• Title/Summary/Keyword: Loop Type

Search Result 951, Processing Time 0.027 seconds

A Presentation on the Manual Hydraulic Calculation Method of the Loop Type Fire Sprinkler System (Loop형 스프링클러 설비의 수리계산 방법에 대한 제시)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2015
  • There are three kinds of design method of the fire sprinkler systems. Grid type is connected all branch as a trapezoid. Loop type is connected cross-mains like circle. The last one is a tree type most commonly used. Grid type needs computer program to calculate the friction loss and flow rate apart from very simple form. In loop type, manual calculation is possible. Design engineer can draw up and calculate the demands without computer program. Because water supplies two direction in loop type, friction loss is smaller than tree type. Water distribution in operation area is uniform because of the small differences of sprinklers discharge pressure. Loop type is superior to tree type in respect of total pressure and flow rate. Using the small diameter pipe, the labor and construction cost will be decreased in the end. Loop type sprinkler design is rarely laid out because design engineers don't know the method. This paper is intended to inform that the loop type is better than the tree type in performance and economic point of view. And also this paper intend to use the loop type easily and widely.

A Study on Standardization Method Establishment of Multi Water-Loop System using Multi Water Resources (다중수원을 활용한 멀티워터 루프시스템의 표준화방안 구축에 관한 연구)

  • Lee, Hyundong;Lee, Joonhyung;Kwak, Pilljae
    • KCID journal
    • /
    • v.21 no.1
    • /
    • pp.109-117
    • /
    • 2014
  • Multi water-loop system is the efficient customer centered facilities of water supply by utilizing the multi water resources. Multi water-loop system is divided into various types. The system is classified potable and non-potable type. Mostly, the potable type utilizes surface water and ground water. However, the non-potable type utilize the multi water resources, such as rain water, sea water, reclaimed water, etc. Selective intake is possible when characteristics of region, physiographic condition and purpose of use are considered. For instance, downtown type, new-city type, agriculture type, island type are available. For development and application of these multi water-loop system, standardization is needed. For standardization, several methods are given; design principles, selection and composition method of multi water-loop system structure, BIM/GIS application method, safety inspection method. Consequently, a road map of design standardization method can be established. In this road map, there are three parts for the standardization of multi water-loop system. Three parts are the considerations, base material and ways of standardization. Design standardization become close when this road map followed by someone who plan the multi water-loop system. In this way, loop system's development is more efficient and economic. In hereafter research, each type's characteristic will be analysed and standardization methods can be established.

  • PDF

ON THE IDENTITIES OF BOL-MOUFANG TYPE

  • Solarin, A.R.T.
    • Kyungpook Mathematical Journal
    • /
    • v.28 no.1
    • /
    • pp.51-62
    • /
    • 1988
  • In this work we study properties of five identities of Bol-Moufang type (1). We establish a necessary and sufficient condition for a loop to be an RC-loop. A corollary to this is the condition for a Bol loop to be an RC-loop. Some proerties of a generalization of RC-loops are discussed. We also state the relationship between the supernucleus M(G) of a loop G and the nucleii of loops which do not have the inverse property. Finally, we give two tables of non-associative RC-loops of order 16, which are not Bol loops.

  • PDF

A Loop Configuration Algorithm Considering Constraints in Distribution System (제약 조건을 고려한 배전 계통 루프 구성 알고리즘)

  • Cho, Bo-Hyeon;Cho, Sung-Min;Park, Jin-Hyun;Sin, Hee-Sang;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.26-31
    • /
    • 2011
  • In this paper, we focused on the loop distribution system to solve the international issues of energy depletion and global warming. The conventional method of reconfiguration of distribution system was moving open points of switches from an actual switch position to another, while an appropriate switch must be opened to preserve the radial structure and this procedure is continued til there is no further loss reduction. However, the loop distribution system is the best optimization method to minimize loss than the other methods which is preserving radial structure. So we analyzed 3 types of loop distribution system upgraded from radial distribution system by changing normally open switch to normally closed switch. The simple 3 types of model system for simulation were composed, and each types of loop system were simulated in accordance with varying parameters. As a result of simulations, the loss reduction was different for each types of loop distribution system and each loop types have constraints for composing loop distribution system. The algorithms propose the method how to construct loop distribution system regarding constraints. Type I that needs least requirements get least loss reduction and Type III that needs most requirements get maximum loss reduction. On the other hand, Type I was most feasible distribution system to be realized.

A Design Guide to Type-3 PLLs for FMCW Radars (FMCW 레이더용 타입-3 PLL의 설계 가이드)

  • Hwang, In-Duk;Kim, Chang-Hwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.4
    • /
    • pp.70-79
    • /
    • 2012
  • A design guide to type-3 PLLs for FMCW radars is provided. To do that, the cross-over frequencies of the open-loop transfer functions were normalized to 1 Hz and closed-loop properties were compared through simulations using Pspice. As a result, several guides to design type-3 PLLs were provided: 1) secure 45 degrees of phase margin, 2) locate two zeroes at an identical frequency, and 3) poles may be added to raise order of the PLL at higher frequencies than the cross-over frequency of the open-loop transfer function about ten times.

