• 제목/요약/키워드: Loss of area

검색결과 2,744건 처리시간 0.035초

산림의 토사유출 방지기능에 관한 연구 (Study on Quantifying Erosion Control Function of Forest)

  • 윤호중;이창우;정용호
    • 한국환경복원기술학회지
    • /
    • 제10권1호
    • /
    • pp.36-43
    • /
    • 2007
  • This study was carried out to know how erosion control function of forests varies as forests develop in watersheds. The erosion control function among the forest welfare functions can be estimated by comparing sediment yield in stocked with non-stocked area. Sediment yield of reservoirs in stocked area were collected from farmland improvement associations. The sediment yields in non-stocked area were using USLE (Universal Soil Loss Equation) in the same reservoirs. Forests' erosion control function estimated by differences of the sediment yield between stocked and non-stocked area was static model because of no consideration on forest aging. Dynamic model was developed to consider a forest stand age. The model comprises the relationship between average forest age in watershed and sediment yield. The amount of sediment yield was different depending mother rocks. It decreased exponentially according to the forest's grow up. In case of igneous rock, the volume of sediment yield $Y_{ig}=1.4431e\;^{0.023x}$(x=average forest age), metamorphic rock $Y_{me}=4.7115e\;^{0.0694x}$, and sedimentary rock $Y_{se}=1.2808e\;^{0.028x}$.

증속 기어 압축기용 스러스트 칼라의 윤활 성능 해석 (Performance Analysis of Oil-lubricated Thrust Collars in Integrally Geared Compressors)

  • 이동현;김병옥;선경호
    • Tribology and Lubricants
    • /
    • 제34권5호
    • /
    • pp.169-174
    • /
    • 2018
  • A multi-stage compressor (MSC) is comprised of several impellers installed in the pinion gear shaft driven by a main bull gear. In the pinion shaft, a thrust collar (TC) is installed to support the thrust load. The TC makes the lubrication system simpler in the MSC; therefore, it is widely used in similar kinds of machinery. Typically, TCs are installed on both sides of the bull gear and pressure is developed in the lubricated area by creating a taper angle on the TC and bull gear surface. In the current study, we developed a numerical analysis model to evaluate the performance of the TC considering its design parameters. We sloved the Reynolds equation using the finite element method and applied the half Sommerfeld condition to consider cavitation. Based on the pressure calculated in the lubricated area, we calculated the power loss and minimum film thickness. In addition, we calculated stiffness and damping using perturbation method. We performed parametric studies using the developed model. The results of the analysis show that the maximum pressure presents in the center area of the TC and it increases with the taper angle. The area over which pressure is developed decreases with the taper angle. The results also show that there is an optimum taper angle providing minimum power loss and maximum film thickness. Additionally, the stiffness and damping decrease with the taper angle. As the applied load increases, the power loss increases and the minimum film thickness decreases. However, the stiffness and damping increase with the applied load.

상악골 부분 절제술을 받은 환자에서 구개 폐쇄 장치를 이용한 보철치료: 증례보고 (Prosthetic Treatment with Palatal Obturator for the Patient who had Hemimaxillectomy: Case Report)

  • 최수정;조광헌;이규복
    • 구강회복응용과학지
    • /
    • 제27권3호
    • /
    • pp.337-342
    • /
    • 2011
  • 악안면 부위의 선천적 결손이나 외상성 손실, 종양의 외과적 절제 등에 의한 악골의 결손은 환자에게 저작 장애, 연하 장애 등의 기능적 문제와 발음장애 및 심미적 장애를 초래하게 된다. 이러한 장애를 줄여주고 손상된 조직과 기능을 회복시켜주기 위해 많은 경우 보철적인 수복을 필요로 하게 된다. 상악골에 결손부가 생긴 경우 음식물과 액체가 비강으로 새어나가고 이 결손부로 공기가 누출되어 과비음이 발생한다. 이런 경우에 구개 폐쇄 장치가 사용되는데, 이 장치는 상악의 결손부를 채우고 구강과 상악동 또는 비강과의 개통부를 차단하여 심미성을 증진시키고 기능을 회복시킨다. 본 증례의 환자는 우측 상악동에 편평상피세포 암종이 발생하여 상악골 부분 절제술을 시행한 환자로 구개 폐쇄 장치를 제작하여 장착한 후, 발음과 연하 등의 기본적 기능이 회복되었고 안모의 심미성이 증가하였다.

