• Title/Summary/Keyword: Loss and damage

Search Result 1,702, Processing Time 0.031 seconds

Damage state evaluation of experimental and simulated bolted joints using chaotic ultrasonic waves

  • Fasel, T.R.;Kennel, M.B.;Todd, M.D.;Clayton, E.H.;Park, G.
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.329-344
    • /
    • 2009
  • Ultrasonic chaotic excitations combined with sensor prediction algorithms have shown the ability to identify incipient damage (loss of preload) in a bolted joint. In this study we examine a physical experiment on a single-bolt aluminum lap joint as well as a three-dimensional physics-based simulation designed to model the behavior of guided ultrasonic waves through a similarly configured joint. A multiple bolt frame structure is also experimentally examined. In the physical experiment each signal is imparted to the structure through a macro-fiber composite (MFC) patch on one side of the lap joint and sensed using an equivalent MFC patch on the opposite side of the joint. The model applies the waveform via direct nodal displacement and 'senses' the resulting displacement using an average of the nodal strain over an area equivalent to the MFC patch. A novel statistical classification feature is developed from information theory concepts of cross-prediction and interdependence. This damage detection algorithm is used to evaluate multiple damage levels and locations.

A Study on the Identification Method of Lubrication Characteristics for Journal Bearing (저널베어링의 윤활상태 판별 기법에 관한 연구)

  • Kim, Myung-Hwan;Lee, Sang-Don;Cho, Yong-Joo
    • Tribology and Lubricants
    • /
    • v.25 no.1
    • /
    • pp.56-60
    • /
    • 2009
  • A journal bearing is used in a hydrodynamic lubrication state, but it becomes a boundary lubrication state that asperity of a contact part touch each other when pressure is too high and an enough oil film is not formed by viscosity change due to lubricating oil temperature. At this time, abrasion due to contact between a journal and a bearing is unavoidable, and scuffing damage that the journal adheres to the bearing occurs if the process is repeated. Damage of the journal bearing is an important problem because it gives huge damage to a machine and can generate large accidents such as economic loss and human life damage. In this study, method for using the pull-up resistor concept was introduced as the monitoring technology. This monitoring system is important to enhance reliability of the engine.

A Study on Port Terminal Operator's Liability under Rotterdam Rules (로테르담규칙상 항만터미널운영자에 관한 연구 - 히말라야조항의 적용과 관련하여 -)

  • Song, Soo Ryun;Min, Joo Hee
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.58
    • /
    • pp.127-148
    • /
    • 2013
  • The Rotterdam Rules provide that port terminal operator may avoid or limit their liability for cargo loss, damage or delay in delivery or breach of any other obligation under the Rules by invoking the provisions that may provide a defence for, or limit the liability of, the carrier. Consequently the port terminal operator who are involved in the provision of maritime services may avoid or limit their liability for cargo loss, damage or delay in delivery or breach of any other obligation under the Rules. The port terminal operator to be applied for the Himalaya clause under the Rules must show that it has the requisite link with a Contracting State. In addition, the port terminal operator performs service to the period of time between the arrival of the goods at the port of loading and their departure from the port of discharge. The port terminal operator's liability for breaches of its obligation is limited to 875 SDR per package or other shipping units, or 3 SDR per kilogram of the gross weight of the goods. In addition, compensation for delay shall be limited to an amount equivalent to two and one-half times the fright payable on the goods delayed.

  • PDF

Ingestion of Korean Red Ginseng after Noise Exposure Can Potentiate Rapid Recovery of Hearing in Mice

  • Kang, Woo-Seok;Chung, Jong-Woo
    • Journal of Ginseng Research
    • /
    • v.34 no.4
    • /
    • pp.336-341
    • /
    • 2010
  • One mechanism of inner ear damage by noise-induced hearing loss (NIHL) is the production of reactive oxygen species (ROS). Because Korean red ginseng (KRG) has an anti-ROS effect in various tissues, KRG may have a role in preventing NIHL. A window period exists in which ROS formations continue after noise exposure, and further damage can be prevented by antioxidants. In this study, we aimed to investigate the effects of KRG after exposure to noise. KRG (200 mg/kg) was fed to mice for 3 days after noise exposure. The change in hearing level was analyzed by measuring the auditory brainstem response. To induce a temporary threshold shift (TTS) of hearing, mice were exposed to 110 dB white noise for 3 hours. Fast recovery of hearing was observed in mice fed KRG 1 hour and 1 day after noise exposure for 3 days. The expression of 8-oxoguanine was not observed in the inner ears of mice fed KRG 1 hour after noise exposure, but was evident in the stria vascularis of mice in the control group (noise exposure only). From this study, we conclude that KRG acted as an effective inhibitor of NIHL in TTS cases.

Variability of plant risk due to variable operator allowable time for aggressive cooldown initiation

  • Kim, Man Cheol;Han, Sang Hoon
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1307-1313
    • /
    • 2019
  • Recent analysis results with realistic assumptions provide the variability of operator allowable time for the initiation of aggressive cooldown under small break loss of coolant accident or steam generator tube rupture with total failure of high pressure safety injection. We investigated how plant risk may vary depending on the variability of operators' failure probability of timely initiation of aggressive cooldown. Using a probabilistic safety assessment model of a nuclear power plant, we showed that plant risks had a linear relation with the failure probability of aggressive cooldown and could be reduced by up to 10% as aggressive cooldown is more reliably performed. For individual accident management, we found that core damage potential could be gradually reduced by up to 40.49% and 63.84% after a small break loss of coolant accident or a steam generator tube rupture, respectively. Based on the importance of timely initiation of aggressive cooldown by main control room operators within the success criteria, implications for improvement of emergency operating procedures are discussed. We recommend conducting further detailed analyses of aggressive cooldown, commensurate with its importance in reducing risks in nuclear power plants.

