A Study on Isolated DCM Converter for High Efficiency and High Power Factor

  • Kwak, Dong-Kurl
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.477-483
    • /
    • 2010
  • This paper is studied on a novel buck-boost isolated converter for high efficiency and high power factor. The switching devices in the proposed converter are operated by soft switching technique using a new quasi-resonant circuit, and are driven with discontinuous conduction mode (DCM) according to pulse width modulation (PWM). The quasi-resonant circuit makes use of a step up-down inductor and a loss-less snubber capacitor. The proposed converter with DCM also simplifies the requirement of control circuit and reduces a number of control components. The input ac current waveform in the proposed converter becomes a quasi sinusoidal waveform in proportion to the magnitude of input ac voltage under constant switching frequency. As a result, it is obtained by the proposed converter that the switching power losses are low, the efficiency of the converter is high, and the input power factor is nearly unity. The validity of analytical results is confirmed by some simulation results on computer and experimental results.

Freezing and Thawing Properties of High Strength Concrete Using Recycled Coarse Aggregate (재생굵은골재를 사용한 고강도 콘크리트의 동결융해 특성)

  • Sung , Chan-Yong;Im , Sang-Hyuk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.2
    • /
    • pp.59-66
    • /
    • 2004
  • This study was performed to evaluate the freezing and thawing properties of the high strength concrete using recycled coarse aggregate. The recycled coarse aggregate replaced natural crushed aggregate by 0%, 25%, 50%, 75% and 100%. The compressive strength of the concrete using recycled coarse aggregate showed more than 300 kgf/$cm^2$ at the curing age 28 days. The mass loss ratio by freezing and thawing was less than 1% at all mix type. The relative dynamic modulus of elasticity was decreased with increasing the freezing and thawing cycles. Also, the durability factor by the freezing and thawing was decreased with increasing the content of recycled coarse aggregate. But, the recycled concrete except 100% recycled coarse aggregate showed 60 or more durability factor in the freezing and thawing 300 cycles. Accordingly, these recycled coarse aggregate can be used for high strength concrete.

Prediction of Vehicle Fuel Consumption on a Component Basis (가솔린 차량의 각 요소별 연료소모량 예측)

  • 송해박;유정철;이종화;박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.203-210
    • /
    • 2003
  • A simulation study was carried to analyze the vehicle fuel consumption on component basis. Experiments was also carried out to identify the simulation results, under FTP-75 Hot Phase driving conditions. and arbitrary driving conditions. A good quantitative agreement was obtained. Based on the simulation, fuel energy was used in pumping loss(3.7%), electric power generation(0.7%), engine friction(12.7%), engine inertia(0.7%), torque converter loss(4.6%), drivetrain friction(0.6%), road-load(9.2%), and vehicle inertia(13.4%) under FTP-75 Hot Phase driving conditions. Using simulation program, the effects of capacity factor and idle speed on fuel consumption were estimated. A increment of capacity factor of torque converter resulted in fuel consumption improvement under FTP-75 Hot Phase driving conditions. Effect of a decrement of idle speed on fuel consumption was negligible under the identical driving conditions.

Estimation of Load Characteristic Factor Considering The Load Pattern and Seasonal Characteristic for Consumer (수용가의 형태와 계절별 특성을 고려한 부하특성계수 재 산정)

  • Hwang, H.M.;Jang, S.I.;Kim, K.H.;Kim, J.E.;Rho, D.S.;Jeong, I.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.450-453
    • /
    • 2003
  • This paper presents the estimation on Load Characteristic Factor(k) which is considered to load pattern and seasonal characteristic of consumer. We can calculate the loss of distribution networks through the equation composing of Load Factor(LF), Loss Load Factor(LLF) and load characteristic factor(k). This equation is similar to the method of Regulator-General Victoria, Australia. Generally, the conventional method for calculating the distribution losses uses k with a constant value from 0.1 to 0.3. However, the k which is a relationship between LF and LLF can be varied by load pattern and seasonal characteristics. It is necessary to estimate the k according to load characteristics. This paper shows the result for recalculating k using the KEPCO's SOMAS data measured in distribution networks.

  • PDF

A Method of Analysis to Predict Sound Transmission Loss of an Extruded Aluminum Panel for Use on Railway Vehicles (철도차량용 알루미늄 압출재의 음향 투과손실 예측에 관한 연구)

  • Kim, Kwanju;Lee, Jun-Heon;Kim, Dae-Yong;Kim, Seock-Hyun
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.1
    • /
    • pp.20-25
    • /
    • 2013
  • The frame elements of modern high speed trains are typically fabricated with extruded aluminum panels. However, the sound transmission loss (STL) of extruded aluminum panels is less satisfactory than flat panels with the same surface density. This study proposes a method for prediction of the sound transmission loss of extruded aluminum panels using finite element analysis. The panel is modeled by finite element analysis, and the STL is calculated using a measure of Sommerfeld radiation at the specimen surface, boundary conditions, and the internal loss factor of the material. In order to verify the validity of the predicted value, intensity transmission loss was measured on the aluminum specimen according to ASTM E2249-02. The proposed method of analysis will be utilized to predict the sound insulation performance of extruded aluminum panels for railway vehicles in the design stage, and to establish measures for their improvement.

