• 제목/요약/키워드: Long-term in-situ test

검색결과 33건 처리시간 0.023초

International Joint Research for the Colloid Formation and Migration in Grimsel Test Site: Current Status and Perspectives

  • Sang-Ho Lee;Jin-Seok Kim;Bong-Ju Kim;Jae-Kwang Lee;Seung Yeop Lee;Jang-Soon Kwon
    • 방사성폐기물학회지
    • /
    • 제20권4호
    • /
    • pp.455-468
    • /
    • 2022
  • Colloid Formation and Migration (CFM) project is being carried out within the Grimsel Test Site (GTS) Phase Ⅵ. Since 2008, the Korea Atomic Energy Research Institute (KAERI) has joined CFM to investigate the behavior of colloid-facilitated radionuclide transport in a generic Underground Research Laboratory (URL). The CFM project includes a long-term in-situ test (LIT) and an in-rock bentonite erosion test (i-BET) to assess the in-situ colloid-facilitated radionuclide transport through the bentonite erosion in the natural flow field. In the LIT experiment, radionuclide-containing compacted bentonite was equipped with a triple-packer system and then positioned at the borehole in the shear zone. It was observed that colloid transport was limited owing to the low swelling pressure and low hydraulic conductivity. Therefore, a postmortem analysis is being conducted to estimate the partial migration and diffusion of radionuclides. The i-BET experiment, that focuses more on bentonite erosion, was newly designed to assess colloid formation in another flow field. The i-BET experiment started with the placement of compacted bentonite rings in the double-packer system, and the hydraulic parameters and bentonite erosion have been monitored since December 2018.

생물학적 통풍법 공정관리를 위한 원위치 토양가스 관측정 개발 (Development of In-Situ Soil Gas Monitoring Well for Managing the Bioventing Performance)

  • 유찬
    • 한국농공학회논문집
    • /
    • 제49권1호
    • /
    • pp.67-76
    • /
    • 2007
  • Bioventing is commonly used for petroleum hydrocarbon (PHC) spills. This process provides better subsurface oxygenation, thus stimulating degradation by indigenous microorganisms. Therefore soil vapor monitoring points (VMPs) are extremely important in determining the potential effectiveness of bioventing and in long-term monitoring of bioventing progress. In this study in-situ soil gas monitoring well (GMW) was developed and presented the pilot test results which recover the contaminated site by bioventing method. The result of application was successful and it was expected that GMW developed could be applied to the evaluation procedure of bioventing effectiveness and long-term remediation potential.

An Electrochemical Method to Predict Corrosion Rates in Soils

  • Dafter, M.R
    • Corrosion Science and Technology
    • /
    • 제15권5호
    • /
    • pp.217-225
    • /
    • 2016
  • Linear polarization resistance (LPR) testing of soils has been used extensively by a number of water utilities across Australia for many years now to determine the condition of buried ferrous water mains. The LPR test itself is a relatively simple, inexpensive test that serves as a substitute for actual exhumation and physical inspection of buried water mains to determine corrosion losses. LPR testing results (and the corresponding pit depth estimates) in combination with proprietary pipe failure algorithms can provideauseful predictive tool in determiningthe current and future conditions of an asset. Anumber of LPR tests have been developed on soil by various researchers over the years1), but few have gained widespread commercial use, partly due to the difficulty in replicating the results. This author developed an electrochemical cell that was suitable for LPR soil testing and utilized this cell to test a series of soil samples obtained through an extensive program of field exhumations. The objective of this testing was to examine the relationship between short-term electrochemical testing and long-term in-situ corrosion of buried water mains, utilizing an LPR test that could be robustly replicated. Forty-one soil samples and related corrosion data were obtained from ad hoc condition assessments of buried water mains located throughout the Hunter region of New South Wales, Australia. Each sample was subjected to the electrochemical test developed by the author, and the resulting polarization data were compared with long-term pitting data obtained from each water main. The results of this testing program enabled the author to undertake a comprehensive review of the LPR technique as it is applied to soils and to examine whether correlations can be made between LPR testing results and long-term field corrosion.

