• Title/Summary/Keyword: Loss of Field

Search Result 2,332, Processing Time 0.027 seconds

A Study on the Accident Analysis of Architectural Work (건축건설공사의 재해분석에 관한 연구)

  • Kim, Jeongmin;Lee, Jong-Bin;Chang, Seong Rok
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.96-101
    • /
    • 2016
  • Previous literature has been investigated various aspects of accident occurrence and prevention in construction field. However, those studied were limited in that they only focused on the death accident without considering the loss time accident. Based on this, the goal of current study was to investigate the nature of the loss time accident, and compare the results with the death accident. Results showed that 1) the occurrence rate of death accident was significantly higher in the form work, temporary work, and steel frame work; 2) the temporary work showed significantly higher occurrence rate of the loss time accident and the death accident as compared to others; 3) ratio of the loss time accident to the death accident in domestic construction field was 50:1; 4) fall accident showed biggest occurrence rate in both the loss time accident and the death accident; and 5) more that 80% of workers in both the loss time accident and the death accident was between 41 and 65 years old.

The Magnetization Losses Characteristics of Multi-stacked and Variable Angle of External Magnet Field in YBCO CC and BSCCO tape (YBCO Coated Conducor와 BSCCO tape의 적층 및 외부자장의 각도에 따른 자화손실 특성)

  • Lim, Hyoung-Woo;Lee, Hee-Joon;Cha, Guee-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.34-38
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angle of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. The magnetization losses of YBCO CC are larger than those of BSCCO tapes when the external magnetic field is increased.

Eddy current loss calculation of flux shield in the large turbo generator using axi-periodic analysis (Axi-periodic Analysis를 이용한 대형 터보 발전기 단부 Flux Shield의 Eddy Current Loss 산정)

  • Kwon, Soon-O;Lee, Jung-Jong;Hong, Jung-Pyo;Nam, Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.987-989
    • /
    • 2005
  • Axi-periodic analysis using magnetic vector potential is formulated in time harmonic field and applied to the field analysis for the end region of large turbo generator in this paper. By using axi-periodic analysis, the effect of flux shield, one of the structure placed in the end region of large turbo generator to prevent stator end from thermal damage, is studied, and eddy current loss in the flux shield is estimated for operation conditions. 3D FEA is used for the verification of presented analysis method. Because 3D flux distribution can be calculated with 2D modeling, magnetic field showing 3D distribution can be effectively calculated by axi-periodic analysis comparing with 3D FEA.

  • PDF

Ac Loss Characteristics under Critical Current Degradation of HTS Tapes (고온 초전도체의 임계전류 저하에 따른 교류 손실 특성)

  • Kim, Hae-Joon;Kim, Jae-Ho;Sim, Ki-Deok;Cho, Jeon-Wook;Kwag, Dong-Soon;Kim, Hae-Jong;Seong, Ki-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.286-287
    • /
    • 2005
  • Critical current(Ic) degradation of HTS tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the Ie degradation affects the AC loss of the wire. We measured the Ie degradation and AC loss under tension and bending of Bi-2223 tapes processed by "Powder-in-Tube" technique at 17K with self-field. And we have studied the frequency dependence of self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between Ic degradation and AC loss are presented.

  • PDF

AC loss Characteristics under Critical Current Degradation of HTS Tapes (고온 초전도 tape의 임계전류 저하에 따른 교류손실 특성)

  • Kim H. J.;Cho J. W.;Kim J. H.;Sim K. D.;Kwag D. S.;Bae J. H.;Kim H. J.;Seong K. S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.29-33
    • /
    • 2005
  • Critical current$(I_c)$ degradation of High $T_c$ Superconducting(HTS) tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the $I_c$ degradation affects the AC loss of the wire. We measured the $I_c$ degradation and AC loss under tension and bending of Bi-2223 tapes made by 'Powder-in-Tube' technique at 77K with self-field. Also, we have studied the frequency characteristics on self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between $I_c$ degradation and AC loss are presented.

Round-robin Test on AC Losses in a Technical High-Tc Superconducting Tape (실용고온초전도테이프의 교류손실에 대한 Round-robin테스트)

  • 류경우;최병주;황시돌
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.437-443
    • /
    • 2004
  • In this work the AC loss measurement setup based on an iron core background magnet, not used in a conventional one, has been successfully developed. To prove its validity, a round-robin test for the same Bi-2223 tape sample among three institutes has been done. The results show that the self-field and magnetization losses from the developed setup well agree with the losses measured at two other institutes of Korea Basic Science Institute and Yokohama National University. The measured magnetization losses for parallel or perpendicular fields can be well predicted from the slab model or the strip model for a filamentary region. However the magnetization losses for longitudinal fields can be rather predicted by the slab model for a decoupled filament. The self-field losses are well explained by the Norris ellipse model.