우리나라 농업기상재해의 공간 분포 및 지역 특성 분석 (Spatial Distribution and Regional Characteristics of Meteorological Damages to Agricultural Farms in Korea)

  • 송인홍;송정헌;김상민;장민원;강문성
    • 한국농공학회논문집
    • /
    • 제54권6호
    • /
    • pp.45-52
    • /
    • 2012
  • Along with global warming, ever intensifying weather events have increased damages to agricultural farms and facilities. The objective of this study was to investigate the spatial distribution and regional characteristics of agricultural damages by extreme weather events. Agricultural disaster statistics provided by the National Emergency Management Agency were summed over for a 13-year period from 1998 to 2010 and used for the spatial analysis. Two indices of damage area ration and property damage per unit area were introduced to quantify regional agricultural damages. As the results, farm inundation accounted for the largest area primarily damaged by typhoons with heavy rainfalls. Most property damages to farm lands originated from farm erosion in the alpine regions by localized guerrilla rains. The two major causes of damages to greenhouse and livestock facilities were typhoon with strong wind and winter blizzards. Gangwon was the province of the largest property loss mostly from farm land erosion losses, followed by Gyeongnam, Jeonnam, and Chungnam where losses to greenhouse and livestock facilities were relatively greater. Property loss per unit area was also the greatest for the Gangwon province (4.91 M\/ha), followed by Gyongnam and Chungnam of 2.20 and 1.50 M\/ha, respectively. Unit loss for greenhouse and livestock facilities was 13.3 M\/ha, approximately 13 times greater than that for farm land (1.06 M\/ha). The study findings indicated the importance of reducing highland farm erosion and reinforcing farming facilities structures for agricultural disaster management.

소형 잔향실의 확산 음장 보정 계수 측정 연구 (The Study on Correction Factor of a Small Scale Reverberation Chamber to Estimate Transmission Loss)

  • 김태민;김다래;김정태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.960-965
    • /
    • 2014
  • Transmission loss of specimen is calculated by measuring energy of incident and transmission and using reverberant room of large size. But normal measurement of transmission loss has trouble because it is actually demanded that large area and specimen of certain size is satisfied with condition of diffused sound field. Especially, in case of mechanical component, interested frequency band is mid-frequency band between 500 ~ 2k Hz, and it is used to be available to minimize a reverberation chamber under conditions satisfying acoustic one because production of specimen for transmission loss measurement has limit. But, as in semi-reverberation room, it is difficult to satisfy condition of diffuse sound field and modification factor is applied to complement that. Correction factor when measuring transmission loss using semi-reverberation chamber is required accuracy because it works as main factor determining reliability of reuslts on transmission loss. In this study, it is analyzed that an effect on correction factor based on varying materials and sizes of specimens in order to deduction of it. Also It is confirmed that applied by elicited correction factor with actual railway vehicle's floor has reliability.

  • PDF

Application of Remotely Sensed Data and Geographic Information System in Watershed Management Planning in Imha, Korea

  • CHAE Hyo-Sok;LEE Geun-Sang;KIM Tae-Joon;KOH Deuk-Koo
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.361-364
    • /
    • 2005
  • The use of remotely sensed data and geographic information system (GIS) to develop conservation-oriented watershed management strategies on Imha Dam, Korea, is presented. The change of land use for study area was analyzed using multi-temporal Landsat imagery. A soil loss model was executed within a GIS environment to evaluate watershed management strategies in terms of soil loss. In general, remotely sensed data provide efficient means of generating the input data required for the soil loss model. Also, GIS allowed for easy assessment of the relative erosion hazard over the watershed under the different land use change options. The soil loss model predicted substantial declines in soil loss under conservation-oriented land management compared to current land management for Imha Dam. The results of this study indicate that soil loss potential (5,782,829 ton/yr) on Imha Dam in 2003 is approximately 1.27 times higher than that (4,557,151 ton/yr) in 1989. This study represents the first attempt in the application of GIS technology to watershed conservation planning for Imha Dam. The procedures developed will contribute to the evolution of a decision support system to guide the land planning and dam management in Imha Dam.