도로기초에서 교통 및 환경하중에 의한 비선형 현장 응력 거동 평가 (Evaluation of Traffic Load and Moisture-Induced Nonlinear In-Situ Stress on Pavement Foundation Layers)

  • 박성완;황규영;안동석;정문경;서영국
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.11-16
    • /
    • 2009
  • Better understanding of in-situ mechanical behavior of pavement foundations is very important to predict long-term effects on the system performance of transport infrastructure. In order to do that, resilient stiffness characterization of geomaterals is needed to properly adopt such mechanistic analysis under both traffic and environmental loadings. In this paper, in situ monitoring data from KHC test road was used to analyze the non-linearity of stress conditions under traffic and moisture loadings. Then, the predicted non-linear response using finite element method with a selected constitutive model of foundation geomaterials are verified with the field data.

  • PDF

매립지반에 적용된 쇄석말뚝의 보강효과 (The Reinforcement Effect of Stone Columns on Refuse Landfill)

  • 이봉직;배우석;이준대
    • 한국안전학회지
    • /
    • 제15권2호
    • /
    • pp.97-102
    • /
    • 2000
  • This paper presents the design, construction and performance of ground treatment to support road embankment on refuse landfill. Long-term settlement of refuse landfill is analysised by Sower and Yen/scanlon. As a results of site test, predicting settlement excess the allowable settlement and ultimate bearing capacity is not satisfied. The effectiveness of DDR(Deep Dynamic Replacement) is monitered by field tests (SPT, PBT, PMT) before, during and after construction of the stone columns. The ultimate bearing capacity for reinforced landfill by stone columns obtained from the in-situ test results has been compared with the existing theories. In municipal wastes landfill, settlement after treatment using stone column is satisfied to allowable residual settlement. Therefore, long-term stability can be gain in these cases.

  • PDF

Influence of post-pouring joint on long-term performance of steel-concrete composite beam

  • Huang, Dunwen;Wei, Jun;Liu, Xiaochun;Zhang, Shizhuo;Chen, Tao
    • Steel and Composite Structures
    • /
    • 제28권1호
    • /
    • pp.39-49
    • /
    • 2018
  • The concrete bridge decks are usually precast and in-situ assembled with steel girders with post-pouring joint in the construction practice of super-wide steel-concrete composite beam. But the difference of concrete age between the precast slabs and the post-pouring joint has been not yet considered for the long-term performance analysis of this kind composite beam. A simply supported precast-assembled T-shaped beam was taken as an example to analyze the long-term performance of steel-concrete composite beam with post-pouring joint. Based on the deformation coordination conditions of the old-new concrete deck and steel girder, a theoretical model for the long-term behavior of precast-assembled composite beam is proposed in this paper according to age-adjusted effective modulus method. Then, the feasibility of the proposed model is verified by the available test data from the Gilbert's composite beams. Parametric studies were preformed to evaluate the influences of the cross-sectional area ratio of the post-pouring joint to the whole bridge deck, as well as the difference of concrete age between the precast slabs and the post-pouring joint, on the long-term performance of the composite beam. The results indicate that the traditional method without considering the age difference would seriously underestimate the effect of creep and shrinkage of concrete bridge decks. The concrete age difference between the precast slabs and the post-pouring joint should be demonstrated for the life cycle design and long-term performance analysis of precast-assembled steel-concrete composite beams.