Eddy current loss calculation of flux shield in the large turbo generator using axi-periodic analysis (Axi-periodic Analysis를 이용한 대형 터보 발전기 단부 Flux Shield의 Eddy Current Loss 산정)

  • Kwon, Soon-O;Lee, Jung-Jong;Hong, Jung-Pyo;Nam, Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.987-989
    • /
    • 2005
  • Axi-periodic analysis using magnetic vector potential is formulated in time harmonic field and applied to the field analysis for the end region of large turbo generator in this paper. By using axi-periodic analysis, the effect of flux shield, one of the structure placed in the end region of large turbo generator to prevent stator end from thermal damage, is studied, and eddy current loss in the flux shield is estimated for operation conditions. 3D FEA is used for the verification of presented analysis method. Because 3D flux distribution can be calculated with 2D modeling, magnetic field showing 3D distribution can be effectively calculated by axi-periodic analysis comparing with 3D FEA.

  • PDF

Localized Plastic Deformation in Heat-Resistant Alloy and Combined Two-Back Stress Hardening Model (내열합금 구조품에서의 국부적 소성변형과 이중후방응력 경화 모델)

  • Yun, Su-Jin;Lee, Sang-Yeun;Park, Dong-Chang;Yoon, Hyun-Gul
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.5
    • /
    • pp.82-88
    • /
    • 2011
  • In the present work, FEM analyses are carried out to investigate the fractures occurred within the structural part in the course of combustion experiment. The loss of structural integrity stems from the localized deformation and the damage induced due to a severe change in the thermal load. Moreover, the two-back stress evolution model is proposed using the Armstrong-Frederick and the Phillips' rules to depict the plastic deformation, and the continuum damage mechanics is also incorporated into the present model. It is noted that the present model is able to formulate a wide range of constitutive description with ease. The numerical results depicts that a severe strain localization and damage evolution can be obtained depending on the dominant back stress.

Localized Plastic Deformation in Heat-Resistant Alloy and Combined Two-Back Stress Hardening Model (내열합금 구조품에서의 국부적 소성변형과 이중후방응력 경화 모델)

  • Yun, Su-Jin;Lee, Sang-Yeun;Park, Dong-Chang;Yoon, Hyun-Gul
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.272-278
    • /
    • 2011
  • In the present work, FEM analyses are carried out to investigate the fractures occurred within the structural part in the course of combustion experiment. The loss of structural integrity stems from the localized deformation and the damage induced due to a severe change in the thermal load. Moreover, the two-back stress evolution model is proposed using the Armstrong-Frederick and the Phillips' rules to depict the plastic deformation, and the continuum damage mechanics is also incorporated into the present model. It is noted that the present model is able to formulate a wide range of constitutive description with ease. The numerical results depicts that a severe strain localization and damage evolution can be obtained depending on the dominant back stress.

  • PDF

Damage Evaluation of Porcelain Insulators Using the Frequency Response Function (주파수응답함수(FRF)를 이용한 자기 애자의 손상평가)

  • Choi, In-Hyuk;Son, Ju-Am;Oh, Tae-Keun;Yoon, Young-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.2
    • /
    • pp.122-128
    • /
    • 2019
  • Porcelain insulators have been used mainly for power line fixing and electrical insulation in transmission towers. Porcelain insulators have generally a 30 years desired life, but over 50% exceed their life expectancy. Since the damage to porcelain insulators is usually accompanied by enormous loss of human resource material, their efficient maintenance has emerged as an important issue. In this regard, this study applied a frequency response function (FRF) for integrity assessment of the insulator. The characteristics of the FRF according to damage types were identified and analyzed by the change in natural frequencies, curve shape, attenuation, and Nyquist diagram stability. The results showed significant differences in the FRF according to damage types, which can be used as basic data for the effective integrity assessment of porcelain insulators.

A Study on the Cause and Improvement Plans of Construction Monitoring Sensors Decline in Durability (건설 계측센서의 내구연한 저하원인 및 개선방안 연구)

  • Woo, Jong-Tae
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.28-38
    • /
    • 2019
  • Purpose: The purpose of this study is to contribute to improvement of measurement management level of construction structure and technology development of monitoring sensor by presenting the detailed causes and improvement plans of construction monitoring sensor's decline in durability. Method: The causes and improvement plans of the durability degradation of the construction monitoring sensor were divided into the construction field and the electric, electronic field. The detailed status was reviewed. Results: In the field of construction, approval and inspection, inspection and testing, verification and calibration, and minimization of loss and damage ratio were reviewed. In the field of electric and electronics, sensor package and sealing, disconnection of stress concentration area, damage caused by lightning and corrosion were reviewed. Conclusion: It is expected that the durability of monitoring sensors applied to the construction site will become longer than the present status based on the study that analyzed causes and improvement plans of construction monitoring sensor's decline in durability in the field of construction and electric, electronic devices.