  • PDF

고속도로 절토 비탈면과 인접 자연식생지의 토양 환경 비교 분석 (A Study on Soil Environment in Highway Cutting Slope and Adjacent Natural Vegetation Area)

  • 박관수;전기성;송호경;김남춘;최재용
    • 한국환경복원기술학회지
    • /
    • 제9권2호
    • /
    • pp.16-22
    • /
    • 2006
  • This study was carried out to estimate the physical and chemical soil characteristics in highway cutting slope areas. The soil was sampled in cutting area and natural vegetation area that was located in the upper areas of the highway cutting slope. The average total soil depth, bulk density, and soil hardness were bad in the highway cutting slope sites. The sandy loam was the most soil texture in the study area. The concentration of soil organic matter and nitrogen were very low in all highway cutting areas. The concentration of exchangeable cations was similar between the highway cutting slope and the natural vegetation sites in each highway. The soil pH was higher in highway cutting slope areas than in natural vegetation sites. In conclusion, chemical and physical properties of soil were bad in the cutting slope than in the natural vegetation area because of the loss of soil by cutting of slope area and less organic matter input by less vegetation in the highway cutting slope area. We should employ possible method to reduce the loss of soil, and compost and fertilization treatment could help to increase soil nutrient content in the cutting slope area.

분포형 토양침식지도를 이용한 한강상류지역 토양유실 위험성 평가 (Soil Erosion Risk Assessment in the Upper Han River Basis Using Spatial Soil Erosion Map)

  • 박찬원;손연규;장용선;홍석영;현병근;송관철;하상건;문용희
    • 한국토양비료학회지
    • /
    • 제43권6호
    • /
    • pp.828-836
    • /
    • 2010
  • 본 연구에서는 1:25,000 정밀토양도 등 가용한 공간자료를 이용하여 작성된 토양유실도를 이용하여 한강 상류지역 10개 중권역 108 소유역에 대하여 토양유실량 평가하고 토지이용별 토양유실 위험지역을 분석하였다. 대상유역 총 토양유실량은 895만 Mg $yr^{-1}$으로 예측되었으며, 면적당 평균 토양유실량은 6.1 Mg $ha^{-1}yr^{-1}$ 이었다. 중소유역 단위로 살펴보면 남한강지역이 북한강 지역의 유실량 뿐만 아니라 면적당 유실량이 더 많았다. 이는 북한강 권역의 경우 화강암 및 화강편마암이 주요모재인 반면에 남한강 권역의 경우 토양모재가 퇴적암지대를 많이 포함있어 토양침식성 인자 (K factor)와 경사인자 (LS factor)가 상대적으로 높고, 남한강 지역의 경우 농경지 토양이 상대적으로 많이 분포하고 있기 때문으로 판단된다. 대상유역의 토지이용별 연평균 토양유실량을 분석한 결과 산림/초지 > 밭 ${\gg}$ 도심/대지 ${\gg}$ 논 > 과수의 순로분석 대상유역 중 10.7%를 차지하고 있는 농경지에서 유실되는 토양의 추정량은 41.3%이였으며, 이중 6.2% 면적을 차지하는 밭이 40.6%으로 44.2%의 산림/초지와 비슷한 수준이었다. 한강상류지역 토양유실 위험성 평가시 분포형 토양침식지도와 항공사진을 비교한 결과 토양유실에 대한 공간인 정보를 확실하게 보여주고 있으며, 토양침식위험성은 남한강권역의 남한강 상류 (1001), 평창강 (1002), 충주댐 (1003) 권역에서 각각 토양침식위험성이 "보통" 이상으로 높은 지역이 각각 8.7%, 7.9%, 7.8%로 평균인 5.9%보다 높았으며, 이에 대한 보전방안이 강구될 필요가 있고 판단된다.

