{\circ}C$). The heat transfer performance of the louver fin and tube type heat exchanger was higher by 0.89% than the corrugate fin type. As the wet blub temperature of air were increased, the heat transfer rate, pressure drop and mass of frost of three test models(Type A, B, C) were increased. Especially, the maximum heat transfer rate and maximum pressure drop were shown for the louver fin and tube type heat exchanger. As a experimental result, the enhancement factor(EF) of louver fin and tube type heat exchanger was $0.2{\sim}0.4$ due to the high pressure drop.

  • PDF

공랭식 열교환핀이 부착된 열전모듈의 냉각 성능에 관한 연구 (Cooling Performance of Thermoelectric Module with Air-Cooled Heat Exchanger Fins)

  • 신재훈;한훈식;김윤호;김서영;현재민
    • 설비공학논문집
    • /
    • 제22권3호
    • /
    • pp.171-179
    • /
    • 2010
  • Thermal performance of louver fin and plate fin in a thermoelectric cooling system with a duct-flow type fan arrangement is analytically evaluated. The thermoelectric cooling system consists of a thermoelectric module and two heat exchanger fins. The analytic results show that the optimized louver fin has lower thermal resistance than plate fin. The COP and heat absorbed rate of the thermoelectric cooling system with optimized louver fins are 10.3% and 5.8% higher than optimized plate fins, respectively.

HRSG건물 온도제어를 위한 환기방안에 관한 수치적 연구 (Numerical Study on Ventilation Method for Temperature Control of HRSG Building)

  • 김철환;이종욱;최훈기;유근종
    • 한국산업보건학회지
    • /
    • 제19권3호
    • /
    • pp.240-249
    • /
    • 2009
  • HRSG(Heat Recovery Steam Generator) building is large enclosed structure included various heat sources. This building needs to appropriately keep internal air temperature for worker's safety and operability of control devices. In this study, ventilation analysis is performed to find proper ventilation method for temperature control. Ventilation analysis is applied to entire internal space of the building with standard $k-{\varepsilon}$ model and enhanced wall treatment because of large size of the structure. And the ventilation method is considered natural and forced convection with two louver structures which has damper or not. Louver structure affect directly air circulation in near HRSG and lower region of the building. Forced ventilation provides strong inertial force which cause upward airflow. From the analysis, it is found that design requirement for internal air temperature can be satisfied by forced ventilation method with louver structure without damper.

슬림형 루버 핀이 장착된 알루미늄 열교환기의 공기측 전열 성능에 대한 실험적 연구 (Experimental Study on the Airside Performance of Aluminum Heat Exchangers Having Slim Louver Fins)

  • 김내현;조홍기
    • 대한기계학회논문집B
    • /
    • 제41권9호
    • /
    • pp.587-595
    • /
    • 2017
  • 최근 들어 공조기가 슬림화 되고 따라서 열교환기의 깊이를 줄일 필요가 있다. 본 연구에서는 슬림형 알루미늄 열교환기에 적절한 루버 핀 형상을 도출하였다. 또한 도출된 루버 핀이 적용된 알루미늄 열교환기 시료를 제작하고 성능 시험을 수행하였다. 비교를 위하여 기존 열교환기에 대해서도 실험을 수행하였다. 도출된 형상의 핀 깊이($F_d$)는 10.0 mm, 루버 핏치($L_p$)는 0.9 mm, 루버 각(${\theta}$)은 $35^{\circ}$이다. 기존 시료에 비하여 신규 슬림 시료의 j 인자는 36%, f 인자는 2.3% 크게 나타났다. 따라서 열교환기 체적은 슬림 시료에서 26% 줄어들게 된다. 또한 동일 소비 동력에서의 전열량을 의미하는 $j/f^{1/3}$은 슬림 시료에서 55% 크다. 실험 데이터를 기존 상관식의 예측치와 비교하였다.

복합 전열 촉진 핀이 적용된 핀-관 열교환기의 습표면 성능에 대한 실험적 연구 (An Experimental Study on Air-Side Performance of Fin-and-Tube Heat Exchangers Having Compound Enhanced Fins Under Wet Condition)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.5778-5788
    • /
    • 2015
  • 본 연구에서는 복합 전열 촉진 핀 열교환기의 습표면 열전달 및 압력손실에 대하여 실험적으로 검토하였다. 비교를 위하여 널리 사용되는 루버 핀 열교환기에 대한 실험도 수행하였다. 핀 핏치(1.5mm~1.7mm)와 열수(1열~3열)를 변화시키며 열전달 및 압력손실에 미치는 영향을 검토하였다. 실험범위에서 핀 핏치가 j와 f 인자에 미치는 영향은 크지 않았다. 열수가 증가하면 j와 f 인자 모두 감소하였다. 복합 전열 핀 열교환기의 j와 f 인자가 루버 핀 열교환기의 값들보다 크게 나타났다. 1열의 경우 평균 j 인자와 f 인자는 11%, 43% 크고, 2열에서는 8%, 50%, 3열에서는 17%, 53% 크게 나타났다. 동일 압력 손실 대비 전열 성능은 복합 전열 촉진 핀 열교환기가 1열에서 2.0%, 2열에서 3.1%, 3열에서 8.4% 크게 나타났다. 실험 자료를 기존 루버 핀 상관식과 비교하였다.