도로기초에서 교통 및 환경하중에 의한 비선형 현장응력 평가 (Evaluation of Traffic Load and Moisture-Induced Nonlinear In-situ Stress on Pavement Foundation Layers)

  • 박성완;황규영;정문경;서영국
    • 한국지반공학회논문집
    • /
    • 제25권7호
    • /
    • pp.47-54
    • /
    • 2009
  • 도로하부에 대한 현장에서의 역학적인 거동에 대한 이해는 교통기반시스템의 장기공용성을 예측하는데 매우 중요하다. 이러한 현장거동에서 지반재료에 대한 회복변형 거동 정량화는 교통하중과 환경조건을 고려한 역학적인 해석이 필수적이다. 따라서 본 논문에서는 한국도로공사 시험도로에서 현장자료의 계측과 분석을 통하여 선택된 도로하부 입상재료에 대한 구성방정식을 활용한 비선형 재료거동과 응력을 예측 분석하고 이를 현장자료와 비교하고 검증하였다.

해안 도시폐기물 매립지의 침출수 이동 특성 및 부식성 (The characteristics of leachate migration and corrosivity in municipal wastefills at seaside)

  • 장연수;정하익;김진만
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1992년도 폐기물 매립지의 공학적 특성과 개량기술
    • /
    • pp.33-66
    • /
    • 1992
  • Recently, waste landfills built on seashores have been increased because of the easy availability of broad area near the urban communities. To evaluate the performance of the marine clay landfill liner numerical contaminant transport analyses are performed by selecting the typical section of a waste landfill built on seashores and using hydraulic conductivity data obtained from the site. Also, the laboratory electrical resistivity test and the in-situ corrosion test are performed in order to analyze the influence of the soil and leachates composing the landfills on the construct ion materials. From the results of contaminant transport analyses, it is shown that the leachates can be migrated faster through narrow pervious channels than the wide homogeneous pervious tedium and the importance of good quality barriers to prevent the contaminant migration is recognized. In the laboratory electrical resistivity test all the earth materials except the cover soils saturated with distilled water have small resistivities, which shows a high potential of corrosivity of soils composing landfills. However, the degree of corrosion of specimens buried in the landfills was not so severe except the zinc and carbon steel specimens. This apparently conflict results present the necessity of the investigation of other major factors and the long term in-situ corrosion test.

  • PDF

Mechanical behavior of an underground research facility in Korea Atomic Energy Research Institute

  • Kwon S.K.;Cho W.J.;Hahn P.S.
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 Proceedings of The 6th korea-china joint workshop on nuclear waste management
    • /
    • pp.245-252
    • /
    • 2005
  • An underground research facility (KURF) is under construction at KAERI for the in situ studies related to the validation of a HLW disposal system. For the safe construction and long-term researches at KURF, mechanical stability of the facility should be evaluated. In this study, 3D mechanical stability analysis using the rock mass properties determined from various in situ as well as laboratory tests was carried out. From the analysis, it was possible to predict the rock deformation, stress concentration, and plastic zone developed before and after the excavation. A test blasting was performed to characterize the site dependent dynamic response, which can be used for the prediction of the blasting impact on the facilities in KAERI.

  • PDF

Long-term Testing and Analysis of a ScSZ/LaSrCuFe Cell

  • Wackerl, Jurgen;Peck, Dong-Hyun;Markus, Torsten
    • 한국세라믹학회지
    • /
    • 제45권12호
    • /
    • pp.788-795
    • /
    • 2008
  • An electrolyte supported SOFC cell was tested at $800^{\circ}C$ in air for 3600 h with an applied current density of $200\;mA/cm^2$ to examine possible cathode degradation issues. A scandium- stabilized zirconia (ScSZ) with additional manganese doping (ScSZ: Mn) was used as electrolyte. A strontium and copper-doped lanthanum ferrite (LaSrCuFe) and platinum were used as cathode and quasi-anode material, respectively. The DC resistance was logged over the complete testing period. Additionally, impedance spectroscopy was used from time to time to track changes of the cell in-situ. Post-test analysis of the cell using methods like scanning electron microscopy imaging and other electrochemical testing methods allow the identification of different degradation sources. The results indicate a promising combination of electrolyte and cathode material in terms of chemical compatibility and electrical performance.