Abstract
Purpose: The purpose of this study is to contribute to improvement of measurement management level of construction structure and technology development of monitoring sensor by presenting the detailed causes and improvement plans of construction monitoring sensor's decline in durability. Method: The causes and improvement plans of the durability degradation of the construction monitoring sensor were divided into the construction field and the electric, electronic field. The detailed status was reviewed. Results: In the field of construction, approval and inspection, inspection and testing, verification and calibration, and minimization of loss and damage ratio were reviewed. In the field of electric and electronics, sensor package and sealing, disconnection of stress concentration area, damage caused by lightning and corrosion were reviewed. Conclusion: It is expected that the durability of monitoring sensors applied to the construction site will become longer than the present status based on the study that analyzed causes and improvement plans of construction monitoring sensor's decline in durability in the field of construction and electric, electronic devices.
Keywords
construction monitoring sensor; period of durability construction field; electric and electronic field; loss and damage ratio;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Korea Water Resources Corporation (2006), A study on the improvement of instrumentation programs for fill dams, pp. 245-252.
2 Korea Water Resources Corporation (KWRC) and Kim, K.S. (2008), Improving the durability and training methods of dam instrumentation, pp. 25-40.
3 Nam, S.S. (2000). "Case studies on the damage ratio of monitoring sensor." Proceedings of the Korean Geotechnical Society Spring Conference at Information Technical Committee, Vol. 1, No. 1, pp. 5-10.
4 Seoul Metropolitan Infrastructure Headquarters (2015). Improvement plan of Seoul subway monitoring management, pp. 70-80.
5 Seoul Metropolitan Rapid Transit Corporation (2002). Seoul subway maintenance monitoring, pp. 234-236.
6 Woo, J.T. (2010), "A study of the present state analysis and development plans about construction monitoring and monitoring industry." Journal of Korean Society of Civil Engineers, Vol. 30, No. 2D, pp.163-169.
7 Woo, J.T. (2013), "A study on estimation of the total loss and damage ratio of maintenance monitoring sensor of subway tunnel." Journal of Korean Tunnelling and Underground Space Association, Vol. 15, No. 1, pp. 25-31.   DOI
8 Woo, J.T. (2017). "A study on behavior of the earth retaining structure by field measurement and numerical analysis." Journal of Korea Society of Disaster Information, Vol. 13, No. 3, pp. 286-295.   DOI
9 Woo, J.T. (2018a). "A study on the regulation of durability standard of underground structures monitoring sensors." Journal of Korean Tunnelling and Underground Space Association, Vol. 20, No. 1, pp. 73-81.   DOI
10 Woo, J.T. (2018b)."A study on the loss and damage ratio of railroad tunnel maintenance monitoring sensor." Journal of Korea Society of Disaster Information, Vol. 14, No. 3, pp. 262-270.   DOI
11 Woo, J.T., Lee, K.I. (2012). "A study on establishment of measurement and analysis frequency of maintenance monitoring in tunnel." Journal of Korean Tunnelling and Underground Space Association, Vol. 14, No. 2, pp. 117-129.   DOI
12 Woo, J.T., Lee, R.C. (2008). Construction monitoring engineering, Goomi Publishing Co., pp. 15-25.