• Title/Summary/Keyword: Loop-Type Ground

Search Result 48, Processing Time 0.019 seconds

A Study on the description of Horizontal Geothermal Heat pump Type on Small Residential House (소규모 주택에 대한 수평형 지열 히트펌프 형태 결정에 관한 연구)

  • Yun, Jang-Ryeol;Cho, Sung-Woo;Choi, Jung-Min
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.328-332
    • /
    • 2011
  • The conclusion is derived from the arranged results and using a simulation by determining the shape of an optimum heat pump which is appropriate for small scale houses. It is concluded as 3 meters long for the laying depth of underground piping of the horizontal type geothermal heat pump system in regard to the 5 RT capacity standard that is suitable for a small scale house. The shape of the horizontal type geothermal heat pump system for a small scale house is theThree pipe shape whose trench length is short and pipe length laid in a trench is short. It is 9 for the number of laying pipes that is most appropriate to system.

  • PDF

A Study on the Improvement of Water-Leakage Detection Reliability in Local Heating System (지역난방배관의 누수감지 신뢰성 향상에 관한 연구)

  • 신춘식;안영주;변기식
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.66-72
    • /
    • 1999
  • Local heating transportation pipe has sensor and return lines to detect water-leakage. There are impulse and resistance comparison measurement types for a water-leakage detection. The impulse type shows large detection error within a measurement range. Since the resistance comparison type can find a comparative accurate single water-leakage point in the measurement range of heating pipe, it has been used to detect water-leakages these days. However if the multi water-leakages are happened in the measurement range of transportation pipe. the resistance comparison type shows a detection error point by the parallel resistance between a detection sensor line and ground. But the detection error will be minimized by the divided transportation pipe loops. In this research, it suggests the design of remote controlled detection system which can divide a large pipe loop and a possible single water-leakage measurement process in each divided loops.

  • PDF

Numerical analysis study of reinforced method (loop type) at the double-deck tunnel junction (복층터널 분기부에서의 보강공법(루프형 강선)에 따른 수치해석 연구)

  • Lee, Seok Jin;Park, Skhan;Lee, Jun Ho;Jin, Hyun Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.5
    • /
    • pp.823-837
    • /
    • 2018
  • Congestion of the city with the rapid industrial development was accelerated to build complex social infrastructure. And numerous structures have been designed and constructed in accordance with these requirements. Recently, to solve complex urban traffic, many researches of large-diameter tunnel under construction downtown are in progress. The large-diameter tunnel has been developed with a versatile double-deck of deep depth tunnel. For the safe tunnel construction, ground reinforcement methods have been developed in the weakened pillar section like as junction of tunnel. This paper focuses on evaluation of the effects of new developed ground reinforcement methods in double-deck junction. The values of reinforcement determined from the existing and developed methods were compared to each other by numerical simulation.

Time Series Analysis of the Effect of Ground-source Heat Pumps on Groundwater Characteristics (시계열 분석을 이용한 지열히트펌프 가동에 따른 지하수특성변화 해석)

  • Mok, Jong-Gu;Lim, Hong-Gyun;Jang, Bum-Ju;Park, Yu-Chul;Lee, Jin-Yong
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • Time series analysis was applied to groundwater level, water temperature, and electrical conductivity data obtained from monitoring wells around ground-source heat pumps at Sangji University of Wonju (standing column well type) and at Jungwon University of Goesan (closed loop type), from 21 May to 12 October 2010. We found large temporal variations in the characteristics of groundwater at Wonju, but only minor variations at Goesan. These results may improve our understanding of the effects of ground-source heat pumps on the characteristics of surrounding groundwater, according to the installation method for the pumps.

Daily Heating Performance of a Ground Source Multi-heat Pump at Heating Mode (지열원 물대공기 멀티 히트펌프의 일일 난방 운전 특성에 관한 실증 연구)

  • Choi, Jong-Min;Lim, Hyo-Jae;Kang, Shin-Hyung;Moon, Je-Myung;Kim, Rock-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.527-535
    • /
    • 2009
  • The aim of this study is to investigate the daily heating performance of ground source multi-heat pump system with vertical single U-tube type GLHXs, which were installed in a school building located in Cheonan. Daily average COP of heat pump unit on Jan. 12th, 2009 at heating mode was lower than it on Nov. 10th, 2008 and Dec. 15th, 2008, because of lower EWT of the outdoor heat exchanger and relatively smaller size of condenser and evaporator. But, the system COP on the former was higher than it on the latter because ground loop circulating pump was operated in rated speed. It is suggested that the new algorithms to control the flow rate of secondary fluid for GLHX according to load change have to be developed in order to enhance the performance of the system COP.

Performance Evaluation and Economic Estimation of Ground Source Heat Pump Cooling and Heating System (지열 냉난방 시스템의 성능 및 경제성 평가)

  • Lim Hyo Jae;Song Yoon Seok;Kong Hyoung Jin;Park Seong Koo
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.296-300
    • /
    • 2004
  • Performance evaluation and economic estimation were conducted on the water to water GSHP (Ground Source Heat Pump) installed in existing building. Ground heat exchanger was a closed vertical loop type and sized to be 5 boreholes and 100m depth per borehole. Operation efficiency of the system shows that, COP increased from 3.0 to 4.2 with entering water temperature in heating operation, however, COP decreased from 5.0 to 3.7 in cooling operation. Economic estimation was analyzed by LCC (Life Cycle Cost) method and it showed that GSHP could save 68% of cost compare to the conventional oil source. Thus, despite of the large amount of initial cost, GSHP has a economic advantage to the other energy sources.

