• Title/Summary/Keyword: Loss Analysis

Search Result 8,452, Processing Time 0.04 seconds

Analysis of effect that land cover change get in Soil Loss by Forest fire (산불에 의한 토지피복변화가 토양유실에 미치는 영향분석)

  • 양인태;김재철;유영걸;오명진
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.353-358
    • /
    • 2003
  • Soil loss by the rains has effect on natural environment. But It is difficult to find out the data that is surveyed in watershed. In this paper, we chose USLE erosion model, which could be connected easily with GSIS and available generally, and extracted factors which is entered model by using GSIS spatial analysis method. Especially, As revised USLE model, It should be applied in watershed and as it calculated soil loss before forest fire and behind, it analysed the degree that it have an effect on soil loss. Each analyzed factors and the result of soil loss estimate consist of 22m-pixel size, we could identify soil loss by each pixel and distribution form.

  • PDF

Measurement and Analysis of Loss in Optical Directional Couplers

  • Leepila, R.;Jangsilp, R.;Noppanakeepong, S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.484-487
    • /
    • 2004
  • Symmetric directional couplers are widely used in interferometers, switches, and various signal processing devices. Recently, several optical couplers using multimode fibers were reported, but these suffer from inefficient coupling of light into a branching fiber and/or low directivity. This paper presents the measurement and analysis of loss in the connection of optical fibers via the optical directional couplers. The functionality of the device is based on the principle that is symmetrical, the power in excited mode can be unambiguously directed into one of the output channel by varying and of its parameters. In this experiment, we measure the power of loss in the optical directional coupler at various radius of curvature. Before the measurement of loss in x-coupler, we polish the contact of the fiber surface in order that light can penetrate through another port. The results show that, when the radius of curvature is increased, the loss power is decreased and also approaches of the straight line case.

  • PDF

Research on the Transmission Loss Analysis of the Honeycomb Structure's Floor Section (허니콤 구조물을 갖는 차체 바닥의 투과손실 해석기법 연구)

  • Kim, Kwan-Ju;Kim, Sang-Su;Park, Jin-Kyu
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • Sound transmission characteristics are investigated on the test specimen for the railway vehicle's floor section. Transmission loss on the honeycomb structure has been examined experimentally with the reverberation chamber. Predicted transmission loss values using NASTRAN, AUTOSEA2, are compared with measured Haloes and the effect of resonance on the transmission loss is identified. Transmission loss of different shapes of honeycomb structure are predicted.

A Study on the Flow Friction Loss of a Shrouded Rotating Disk (밀폐된 단일 회전 원판 주위의 유동손실에 관한 연구)

  • 조성욱;임윤철
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.292-297
    • /
    • 2003
  • The fundamental fluid mechanics associated with the rotation of a smooth plane disk enclosed within a cylindrical chamber have been studied experimentally. In order to acquire systematic information pertinent to this problem torque and friction loss data were obtained over a wide range of disk Reynolds numbers for axial clearance-disk radius ratio H/R from 0.025 to 0.2 and radial tip gap-disk radius ratio s/R from 0.021 to 0.105. Loss analysis of hard disk drive (HDD) is presented to describe the contribution of windage loss of a rotating disk. The minimum loss form factor of HDD can be obtained from this analysis at each operation conditions.

Iron Loss Analysis of Induction Motor Considering Harmonics of the Flux Density (고조파 분석을 통한 유도 전동기의 철손해석)

  • Lee, Jae-Gun;Lee, Jeong-Jong;Ha, Kyoung-Ho;Hong, Jung-Pro;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.91-93
    • /
    • 2002
  • This paper presents a calculation method of iron loss in Induction Motor which is based on 2D Transient Finite Element Method. Iron loss is evaluated by the frequency analysis of flux density waveforms using Discrete Fourier Transforms (DFT) and iron loss curves data. Then. the distribution of loss and the total loss are obtained. The validity of this method is verified by the comparison of the estimated values with measured ones.

  • PDF

A study on the flow friction loss of a shrouded rotating disk (밀폐된 단일 회전 원판 주위의 유동손실에 관한 연구)

  • 조성욱;임윤철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.159-165
    • /
    • 2001
  • The fundamental fluid mechanics associated with the rotation of a smooth plane disk enclosed within a cylindrical chamber have been studied experimentally. In order to acquire systematic information pertinent to this problem torque and friction loss data were obtained over a wide range of disk Reynolds numbers for axial clearance-disk radius ratio H/R from 0.025 to 0.2 and radial tip gap-disk radius ratio s/R from 0.021 to 0.105. Loss analysis of hard disk drive(HDD) is presented to describe the contribution of windage loss of a rotating disk. The minimum loss from factor of HDD can be obtained from this analysis at each operation conditions.

  • PDF

Transmission Loss Prediction of the High Speed Railway's Wall Section (고속철도 차량 벽면의 투과손실값 예측)

  • Kim, Kwan-Ju;Park, Jin-Kyu
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.1 s.32
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to calculate transmission loss of the high speed railway's wall section accurately. Transmission loss measurement of ideal case i.e. the wall in the laboratory condition was carried out in first, which results were compared with those by statistical energy method. Transmission loss values of high speed railway calculated out by experimental method are compared with those from closed form solution. Commercial statistical energy analysis was also used to predict the outside pressure level using those measured transmission loss values. Simple SEA model could estimate reasonable exterior sound pressure level.

Radiation Effects on ${\gamma}$-Ray Irradiated Ethylene Propylene Rubber using Dielectric Analysis

  • Kim, Ki-Yup;Ryu, Boo-Hyung;Lee, Chung;Lim, Kee-Joe
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.2
    • /
    • pp.48-54
    • /
    • 2003
  • To evaluate the radiation degradation of ethylene propylene rubber (EPR), radiation effects on EPR were investigated by using dielectric analysis and thermal-gravimetric analysis. Permittivity, loss factor, tan$\delta$, and thermal decomposition temperature were observed for ${\gamma}$-ray irradiated EPR. As the radiation dose was increased, the peak temperature of the loss factor and tans of EPR were increased and loss factor and tan$\delta$ at peak temperature were decreased. Activation energies were calculated using loss factor and thermal decomposition for ${\gamma}$-ray irradiated EPR as well. The trends of both calculated activation energies showed the same tendencies as radiation dose was increased.

Loss Analysis according to Configuration Method of AC Module Integrated Converter for Photovoltaic System (태양광 발전 시스템용 AC 모듈 집적형 전력변환기의 구성 방식에 따른 손실 분석)

  • Kang, Seung-Hyun;Son, Won-Jin;Ann, Sangjoon;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.311-318
    • /
    • 2020
  • A photovoltaic (PV) system uses an AC module integrated converter (MIC) to operate PV cells at a maximum power point (MPP) and for high efficiency. The MPP of a PV cell varies depending on partial shading conditions, and loss occurs differently according to the configuration method of the PV-MIC. Therefore, this study compares the losses of passive components and power semiconductors according to the partial shading conditions of the PV module. Theoretical loss analysis is performed using parameters for the datasheet and PSIM simulation results. Analysis results verify that the one-stage PV-MIC demonstrates high efficiency.

A Second-Order Analysis of VM Heat Pumps (VM열펌프의 2차해석)

  • Choi, Y.S.;Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF