• 제목/요약/키워드: Loss distribution

검색결과 2,124건 처리시간 0.028초

전류분포가 3본-도체의 임계전류/교류손실 특성에 미치는 영향 (Influence of Current Distributions on Critical Current and AC Loss Characteristics in a 3-conductor)

  • 류경우;최병주
    • 한국전기전자재료학회논문지
    • /
    • 제16권5호
    • /
    • pp.418-423
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$\sub$c/ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The critical current and AC loss characteristics in the conductor have experimentally investigated. The results show that for uniform current distributions the conductor's critical current is proportional to the critical current of the Bi-2223 tape to which a voltage lead is attached. However it depends on the current non-uniformity parameter in the conductor rather than the tape's critical currents for nonuniform current distributions. The loss tests indicate that the AC loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.

다구찌 품질손실개념에 의한 다특성치 품질손실함수 도출의 분석적 접근방법 (An Analytical Approach to Derive the Quality Loss Function with Multi-characteristics by Taguchi's Quality Loss Concept)

  • 배후석;임채관
    • 품질경영학회지
    • /
    • 제48권4호
    • /
    • pp.535-552
    • /
    • 2020
  • Purpose: The main theme of this study is to derive a specific quality loss function with multiple characteristics according to the same analytical structure as the single characteristic quality loss function of Taguchi. In other words, it presents an analytical framework for measuring quality costs that can be controlled in practice. Methods: This study followed the analytical methodology through geometric, linear algebraic, and statistical approaches Results: The function suggested by this study is as follows; $$L(x_1,x_2,{\cdots},x_t)={\sum\limits_{i=1}^{t}}k_i\{x_i+{\sum\limits_{j=1}^{t}}\({\rho}_{ij}{\frac{d_i}{d_j}}\)x_j\}x_i$$ Conclusion: This paper derived the quality loss function with multiple quality characteristics to expand the usefulness of the Taguchi quality loss function. The function derived in this paper would be more meaningful to estimate quality costs under the practical situation and general structure with multiple quality characteristics than the function by linear algebraic approach in response surface analysis.

One-step deep learning-based method for pixel-level detection of fine cracks in steel girder images

  • Li, Zhihang;Huang, Mengqi;Ji, Pengxuan;Zhu, Huamei;Zhang, Qianbing
    • Smart Structures and Systems
    • /
    • 제29권1호
    • /
    • pp.153-166
    • /
    • 2022
  • Identifying fine cracks in steel bridge facilities is a challenging task of structural health monitoring (SHM). This study proposed an end-to-end crack image segmentation framework based on a one-step Convolutional Neural Network (CNN) for pixel-level object recognition with high accuracy. To particularly address the challenges arising from small object detection in complex background, efforts were made in loss function selection aiming at sample imbalance and module modification in order to improve the generalization ability on complicated images. Specifically, loss functions were compared among alternatives including the Binary Cross Entropy (BCE), Focal, Tversky and Dice loss, with the last three specialized for biased sample distribution. Structural modifications with dilated convolution, Spatial Pyramid Pooling (SPP) and Feature Pyramid Network (FPN) were also performed to form a new backbone termed CrackDet. Models of various loss functions and feature extraction modules were trained on crack images and tested on full-scale images collected on steel box girders. The CNN model incorporated the classic U-Net as its backbone, and Dice loss as its loss function achieved the highest mean Intersection-over-Union (mIoU) of 0.7571 on full-scale pictures. In contrast, the best performance on cropped crack images was achieved by integrating CrackDet with Dice loss at a mIoU of 0.7670.

배전선로 회선별단선도 자동생성 알고리즘 (An Auto-drawing Algorithm for the Single Line Diagram of Distribution Systems)

  • 손주환;임성일
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.854-859
    • /
    • 2010
  • Distribution Automation System(DAS) is designed to improve operational efficiency by acquisition and control of remote data using its components such as central computation units, communication network and feeder remote terminal units. A conventional human machine interface of the DAS adopts a schematic diagram which is made by drawing power equipments on the geographic information system map. The single line diagram is more useful than the schematic diagram for the main tasks of distribution system operation such as protective relay coordination, service restoration and loss minimization. Since the configuration of the distribution line is changed according to the relocation of the open tie switches, the auto-drawing algorithm based on the connection between the sections and the switches is an essential technique. This paper proposes a new auto-drawing algorithm for a single line diagram of distribution systems based on tertiary tree and collision avoidance method. The feasibility of the proposed algorithm has been testified for various cases using practical distribution system with 12 feeders.

