Seismic Performance of T-Shaped PC Walls with Wet Cast Joint (현장타설 습식접합부가 있는 T형 PC 벽체의 내진성능)

  • Lim, Woo-Young;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.255-266
    • /
    • 2014
  • This paper investigates the seismic performance of T-shaped PC walls with a new vertical connections and wet cast joint. The load-displacement relationship, strength, ductility, failure mechanism, and deformation capacity of the T-shaped PC walls subjected to cyclic loading are verified. Test parameter is diagonal reinforcement of both flange and web wall panels to transfer shear strength. The longitudinal reinforcing steel bars placed edges of walls yield first and the ultimate deformation is terminated due to premature failure of connections. And diagonal reinforcements for shear transfer in walls are effective to restrain the wall crack. The strength and displacement obtained by the cross section analysis were very similar to the experimental data.

Strength Prediction of Corbels Using Strut-and-Tie Model Analysis

  • Kassem, Wael
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.2
    • /
    • pp.255-266
    • /
    • 2015
  • A strut-and-tie based method intended for determining the load-carrying capacity of reinforced concrete (RC) corbels is presented in this paper. In addition to the normal strut-and-tie force equilibrium requirements, the proposed model is based on secant stiffness formulation, incorporating strain compatibility and constitutive laws of cracked RC. The proposed method evaluates the load-carrying capacity as limited by the failure modes associated with nodal crushing, yielding of the longitudinal principal reinforcement, as well as crushing or splitting of the diagonal strut. Load-carrying capacity predictions obtained from the proposed analysis method are in a better agreement with corbel test results of a comprehensive database, comprising 455 test results, compiled from the available literature, than other existing models for corbels. This method is illustrated to provide more accurate estimates of behaviour and capacity than the shear-friction based approach implemented by the ACI 318-11, the strut-and-tie provisions in different codes (American, Australian, Canadian, Eurocode and New Zealand).

Behavior of SFRC interior beam-column joints under cyclic loading

  • Khalaf, Noor Ayaad;Qissab, Musab Aied
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.3
    • /
    • pp.167-193
    • /
    • 2020
  • In this paper, the behavior of interior steel fiber reinforced concrete beam - column joints (BCJs) under cyclic loading is investigated. An experimental program including tests on twelve reinforced concrete (BCJs) specimens under cyclic loading was carried out. The test specimens are divided into two groups having different geometry: group (G1) (symmetrical BCJs specimens) and group (G2) (nonsymmetrical BCJs specimens). The parameters considered in this study are the steel fibers (SFs) content by volume of concrete (Vf), the spacing of shear reinforcement at the joint region, and the area of longitudinal flexural reinforcement. Test results show that the addition of 0.5% SFs with stirrups spacing S=Smax has effectively enhanced the overall performance of BCJs with respect to energy dissipation, ductility ratio, spreading and width of cracks. The failure of specimens is governed mainly by the formation of a plastic hinge at the face column and outside the beam-column junction. Secondary shear cracks were also observed in the beam-column junctions.

An Analytical Evaluation on the Ductility of Reinforced High-Strength Concrete Columns (고강도 콘크리트를 이용한 철근콘크리트 기둥 부재의 연성평가에 관한 연구)

  • 장일영;송재호;한상묵;박훈규
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.3
    • /
    • pp.57-66
    • /
    • 2000
  • The ductility is an important consideration in the design of reinforced concrete structures. In the seismic design of reinforced concrete columns, it is necessary to allow for relatively large ductilities that the seismic energy be absorbed without shear failure of significant strength degradation after the reinforcement yielding in columns. Therefore, prediction of the ductility should be as accurate as possible. This research investigate the ductile behavior of rectangular reinforced high-strength concrete columns like as bridge piers with confinement steel. The effects on the ductility of axial load, lateral reinforcement ratio, longitudinal reinforcement ratio, shear span ratio, and compressive strength of concrete were investigated analytically using layered section analysis. as the results, it was proposed the proper relationship between ductility and variables and formulated into equations.

Quasi Static Test of Real Scaled RC Piers with Low-Aspect Ratio (저형상비 RC교각의 실물모형 준정적실험)

  • Cho, Chang-Beck;Kwahk, Im-Jong;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.218-221
    • /
    • 2006
  • The past Korean Bridge Design Specifications have no limitation on the amount of lap splices of longitudinal bars in the plastic hinge zone of piers. A majority of bridge piers which have been non-seismically designed might have some lap splices in plastic hinge zone. Also a number of those piers in Korea have a low aspect ratio(height/section area). So, some problems such as low ductility behavior may happen. In this study, the real pier which was non-seismically designed and has a low aspect ratio was selected for the quasi-static tests. Two groups of full scaled RC pier models of which aspect ratios are about 2.26 and about 2.67 were fabricated. And then, quasi-static tests according to the drift level history method were implemented. From the test results, the failure of these test specimens have been shown in the complex shear-flexural or shear modes. The low aspect ratio and the lap splice have largely influenced on the seismic performance of bridge piers.

  • PDF

Shear Strength Enhancement of Hollow PHC Pile Reinforced with Infilled Concrete and Shear Reinforcement (내부충전 콘크리트와 전단철근을 이용한 중공 PHC말뚝의 전단보강 효과)

  • Hyun, Jung-Hwan;Bang, Jin-Wook;Lee, Seung-Soo;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.71-78
    • /
    • 2012
  • In order to improve the shear strength of conventional pre-tensioned spun high strength concrete (PHC) pile, concrete-infilled composite PHC (ICP) pile, a PHC pile reinforced by means of shear reinforcement and infilled concrete, is proposed. Two types of specimens were cast and tested according to KS (Korean Standards) to verify the shear strength enhancement of ICP pile. Based on the test results, it was found that the KS method was not suitable due to causing shear failure of ICP pile. However, shear strength enhancement was clearly verified. The obtained shear strength of the ICP pile was more than twice that of conventional PHC pile. In addition, the shear strength of ICP pile reinforced with longitudinal reinforcement was estimated to be more than 2.5 times greater than that of conventional PHC pile. The allowable shear force of ICP pile, which was determined by the allowable stress design process, indicated a large safety factor of more than 2.9 compared to the test results.