Analysis of soil loss on sloping land considering daily rainfall (일단위 강우량을 고려한 경사지의 토양유실량 분석)

  • Kim, Won-Jun;Park, Bum-Soo;Lee, Jae-Hyeok;Ryu, Ji-Chul;Jang, Chun-Hwa;Kim, Young-Sug;Park, Hwa-Yong;Lim, Kyoung-Jae
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.4
    • /
    • pp.739-745
    • /
    • 2011
  • The MUSLE was utilized in this study to estimate soil erosion using daily precipitation which was main influential factor in soil loss estimation. Various scenarios were simulated to evaluate how transition of slope, agricultural products and precipitation could affect soil loss in the field. It was found that slope was the most affecting factor in soil loss estimation. Especially 1.8 times the soil loss was expected with potato at 45% slope compared with codonopsis at same slope with MUSLE model. Fortunately, farmers had planted codonopsis at this slope to reduce soil erosion from this steep slope. As shown in this study, the MUSLE method could be utilized to determine optimum crop type for each field with various slope conditions to minimize soil erosion. This approach utilized in this study could be applied to other agricultural watersheds to evaluate various soil erosion conditions.

Magnetization Loss Characteristics of a Stacked Bi-2223 Conductor (적층 Bi-2223도체의 자화손실 특성)

  • Ryu, Gyeong-U;Han, Hyeong-Ju;Choe, Byeong-Ju;Na, Wan-Su;Ju, Jin-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.10
    • /
    • pp.554-559
    • /
    • 2002
  • The at loss is an important issue in the design of superconducting cables and transformers. In these devices the Bi-2222 tapes are usually placed face-to-face. In such arrangements ac loss is influenced by adjacent tapes. The effect is investigated by measuring the magnetization loss in the stacked conductor, which consists of various numbers of Bi-2223 tapes. For the single tape the magnetization loss in perpendicular field is larger than that in parallel field by about a factor 10. This agrees well with the prediction for hysteresis loss in slab and strip models. For the stacked conductor in perpendicular field the magnetization loss at low fields is greatly decreased, compared to the loss of the single tape. However the loss at high fields is nearly unaffected. This behavior is well described by the slab model.

Choice technique develovement of transformer core (변압기 코아의 선정 기술 개발)

  • Lee, O.K.;Kim, S.Y.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1604-1606
    • /
    • 2003
  • In this paper, investigated the core of transformer of high power factor and high effectiveness about design and choice technology. Transformer that use existent general core and material is high no-load loss power. Presented core choice method that can reduce loss. Could do to reduce loss according to choice technology of use material more than about 10 (%). Presented classification and check list by Core's type.

  • PDF

Numerical Study on Tip Clearance Effect on Performance of a Centrifugal Compressor (익단간극이 원심압축기 성능에 미치는 영향에 관한 수치해석적 연구)

  • Eum, Hark-Jin;Kang, Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.389-397
    • /
    • 2003
  • Effect of tip leakage flow on through flow and performance of a centrifugal compressor impeller was numerically studied using CFX-TASC flow. Seven different tip clearances were used to consider the influence of tip clearance on performance. Secondary flow and loss factor were evaluated to understand the loss mechanism inside the impeller due to tip leakage flow. The calculated results were circumferentially averaged along the passage and at the impeller exit for quantitative discussion. Tip clearance effect on Performance could be decomposed into inviscid and viscous components using one dimensional equation. The inviscid component is related with the specific work reduction and the viscous component is related with the additional entropy generation. Two components affected Performance equally. while efficiency drop was mainly influenced by viscous loss. Performance and efficiency drop due to tip clearance were proportional to the ratio of tip clearance to exit blade height. A simple model suggested in the present study predict performance and efficiency drop quite successfully.

A Study on the Development and Optimization Design of Isolator by Using the 3D Simulator (3D Simulator를 이용한 아이솔레이터 최적화 설계 및 개발에 관한 연구)

  • Jung Seung-Woo;Choi U-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.229-238
    • /
    • 2006
  • In this paper, developed study about isolator that after design and optimizes center strip to use 3-D simulator. We use the factor about the change and propose simple mode of the simulation. Design strip line that center frequency is 1.85 GHz by software that use 3-D finite element method(FEM) and confirmed variable. Developed isolator were shown that more than isolation 25 dB, reflection loss has the more than 25 dB and insertion loss does not 0.2 dB. We could confirm that compare with simulation and manufacture sample propertied agrees more than 90 %.