Printed Type Half-wavelength Small Loop Antenna (프린트형 반파장 소형 루프 안테나)

  • Ryu, Hong-Kyun;Woo, Jong-Myung
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.245-248
    • /
    • 2005
  • In this paper, small sized half-wavelength circular loop antenna which attached beneath a visor of helmet is designed and fabricated at the resonant frequency of 449MHz. To reduce the size of the antenna, double series-shorted stubs are inserted inside the loop for practical use of a vacant space of loop inside. Also, It is designed for the printed type to install the helmet easily. The size of antenna on helmet is reduced to 87.75%(diameter : 70mm, height :.36mm) compare with general type antenna(diameter : 200mm height 101mm). The return loss, -10dB bandwidth and gain are -13.2dB, 17.6MHz(3.9%), and -1.78dBd. And, radiation pattern is omni-directional pattern at H-plane. Therefore, it can be seen that the half-wavelength circular loop antenna using double series-shorted stubs is proper structure for the miniaturization and the installed antenna of the helmet.

  • PDF

Passive Mode Locking of Figure '8' Type Erbium-doped Fiber Ring Laser Using Nonlinear Loop Mirror (비선형 Loop Mirror 방식을 이용한 '8'자 고리형 Erbium 광섬유 레이저의 수동형 모드 록킹)

  • 박희갑
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.330-337
    • /
    • 1993
  • Figure '8' type, passively-mode-locked erbium-doped-fiber ring laser was developed, incorporating a nonlinear loop mirror. Transmittance of the loop mirror was found to be dependent on the incident light intensity due to the non-reciprocal nonlinear phase shift, which enables the passive mode locking of the laser. Self-starting of stable mode locking was possible with only controlling the polarization controllers inside the cavity without any help of external perturbation or modulation. The mode-locked output pulse shape was discussed in relation with the transmission characteristics of nonlinear loop mirror.

  • PDF

Effect of RFLP Marker of the Mitochondrial DNA D-Loop Region on Milk Production in Korean Cattle (한우 Mitochondrial DNA D-Loop 영역의 RFLP Marker가 산유량에 미치는 영향)

  • Chung Eui-Ryong;Chung Ku-Young
    • Food Science of Animal Resources
    • /
    • v.25 no.2
    • /
    • pp.218-225
    • /
    • 2005
  • This study was performed to determine sequence variation and RFLP of the mt DNA D-loop region using Southern blot hybridization analysis and to develop mt DNA marker affecting milk production traits in Hanwoo cows. The PCR was used to amplify an 1142 bp fragment within the D-loop region of mt DNA using specific primers. Mt DNA were digested with seven restriction enzymes and hybridized using DIG-labeled D-loop probe. The mt DNA RFLP polymorphisms were observed in the four enzymes, BamHI, RsaI, XbaI and HpaII. Nucleotide substitutions were detected at positions 441 (G/C), 469 (T/C), 503 (C/T), 569 (G/A), 614 (C/A) and 644 (C/T) of the mt DNA D-loop region between two selected lines. Significant relationship between the XbaI RFLP type and breeding value was found(p<0.05). Cows with A type had higher estimated breeding values than those with B type (P<0.05) between high and low milk production lines. Therefore, the RFLP marker of mt DNA could be used as a selection assisted tool for individuals with high milk producing ability in Hanwoo.

A Study on SAR Attenuation by Using Loop-type Ground for Mobile Handsets (루프 형태의 접지판을 이용한 휴대폰의 SAR 감쇄에 관한 연구)

  • Lee Won-Kew;Son Ji-Myoung;Han Jun-Hee;Yang Woon-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.9 s.112
    • /
    • pp.821-828
    • /
    • 2006
  • In this paper, we investigated SAR(Specific Absorption Rate) value variation by the position and size of the loop-type ground located in a test mobile handset. We carried out simulations on SAR value with loop-type grounds in rear case of a mobile handset, and obtained results showed that different positions and sizes of loop-type grounds had different SAR values. Among investigated positions and sizes of loop-type grounds, the small size case-C showed the best performance; i.e., it showed a decrease efficiency of 8.70 %. And in this case, it showed the highest induced electric-field distribution in the loop-type ground. In the simulation, the folding angle was set to $160^{\circ}$.

Phase Control Loop Design based on Second Order PLL Loop Filter for Solid Type High Q-factor Resonant Gyroscope (고체형 정밀 공진 자이로스코프를 위한 이차 PLL 루프필터 기반 위상제어루프 설계)

  • Park, Sang-Jun;Yong, Ki-Ryeok;Lee, Young-Jae;Sung, Sang-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.6
    • /
    • pp.546-554
    • /
    • 2012
  • This paper suggests a design method of an improved phase control loop for tracking resonant frequency of solid type precision resonant gyroscope. In general, a low cost MEMS gyroscope adapts the automatic gain control loops by taking a velocity feedback configuration. This control technique for controlling the resonance amplitude shows a stable performance. But in terms of resonant frequency tracking, this technique shows an unreliable performance due to phase errors because the AGC method cannot provide an active phase control capability. For the resonance control loop design of a solid type precision resonant gyroscope, this paper presents a phase domain control loop based on linear PLL (Phase Locked Loop). In particular, phase control loop is exploited using a higher order PLL loop filter by extending the first order active PI (Proportion-Integral) filter. For the verification of the proposed loop design, a hemispherical resonant gyroscope is considered. Numerical simulation result demonstrates that the control loop shows a robust performance against initial resonant frequency gap between resonator and voltage control oscillator. Also it is verified that the designed loop achieves a stable oscillation even under the initial frequency gap condition of about 25 Hz, which amounts to about 1% of the natural frequency of a conventional resonant gyroscope.