• 제목/요약/키워드: Losses

검색결과 5,298건 처리시간 0.033초

고온초전도동기모터의 교류손실에 따른 ?치 해석에 관한 연구 (A Study on the Quench characteristics Analysis considering Ac-Losses of High-Tc Superconducting Synchronous Motor)

  • 윤용수;송명곤;문창욱;홍계원;이상진;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.93-96
    • /
    • 1999
  • This paper deals with the quench characteristic analysis in high-Tc superconducting synchronous motor of five to six hundred watts capacity. First, the magnetic field distribution and ac losses of high-Tc superconducting motor with the additive flux damper circuit was derived and computer simulation was performed with the equivalent model using FEM. The simulation results show that the quench state lasts for about 0.3 seconds.

  • PDF

Development of Inspect Algorithm for Pallets Using Vision System

  • Lee, Man-Hyung;Hong, Suh-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.101.6-101
    • /
    • 2001
  • This paper deals with inspect algorithm using visual system. One of the major problems that arise during polymer production is the estimation of the noise of the product(bad pallets). An erroneous output can cause a lot of losses (production and financial losses). Therefore new methods for real-time inspection of the noise are demanded. For this reason, we have presented a development of vision system algorithm for the defect inspection of PE pallets. First of all, in order to detect the edge of object, the differential filter is used. And we apply to the labeling algorithm for feature extraction. This algorithm is designed for the defect inspection of pallets ...

  • PDF

복굴절, 입력 편광상태 및 광손실이 광섬유간섭계의 visibility에 미치는 영향 (The visibility variation of the mach-zehnder optical fiber interferometerdue to birefringences, input states of polarization and optical losses)

  • 강현서;이영택;이경식
    • 전자공학회논문지A
    • /
    • 제33A권2호
    • /
    • pp.140-147
    • /
    • 1996
  • The output of the mach-zehnder optical fiber interferometer varies with birefringences existing in the figer arms. New equations experessing for the visibility of the mach-zehnder interferometer were derived in terms of a number of parameters related to the birefringences, the input SOP and the optical losses. Based on the equations the visibility of the interferometer was simulated in different cases. Some maximum visibility conditons were also presented.

  • PDF

고온초전도 적층선재에서의 층간 거리에 따른 자화손실 (Magnetization Losses of the HTS Stacked Tapes at Various Gap between Tapes)

  • 최명섭;박명진;차귀수;이지광
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.250-253
    • /
    • 2003
  • Rise of the current level at power applications, such as, transformer, motor and power cable, need for using stacked HTS tapes. In this paper, we measured losses of the stacked HTS tapes. Three different types of the stacks which were made of 2 tapes, 3 tapes and 4 tapes, were tested Perpendicular magnetic field was applied to the HTS stacks as the external magnetic field. Effects of the gap between HTS tapes were examined.

  • PDF

토양으로부터 휘발되는 암모니아와 이산화질소의 소실에 대한 식피형의 영향에 대하여 (Influence of Vegetaton Type on the Intensity of Ammonia and Nitrogen Dioxide Liberation from Soil)

  • 김천민
    • Journal of Plant Biology
    • /
    • 제14권3호
    • /
    • pp.43-46
    • /
    • 1971
  • Losses of nitrogenin the gaseous form were determined with closed systems in the filed under different vegetation types. Ammonia volatilization was greatest from the pine stand, and least from the sod stand, and was greatly reduced in all three sites in the rainy season due to the low temperature. There were only insignificant differences in the nitrogen dioxide volatilization from the soil of the three vegetation types. Losses of ammonia and nitrogen dioxide at various soil depth also showed little variation. Evidently the microbial activity responsible for the $NO_2$ loss was relatively unaffected by the changes in temperature and soil moisture content during the investigation.

  • PDF

홉필드 신경회로망의 전력경제급전에의 응용에 관한 연구 (A Study on the Application of Hopfield Neural Network to Economic Load Dispatch)

  • 엄일규;김유신;박준호
    • 대한전기학회논문지
    • /
    • 제41권1호
    • /
    • pp.1-8
    • /
    • 1992
  • Hopfield neural network has been applied to the problem of economic load dispatch(ELD) of electric power. The optimum values of neuron potentials are represented in terms of large numbers. The differential synchronous transition mode is used in this simulation. Through case studies, we have shown the possibility of the application of neural network to ELD. In case of including the transmission losses, the proposed method has an advantage that the problem can be solved simply with one neural network, without calculating incremental fuel costs and incremental losses required by traditional method.

전기적 측정법을 사용한 팬케이크 코일에서의 교류손실 측정 (AC Losses of the HTS Pancake Coil by Using Electric Method)

  • 이승욱;임형우;최명섭;이희준;차귀수;이지광
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.37-40
    • /
    • 2003
  • This paper presents calculated and measured AC losses of the HTS pancake coil. Magnetic field in the HTS coil under operating conditions was calculated by FEM. Results of measured ac loss in 4-stacked short sample were used in the AC loss calculation. Various methods, such as, electric method, calorimetric method, wattmeter method, were used to measure the AC loss.

  • PDF

직류전기철도시스템에서의 누설전류에 의한 전식방지에 대한 연구 (A study of Protection for electrical corrosion by stray current in DC railway system)

  • 이재영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.748-753
    • /
    • 2005
  • The stray current(leakage current) in DC railway system like as Metro Subway and LRT system happens electrical corrosion on theses superstructure facilities and also underground facilities that causes the public property losses. we must study and establish on the theoretical concept and concrete phenomena for electrical corrosion, In the construction period we intend to review and find out a lot of solution to minimize theses losses. we must investigate, measure and analysis natural atmosphere of these facilities locations to present a maintenance management guide for the upcoming operation stage.

  • PDF

Two-transistor 포워드 컨버터에서 소프트 스위칭 기법의 손실 계산

  • Kim Marn-Go
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.698-701
    • /
    • 2001
  • Loss analyses of two soft switching techniques for two-transistor forward converters are presented. The sums of snubber conduction and capacitive turn-on losses for two transistors are calculated to compare the losses of two techniques. While the conventional soft switching technique shows the loss difference between two transistors, proposed soft switching technique shows equal as well as lower loss in two transistors.

  • PDF

전자장해석을 이용한 풍력발전용 전력 케이블의 전자기적 고찰 (Finite Element Analysis of Power Cables for Wind Turbine Application)

  • 김지현;조성호;이인우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.257-260
    • /
    • 2006
  • This paper presents electromagnetic finite element analysis of power cables for wind turbine application. Eddy current losses are calculated due to high currents along metallic part, and dielectric strength on power cables is investigated for case study, which suggests the optimal cabling configuration for wind turbine construction.

  • PDF