• 제목/요약/키워드: Long-life characteristic

검색결과 161건 처리시간 0.056초

장수명 공동주택의 가변성 확보를 위한 벽체 인터페이스 유형화 연구 (A Study on the Categorization of Interface for the Flexibility in the Wall System of Long Life Housing)

  • 박요한;최영호;김성완
    • KIEAE Journal
    • /
    • 제8권3호
    • /
    • pp.37-42
    • /
    • 2008
  • The purpose of this study was to comprehend specific characteristic of interface and present the standardized interface of Long Life Housing, which could be obtained by the total and various approaches. With this in mind we analyzed related studies of interface through previous studies, and based on the analysis we created standardized factors of categorization in view of characteristic of interface. Using these factors, we can determine whether the interface could be used systematically in Long Life Housing. And as these were presented in the form of Key Map for expedite the synthetic understanding of interface, we could easily reconize types of interface. Especially, we only dealt the wall of flexible interface of Long Life Housing. Throughout systemizing and standardizing works, we can expedite the understanding of interface of Long Life Housing and finally, we want to make basic data used for date base of interface which can be available for Long Life Housing.

LED조명제품의 수명시험 연구 (Investigation on the Life Test of LED Lighting Module)

  • 서정남;여인선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1491-1492
    • /
    • 2008
  • This paper investigates life test of LED lighting module using accelerated life test method. Pooly designed LED lighting systems can experience a short life. By knowing the relationship between life and heat, LED system manufacturers can design and build long-lasting systems. In this study, various white LED from several other manufacturer were subjected to life tests at LED lated temperatures for prediction to life of LED lighting systems. Results show that the different LED products have various optical characteristic and different life values.

  • PDF

수명예측 방법에 따른 계전기의 수명분석 (Life Analysis of Relays based on Life Prediction Method)

  • 신건영;이덕규;이희성
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.115-120
    • /
    • 2012
  • In order to establish preventive maintenance standards through analysis & reliability prediction of about 60,000pcs of 20kindsof relays and contractors used for Seoul subway trains, several life prediction methodologies were applied. Firstly, Occurrence, Severity, Detection were defined and predicted by applying operation characteristic of EMU to the number of actions of relays & contactors which the manufacturers generally offer as the life cycle data. Secondly, failure distribution and average life of parts were analyzed through interpretation of field data based on a lot of experience which had built up in the field for a long time. Finally, using the 217PLUS standard as a reliability prediction program, comparative analysis of use reliability and inherent reliability was done through reliability prediction at the part level and system level.

해상풍력 구조물 설계를 위한 풍황 특성분석 (Analysis on wind condition characteristics for an offshore structure design)

  • 서현수;경남호;;김현구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.262-267
    • /
    • 2008
  • The long-term wind data are reconstructed from the short-term meteorological data to design the 4 MW offshore wind park which will be constructed at Woljeong-ri, Jeju island, Korea. Using two MCP (Measure-Correlate-Predict) models, the relative deviation of wind speed and direction from two neighboring reference weather stations can be regressed at each azimuth sector. The validation of the present method is checked about linear and matrix MCP models for the sets of measured data, and the characteristic wind turbulence is estimated from the ninety-percent percentile of standard deviation in the probability distribution. Using the Gumbel's model, the extreme wind speed of fifty-year return period is predicted by the reconstructed long-term data. The predicted results of this analysis concerning turbulence intensity and extreme wind speed are used for the calculation of fatigue life and extreme load in the design procedure of wind turbine structures at offshore wind farms.

  • PDF

Nb/Ni Clad 전극을 이용한 고효율 CCFL 개발 (Development of CCFL with Nb/Ni Gad Electrode for high efficiency)