다구찌의 피드백 제어시스템 내 다수 함수 품질특성 고찰 (Evaluation of Quality Levels with Multiple Probability Distributions Under the Taguchi's Feedback Control System)

  • 송도현;이상헌
    • 경영과학
    • /
    • 제24권1호
    • /
    • pp.77-90
    • /
    • 2007
  • Taguchi assumed that a product characteristic has the uniform distribution in its preventive maintenance limit when deriving the expected loss generated by the quality deviation. But it is reasonable to assume that a product characteristic has the normal distribution than the uniform distribution. On this paper, we first find the optimum inspection interval and the optimum preventive maintenance limit under the truncated triangular distribution. Secondly we use the beta-general distribution and compare with the truncated triangular distribution. By using the numerical examples, we find the optimum inspection interval and the optimum preventive maintenance limit under their distributions. As a result, we find that the beta-general distribution gives the best solution and easy calculation.

태양광 발전과 연계된 직류배전 시스템의 특성연구 (Characteristics Study of DC Distribution System Interconnected with PV System)

  • 서현욱;변병주;이영진;김동진;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.201-202
    • /
    • 2011
  • Existing AC distribution system lower the efficiency of the commercial power, and also generate the conversion loss of renewable energy. In this study, DC distribution system interconnected with PV system is produced, and it is studied about characteristics of the system through the experiments which are uesd load of 3[kW].

  • PDF

유전자 알고리즘을 이용한 배전계통 운영시스템 개발 (The Development of Distribution Power Operating System using the Genetic Algorithm)

  • 김준오;박창호;임성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.480-482
    • /
    • 2000
  • The KEPCO is developing the practical power distribution operating system. The system adopt Genetic Algorithm and will be used loss reduction, load balancing, service planning for large capacity load and various kinds of simulations in the distribution power system. This paper presents the some obstacles and solutions on practical simulation system development, and some problems that need more study.

  • PDF

피더모델링을 이용한 배전계통 재구성 (Distribution Network Reconfiguration Using Feeder Modeling)

  • 김세호;안진오;이수묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1156-1158
    • /
    • 1998
  • This paper Presents two distribution-feeder models to simplify complicated distribution system calculations. These equivalent models are developed to simulate the total series voltage drop at the end of the given feeder and the total line loss of the given feeder accurately. In addition, the proposed models are bidirectional. This means that power infeed can be at either end and the model is accurate. Also, it is shown that the proposed models are suitable for network reconfiguration.

  • PDF

스마트그리드 빅데이터 기반 지역별 배전선로 부하손실 분석 (Regional Analysis of Load Loss in Power Distribution Lines Based on Smartgrid Big Data)

  • 조재훈;이해성;임한민;이병성;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.1013-1024
    • /
    • 2022
  • 전력 계통에서 발생하는 부하손실은 전기품질 수준을 평가하는 지표로 활용되지만, 국내외 전력 유틸리티들의 수익 창출을 방해하는 가장 큰 요인이 된다. 따라서 전력 계통에서 발생하는 부하손실에 대한 정확한 분석은 매우 중요하다. 그러나 빠르게 증가하는 분산전원 연계로 인해 배전계통의 변동성이 증가하여 정확한 손실량을 계산해내는 것이 점점 어려워지고 있다. 본 논문에서는 분산전원 연계로 인해 배전선로에서 발생하는 부하손실의 더욱 정확한 산정을 위하여 스마트그리드 빅데이터 인프라를 구축하였다. 또한, 스마트그리드 빅데이터의 특성 중 하나인 '불확실성'을 제거하기 위한 데이터 전처리기법을 적용하여, 부하손실 분석의 정확도를 높였다. 본 논문에서 수행한 부하손실 분석 결과는 배전설비 투자계획 또는 안정적인 전력공급 신뢰성과 전력품질을 유지하기 위한 배전계통 운영계획에 기초자료로 활용될 수 있다.

다구찌의 피드백 제어 시스템에 관한 연구 (A Study on Taguchi's Feed-back Control System)

  • 김지훈;정해성;김재주
    • 품질경영학회지
    • /
    • 제26권3호
    • /
    • pp.60-70
    • /
    • 1998
  • When driving the expected loss generated by the quality deviation, Taguchi(1991b) assumed that an objective characteristic has the uniform distribution in its control limit. But it is reasonable to assume that an objective characteristic has the normal distribution than the uniform distribution. Since the triangular distribution is similar to the normal distribution and easy to handle as well, in this article, we first find the optimum measurement interval and the optimum control limit under the triangular distribution. Under the normal assumption, the modified method is compared to Taguchi's. Secondly we find the numerical value solution of the optimum measurement interval and the optimum control limit under the normal distribution.

  • PDF