Analysis of mechanical performance of continuous steel beams with variable section bonded by a prestressed composite plate

  • Tahar Hassaine Daouadji;Rabahi Abderezak;Benferhat Rabia
    • Steel and Composite Structures
    • /
    • v.50 no.2
    • /
    • pp.183-199
    • /
    • 2024
  • In this paper, a closed-form rigorous solution for interfacial stress in continuous steel beam with variable section strengthened with bonded prestressed FRP plates and subjected to a uniformly distributed load is developed using linear elastic theory and including the variation of fiber volume fractions with a longitudinal orientation of the fibers of the FRP plates. The results show that there exists a high concentration of both shear and normal stress at the ends of the laminate, which might result in premature failure of the strengthening scheme at these locations. The theoretical predictions are compared with other existing solutions. Overall, the predictions of the different solutions agree closely with each other. A parametric study has been conducted to investigate the sensitivity of interface behavior to parameters such as laminate and adhesive stiffness, the thickness of the laminate and the fiber volume fractions where all were found to have a marked effect on the magnitude of maximum shear and normal stress in the composite member. This research gives a numerical precision in relating to the others studies which neglect the effect of prestressed plate and the shear lag impact. The physical and geometric properties of materials are taken into account, and that may play an important role in reducing the interfacial stresses magnitude.

The Strain of Transverse Steel and Concrete Shear Resistance Degradation after Yielding of Reinforced Concrete Circular Pier (철근콘크리트 원형 교각의 횡방향철근 변형률과 항복이후 콘크리트 전단저항 저감)

  • Ko, Seong Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.147-157
    • /
    • 2018
  • The basis of capacity design has been explicitly or implicitly regulated in most bridge design specifications. It is to guarantee ductile failure of entire bridge system by preventing brittle failure of pier members and any other structural members until the columns provides fully enough plastic rotation capacity. Brittle shear is regarded as a mode of failure that should be avoided in reinforced concrete bridge pier design. To provide ductility behavior of column, the one of important factors is that flexural hinge of column must be detailed to ensure adequate and dependable shear strength and deformation capacity. Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with 4.5 aspect ratio. The test variables are longitudinal steel ratio, transverse steel ratio, and axial load ratio. Eight flexurally dominated columns were tested. In all specimens, initial flexural-shear cracks occurred at 1.5% drift ratio. The multiple flexural-shear crack width and length gradually increased until the final stage. The angles of the major inclined cracks measured from the vertical column axis ranged between 42 and 48 degrees. In particular, this study focused on assessing transverse reinforcement contribution to the column shear strength. Transverse reinforcement contribution measured during test. Each three components of transverse reinforcement contribution, axial force contribution and concrete contribution were investigated and compared. It was assessed that the concrete stresses of all specimen were larger than stress limit of Korea Bridge Design Specifications.

Experimental and numerical analysis of the punching behavior of RC isolated footings

  • Walid, Mansour;Sabry, Fayed;Ali, Basha
    • Steel and Composite Structures
    • /
    • v.45 no.5
    • /
    • pp.665-682
    • /
    • 2022
  • In the current study, punching behavior of Reinforced concrete (RC) isolated footings was experimentally and numerically investigated. The experimental program consisted of four half-scale RC isolated footing specimens. The test matrix was proposed to show effect of footing area, reinforcement mesh ratio, adding internal longitudinal reinforcement bars and stirrups on the punching response of RC isolated footings. Footings area varied from 1200×1200 mm2 to 1500×1500 mm2 while the mesh reinforcement ratio was in the range from 0.36 to 0.45%. On the other hand, a 3D non-linear finite element model was constructed using ABAQUS/standard program and verified against the experimental program. The numerical results agreed well with the experimental records. The validated numerical model was used to study effect of concrete compressive strength; longitudinal reinforcement bars ratio and stirrups concentration along one or two directions on the ultimate load, deflection, stiffness and failure patterns of RC isolated footings. Results concluded that adding longitudinal reinforcement bars did not significantly affect the punching response of RC isolated footings even high steel ratios were used. On the contrary, as the stirrups ratio increased, the ultimate load of RC isolated footings increased. Footing with stirrups ratio of 1.5% had ultimate load equal to 1331 kN, 19.6% higher than the bare footing. Moreover, adding stirrups along two directions with lower ratio (0.5 and 0.7%) significantly enhanced the ultimate load of RC isolated footings compared to their counterparts with higher stirrups ratio (1.0 and 1.5%).

Analysis and design for torsion in reinforced and prestressed concrete beams

  • Rahal, Khaldoun N.
    • Structural Engineering and Mechanics
    • /
    • v.11 no.6
    • /
    • pp.575-590
    • /
    • 2001
  • This paper presents a simplified method for the design and analysis of non-prestressed, partially prestressed, and fully prestressed concrete beams subjected to pure torsion. The proposed model relates the torsional strength to the concrete compressive strength and to the amounts of transverse and longitudinal reinforcement. To check the adequacy of this simple method, the calculated strength and mode of failure are checked against the experimental results of 17 prestressed concrete 66 reinforced concrete beam tests available in the literature, and very good agreement is found. The simplicity of the method is illustrated by two examples, one for design and another for analysis.