Development of a Rapeseed Reaping Equipment Attachable to a Conventional Combine (Ill) - Analysis of Principal Factor for Loss Reduction of Rapeseed Mechanical Harvesting - (보통형 콤바인 부착용 유채 예취장치 개발 (III) - 유채 기계 수확 손실 절감을 위한 요인 구명 -)

  • Lee, C.K.;Choi, Y.;Jun, H.J.;Lee, S.K.;Moon, S.D.;Kim, S.S.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.2
    • /
    • pp.114-119
    • /
    • 2009
  • Field test was conducted to investigate primary factors reducing rapeseed harvesting using a reciprocating cutter-bar of combine. The results showed that the correlation between crop moisture content and yield loss had a U-type, which indicated that the yield reduction increased at too high and too low crop moisture contents. The proper ranges of crop moisture contents were 27${\sim}$35%, 21${\sim}$56%, and 62${\sim}$73% in case of grain, pod and stem, respectively. Crop moisture content was negatively correlated with header loss, but positively correlated with threshing loss. In contrary, stem moisture content showed positive correlations with total loss, threshing loss and separation loss. Working speed was positively correlated with header loss. Total flow rate, pod flow rate and stem flow rate were highly correlated with threshing loss and separation loss. However, grain flow rate did not show any correlation with total loss. According to the principal component analysis, two principal components were derived as components with eigenvalues greater than 1.0. The contribution rates of the first and the second components were 52.7% and 38.9%, which accounted for 91.6% of total variance. As a contributive factor influencing total loss of rapeseed mechanical harvesting, a crop moisture content factor was greater than a crop flow rate factor. The stepwise multiple regression analysis for total loss was conducted using crop moisture content factor, crop flow rate factor and coefficient. However, the model did not show any correlation among independent and dependent factors ($R^2$=0.060).

A Case of Combined Korean Medicine Treatment for Homonymous Hemianopia and Loss of Visual Acuity after hemorrhagic Stroke (동측 반맹 및 시력저하를 호소하는 후두엽 및 측두엽 뇌출혈 환자 한의복합치료 1례)

  • Si Yun Sung;Dabin Lee;Youngseon Lee;Ki-Ho Cho;Sang-Kwan Moon;Woo-Sang Jung;Seungwon Kwon;Han-Gyul Lee
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.25-40
    • /
    • 2023
  • Background: Although not clarified, the overall prevalence of visual field loss after stroke was estimated at 52% of stroke survivors and for visual acuity loss, at 70% of them. Among visual field loss patients after stroke, homonymous hemianopia is the most common symptom. Visual defect degrades the quality of life by disrupting independent life and affecting the survival of the patients, but highly-evidenced treatment has not been found until now. ■Case report A 51-year-old female with left-side homonymous hemianopia and central vision loss by a right occipital-temporal hemorrhage was treated with Hyeolbuchukeo-tang, Ikgibohyeol-tang, acupuncture, electroacupuncture, and moxibustion. We used a confrontation visual field exam, automated perimetry and visual analog scale, and visual acuity test to observe changes in the patient's symptoms and evaluate the efficacy of the treatment. After 61 days of such interventions, the patient's subjective discomfort lessened, followed by positive changes in the scales of tests mentioned above. ■Conclusion This case suggests that combined Korean medicine treatment might be an effective tool for treating post-stroke homonymous hemianopia and central vision loss. More studies should be conducted to support the effectiveness of the treatment.

  • PDF

Auditory Recognition of Digit-in-Noise under Unaided and Aided Conditions in Moderate and Severe Sensorineural Hearing Loss

  • Aghasoleimani, Mina;Jalilvand, Hamid;Mahdavi, Mohammad Ebrahim;Ahmadi, Roghayeh
    • Journal of Audiology & Otology
    • /
    • v.25 no.2
    • /
    • pp.72-79
    • /
    • 2021
  • Background and Objectives: The speech-in-noise test is typically performed using an audiometer. The results of the digit-in-noise recognition (DIN) test may be influenced by the flat frequency response of free-field audiometry and frequency of the hearing aid fit based on fitting rationale. This study aims to investigate the DIN test in unaided and aided conditions. Subjects and Methods: Thirty four adults with moderate and severe sensorineural hearing loss (SNHL) participated in the study. The signal-to-noise ratio (SNR) for 50% of the DIN test was obtained in the following two conditions: 1) the unaided condition, performed using an audiometer in a free field; and 2) aided condition, performed using a hearing aid with an unvented individual earmold that was fitted based on NAL-NL2. Results: There was a statistically significant elevation in the mean SNR for the severe SNHL group in both test conditions when compared with that of the moderate SNHL group. In both groups, the SNR for the aided condition was significantly lower than that of the unaided condition. Conclusions: Speech recognition in hearing-impaired patients can be realized by fitting hearing aids based on evidence-based fitting rationale rather than by measuring it using free-field audiometry measurement that is utilized in a routine clinic setup.

Comparison of Magnetization Losses in BSCCO Tape and YBCO CC at Arbitrary Direction of External Magnetic Field (BSCCO Tape 선재와 YBCO CC의 외부자장 각도에 따른 자화손실 특성비교)

  • Lee Ji-Kwang;Lim Hyung-Woo;Park Myung-Jin;Cha Gueesoo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.586-591
    • /
    • 2005
  • Magnetization loss of high temperature superconductoring BSCCO tape and YBCO coated conductor(YBCO CC) is most important issue in the development of superconducting power devices. In this paper, the measured results of magnetization losses in BSCCO tape and YBCO CC are presented and compared with each other. Measurements of magnetization losses are performed under various angles of external magnetic field to consider the anisotropic characteristics of YBCO CC. Also, we present the compared results of magnetization losses measured at arbitrary directional magnetic fields and analyzed with perpendicular magnetic field components of those. The results show that magnetization loss of YBCO CC agree well with the analyzed value by it's perpendicular magnetic field component, but BSCCO tape is not.