부산물 석고를 이용한 산불피해 지역 토양유실 방지 (Effect of By-product Gypsum on Soil Erosion at Burned Forest Land)

  • 김계훈;정창욱
    • 한국환경복원기술학회지
    • /
    • 제3권4호
    • /
    • pp.52-59
    • /
    • 2000
  • This study was carried out to find out effect of by-product gypsum on reducing soil erosion at the sloping burned area at Sampo-ri, Gosung-gun in Kangwon-province during the period between June 28 and Sept. 30, 2000. Four experimental plots ($1.2m{\times}10m$) were prepared at the study area with slopes $15^{\circ}{\sim}18^{\circ}$ where forest fire took place twice during last 4 years. Phosphogypsum (PG) was applied to the soils of the 4 plots at the rates of 0 (control), 5, 7.5, and 10 ton/ha, respectively. Amount of rainfall, runoff, and soil loss were measured 7 times during the study. In the beginning, the amounts of runoff and soil loss from the PG treated plots were not different from those from the control plot due to steepness of the plots. However, the difference between the amount of runoff and soil loss from the PG treated plots and those from the control became apparent over time. The effect of PG treatment lasted until at least 870 mm of rainfall. Compared to the cumulative runoff from the control plot, the cumulative runoff from the plots treated with 5, 7.5, and 10 ton/ha PG decreased 7%, 31 %, and 35%, respectively. The cumulative soil loss from the plots treated with 5, 7.5, and 10 ton/ha PG decreased 44%, 53%, and 77% compared to that from the control plot. Strong acidity of PG (pH 2.0~2.5) did not affect the acidity of the soil and runoff.

  • PDF

광분배를 위한 Y-branch 제작과 광파이버와의 결합특성에 관한 연구 (A study on the fabrication of Y-branch for optical power distribution and its coupling properties with optical fiber)

  • 김상덕;박수봉;윤중현;이재규;김종빈
    • 한국통신학회논문지
    • /
    • 제21권12호
    • /
    • pp.3277-3285
    • /
    • 1996
  • In this paper, w designed an opical power distribution device for application to an optical switching and an optical subscriber loop. We fabricated PSG thin film by LPCVD. Based on the measured index of fabricted thin film, rib-type waveguide was transformed to two-dimension by the effective index method and we simulated dispersion property to find asingle-mode condition. We found that the optimum design parameters of rib-type waveguide are:cladding layer of 3.mu.m, core layer of 3.mu.m, buffer layer of 10.mu.m, and core width of 4.mu.m. Each side of the guiding region was etched down to 4.mu.m to shape the core. We used these optimum parameters of the rib-type waveguide with branching angle of 0.5.deg. and simulted the Y-branch waveguide by the BPM simulation. Numerical loss in branching area was claculated to be 0.1581dB and equal to the total loss of the Y-branch. The loss of the fabricated Y-branch waveguide on PSG film ws 1.6dB at .lambda.=1.3.mu.m before annealing but was 1.2dB after annealing at 1000.deg. C for 10 minutes. Consequently, the loss of branching area from 3000.mu.m to 6000.mu.m in the z-direction was 0.8dB, and single-mode propagation was confirmed by measuring the near field pattern. For coupling the fabricated Y-branch waveguide with an optical fiber, we fabricated V-groove which was used as the upholder of optical fiber. An etching angle was 54.deg. and the width and depth of guiding groove was 150.mu.m, 70.mu.m, respectively. The optical fiber is inserted onto V-groove. Both the Y-branch and V-groove were connected through the index matching oil. Coupling loss after connecting Y-branch and the optical fiber on V-groove was 0.34dB and that after injecting index mateching oil was 0.14dB.

  • PDF