Design of the Compact Microstrip Bandpass Filter by using DGS Resonator (DGS 공진기를 이용한 소형 마이크로스트립 대역통과 필터의 설계)

  • Cho, Young-Bin;Jun, Kye-Suk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.2A
    • /
    • pp.147-152
    • /
    • 2005
  • In this paper, we have proposed a novel DGS(Defected Ground Structure) resonator and has designed the band -pass filter using the proposed ${\subset}$ stub-I type DGS resonator. This structure has strong advantages that can vary the retune loss at the passband freely and also can easily tune the attenuation pole frequency at the stopband. The bandpass filter can be made more smaller than the existing filters and be used to find the various applications for eliminating the harmonics and spurious mode at IMT-2000 band.

Comparative Evaluation of Loop-Mediated Isothermal Amplification (LAMP) and Conventional PCR for Detection of Shiga-Toxin-Producing Escherichia coli (STEC) in Various Food Products

  • Hyejin Jang;Yong Sun Cho
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.347-355
    • /
    • 2023
  • In this study, polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) were compared in terms of their ability to detect shiga-toxin-producing Escherichia coli (STEC). Various foods were artificially inoculated with STEC to evaluate the limit of detection (LOD), limit of quantification (LOQ), sensitivity, specificity, and efficiency of PCR and LAMP. The LODs were ≤104 and ≤103 CFU/mL for PCR and LAMP, respectively. The LOQs did not differ between PCR and LAMP. However, of the four considered food types, the sensitivities differed by a maximum of 11.1% for seasoned meat and by a minimum of 8.1% for ground beef. LAMP had higher sensitivity than that of PCR and 100% specificity for all four food types. Therefore, LAMP is a reliable molecular method for detecting STEC as comparable to PCR assay, and its specificity and sensitivity are superior to those of PCR, depending on the food type.

Study on Pile Cloth Rugs Produced after the Late Joseon Period (조선 말기 이후 첨모직 깔개에 관한 연구)

  • Park, Yoon-Mee;Oh, Joon Suk
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.4
    • /
    • pp.84-107
    • /
    • 2018
  • Cheommojik is a pile cloth, a type of textile whose surface is covered with short piles. The term chaedam was used during the late Joseon dynasty to refer to pile cloth rugs, while the terms yoongjeon, dantong and yangtanja were used in the early twentieth century. Various documents, newspaper articles and photographs confirm that pile cloth rugs were used by the general public as well as the royal family from the late Joseon dynasty onward, and that there were domestic manufacturers of such rugs at that time. This study investigated six pile cloth rugs that were produced after the late Joseon dynasty, five of which feature Persian knots made of cut pile, the other being made with the loop pile method. The cut pile rugs are rectangular in shape and measure between 72-98cm by 150-156cm; and they are decorated in the middle with patterns of butterfly, deer, and tiger or the ten longevity symbols, and along the edges with patterns composed of 卍 symbols. The ground warp of all six rugs are made from cotton yarn, while the ground weft is made of cotton yarn on three pieces, wool on one piece and cotton and viscose rayon. The ground weft yarn from four pieces are Z-twist yarn made with two or more S-twist cotton yarn. Four to six colors were used for the pile weft, all being natural colors except for red. Two or more S- or Z-twist yarn were twisted together in the opposite twist for the pile weft, with the thickness determining the number of threads used. Six or more weft threads were used to make the start and end points of the rug; and the ground warp ends were arranged by tying every four of them together. For the left and right edges, three or more threads were wrapped together into a round stick-like form, and the second and third inner ground warps from the edges were stitched on to the wrapped edge. For the loop pile, loops were made in the direction of the warp; the ground warp and the ground weft may have been made with cotton, the pile warp with wool yarn. An analysis of the components of three rugs was conducted to determine which types of animal hair were used for the pile weft. Despite some inconclusive results, it was revealed that goat hair and fat-tailed sheep hair were used, raising the possibility that various kinds of animal fur were used in the production of pile cloth rugs. The six rugs examined in this study are estimated to have been made between the late 1800s and the early 1900s. Although the manufacturer of the rugs cannot be confirmed, we concluded that the rugs were produced in Korea after referring to the documentation of the domestic production of pile cloth rugs during the aforementioned period and the form and placements of the patterns on the rugs.

Study on the performance analysis of SCW geothermal system by simulation and monitoring (모니터링 및 시뮬레이션을 통한 SCW형 지열 시스템의 성능인자 분석에 관한 연구)

  • Lee, SangJun;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.2
    • /
    • pp.8-15
    • /
    • 2013
  • Recently, an interest in the use of renewable energy has been growing up due to the rise of raw material price, international oil price and depletion of fossil energy. Ground source heat pump system has a high efficiency by using the constant temperature of underground and various types of the systems have been installed and utilized in the building. there are few studies on the system performance factors in the SCW system. Furthermore, even though the performance of the system depends on the temperature of heat source, the research on their relationship is rare. In this research, in order to analyze the performance factor for the open-loop system the monitoring of the real building with the standing column well systems and the simulation with building model were conducted.