  • 박기덕;양승수;박두성;김서윤;임영진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.441-443
    • /
    • 2005
  • According as CCFL(Cold Cathode Fluorescent lamp) of light source in Backlight unit for Note PC (Personal computer) is presently needed to low power consumption and long life time, the development focus of CCFL is going on the discharge gas, phosphor and electrode material. First of all, discharge voltage characteristic of CCFL is closely connected with electrode material For low discharge voltage, the characteristic of electrode material is needed to low work function, low sputtering ratio and superior manufacturing property. We developed new CCFL with Nb/Ni Clad electrode superior to conventional CCFL. Because Nb/Ni Clad electrode with Ni material and Nb material, the electrical characteristic is superior to other electrode materials. The electrode of Nb/Ni Clad is composed that Ni of outside material has superior manufacturing property and Nb of inside material has low work function. Nb/Ni Clad of new electrode material is made by process of Rolling mill at high pressure and heat treatment. We compared electrical characteristic of Nb/Ni clad electrode with conventional Mo electrode by measurement. Mo electrode and Nb/Ni Clad electrode of cup type with diameter 1.1 mm and length 3.0mm are used to this experiment. Material content of Mo electrode is Mo 100%. But, Nb/Ni Clad electrode is composed by content of Nb 40% and Ni 60%. The result of comparison measurement between new CCFL with Nb/Ni Clad electrode and conventional CCFL was appeared that CCFL with Nb/Ni Clad electrode had superior characteristic than conventional CCFL. As a result of experiment, we completed Note PC with low power consumption and long life time by application of new CCFL with Nb/Ni Clad electrode.

  • PDF

주택성능등급 가변성 세부성능 항목의 특성 및 개선방안 (The Characteristic and Improvement of Flexibility Performance Item evaluated by "Housing Performance Grading System")

  • 이성옥
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.29-35
    • /
    • 2011
  • This study aims to suggest improvement plans and explain about the current situation for facilitating Long-life housing, based on the results on flexibility items among 27 items consisting the "Housing Performance Grading System". From the 9th of January, 2006 to the month of July in 2011, study has analyzed evaluation results on 216 different types for each grade and reviewed evaluation criteria and methods. Current evaluation criteria applies quantitative analysis, by calculating in percentage how much bearing walls and columns, which hinder flexibility, take up space in the household. The evaluation rate for each household was assessed in relation to its structural system, and a higher grade was given to column-typed structures. In addition, to facilitate long-life housing, this study extracted harmful factors, expanding the range of evaluation. The first step was to evaluate structure, which is the basic element. The second step can to evaluate the probability of applying resources in response to the changes of structural systems. As The third step, Flexibility item will evaluate the probability of moving the water-using area, suggesting gradual approach. Thus, through evaluations of flexibility items, the study aims to improve the quality of life in household, by avoiding uniform structures and acquiring more freedom for space designs.

베어링강의 기가사이클 피로 특성에 관한 연구 (Fatigue Characteristic of Bearing Steel(STB2) in Gigacycle)

  • 김상천;서창민;황병원;이태성
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.370-375
    • /
    • 2004
  • Fatigue tests were carried out to find the fatigue characteristics in the super-long life range by using a cantilever type rotational bending fatigue test machine. Three kinds of specimen in bearing steels with the quenched and tempered in air (A and B, B: shot peened after heal treatment) and under vacuum conditions(C:non-shot peened)were tested in this study. S-N curves obtained from fatigue tests of C specimen tend to come dawn again in the super-long life range due to fish-eye type cracking, while most of A and B specimens fractured by surface defects such as scratches and slip lines. This duplex S-N behavior for the high strength steels have to be reviewed by the change of fracture modes.

  • PDF

독립헝 태양광 발전 시스템의 제어 알고리즘에 관한 연구 (The Study of Control Algorithm for Stand alone PV System)

  • 김태엽;정맹화;고권성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1382-1384
    • /
    • 2002
  • The flooded type battery is used for solar lighting system. Because the characteristic of flooded type battery is the short life time, the maintenance cost is high. So the using flooded type battery in this system is inappropriate. The valve regulated lead acid batter.(VRLA) is the maintenance free and cycle service purpose. This paper presents the development of control system and monitoring system to applied VRLA battery for maintenance free and long life time in system.

  • PDF

Epoxy/EPDM 거시계면의 최적조건과 V-t 특성 (Optimal Pressure Condition and V-t Characteristic of Macro Interface between Epoxy and EPDM)

  • 박우현;이동규;이상극;안준호;김충혁;이기식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.439-442
    • /
    • 2002
  • The interface between two different materials in the insulation systems is the weak-link in the underground power transmission systems, In this paper, Optimum conditions of the interface between Epoxy and EPDM is studied. The variation factor condition of interface is roughness of surface, spreading of oils, interfacial pressure and temperature. The breakdown times under the constant voltage below the breakdown voltage were also gained. The breakdown voltage at the after laying time equivalent to is calculated by the V-t characteristic and the inverse power law. When this is done, the characteristic life exponent n is used and the long time breakdown voltage can be evaluated.

  • PDF