An Experimental Comparison of Strain Measurement Sensors in Long-Term Monitoring Systems (장기 계측 시스템의 변형률 측정 센서에 대한 실험적 비교)

  • Jung, Hie-Young;Lee, Chang-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.191-199
    • /
    • 2000
  • Since a few decade ago, there has been a demand on the safety monitoring of civil infrastructures, such as bridges, in order to prevent possibly occurrable disaster due to human negligence. The main cause for a failure or collapse of structures is absolutely a structural crack. For the reason, it is necessary to monitor the propagation of a structural crack. But a crack in bridges is gradually propagating with the traffic loads through the long term. There are lots of sensors to monitor structural cracks on bridges, but much information about them was not given so far. Therefore, in this study, the experimental comparison for long-term monitoring sensors, especially, strain measurement sensors, in terms of duration, temperature dependency, accuracy was made extensively.

  • PDF

A Study on the Status of Drug Use among Elderly Residents in Long-Term Care Facility (장기요양기관 입원 노인의 약물 사용 현황 및 관련 요인)

  • Jeon, Mi Yang;Lee, Yong Sook;Lim, Jeong Ok;Seol, Ju Yeong;Kim, Ju Yeong;Kim, Yeon
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.3
    • /
    • pp.244-250
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate medication and related factors including: gender, age, duration of hospitalization, MMSE, and ADL in elderly who were hospitalized in long-term care facilities. Methods: A total of 282 elderly people who were hospitalized for more than a month were asked to fill in a structured questionnaire which was used to collect data regarding their gender, age, duration of hospitalization, MMSE, ADL, and medication. Results: The average number of drugs per patient was 7.50. Subjects taking 6-7 medications were the highest ranking (23.7%). According to multiple regression analysis, the most significant factor relating to the number of drugs prescribed for each subject were the ages of the subjects (p=.007). Conclusion: We found that the number of prescribed drugs taken by those who were hospitalized were related to age. A tailored strategy is needed to decrease the number of drugs according to age and to control the medicines prescribed to the elderly who are hospitalized in long-term care facilities.

Development and Testing of a Prototype Long Pulse Ion Source for the KSTAR Neutral Beam System

  • Chang Doo-Hee;Oh Byung-Hoon;Seo Chang-Seog
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.357-363
    • /
    • 2004
  • A prototype long pulse ion source was developed, and the beam extraction experiments of the ion source were carried out at the Neutral Beam Test Stand (NBTS) of the Korea Superconducting Tokamak Advanced Research (KSTAR). The ion source consists of a magnetic bucket plasma generator, with multi-pole cusp fields, and a set of tetrode accelerators with circular apertures. Design requirements for the ion source were a 120kV/65A deuterium beam and a 300 s pulse length. Arc discharges of the plasma generator were controlled by using the emission-limited mode, in turn controlled by the applied heating voltage of the cathode filaments. Stable and efficient arc plasmas with a maximum arc power of 100 kW were produced using the constant power mode operation of an arc power supply. A maximum ion density of $8.3{\times}10^{11}\;cm^{-3}$ was obtained by using electrostatic probes, and an optimum arc efficiency of 0.46 A/kW was estimated. The accelerating and decelerating voltages were applied repeatedly, using the re-triggering mode operation of the high voltage switches during a beam pulse, when beam disruptions occurred. The decelerating voltage was always applied prior to the accelerating voltage, to suppress effectively the back-streaming electrons produced at the time of an initial beam formation, by the pre-programmed fast-switch control system. A maximum beam power of 0.9 MW (i.e. $70\;kV{\times}12.5\;A$) with hydrogen was measured for a pulse duration of 0.8 s. Optimum beam perveance, deduced from the ratio of the gradient grid current to the total beam current, was $0.7\;{\mu}perv$. Stable beams for a long pulse duration of $5{\sim}10\;s$ were tested at low accelerating voltages.

Estimating long-term sustainability of real-time issues on portal sites (포털사이트 실시간이슈 지속가능성 평가)

  • Chong, Min-Young
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.255-260
    • /
    • 2019
  • Real-time search keywords are not only limited to search keywords that are rapidly increasing interest in real-time, but also have a limitation that they are difficult to determine the sustainability as there is a difference in ranking between portal sites. Estimating sustainability for real-time search keywords is significant in terms of overcoming these limitations and providing some predictability. In particular, long-term search keywords that last for more than a month are of high value as long-lasting social issues. Therefore, in this paper, we analyze the interest based on the ranking of the real-time search keywords and the duration based on sustained weeks, days and hours of real-time search keywords by each portal site and the integrated portal site, and then estimating sustainability based on high level of interest and duration, and present a method to derive real-time search issues with high long-term sustainability.

Retention and Occlusal Stability in Orthdontics (교정치료후 유지와 안전성에 대한 고찰)

  • Tae, Gi-Chul
    • The Journal of the Korean dental association
    • /
    • v.37 no.4 s.359
    • /
    • pp.287-293
    • /
    • 1999
  • Long-term posttreatment stability is great concern to all orthodontist. So, this article was disussed that etiology of relapse, classificatioan of retention, duration of retention and treat after relapse. The most important thing about stability was considered that growth pattern, periodontal remodeling, neuromuscular factors and applied the appropriate mechanotherapy. Retenton was considered during the treatment planning and required considerable analytic thought.

  • PDF

Adaptive Usage Parameter Control Mechanism using a Variable Token Pool in ATM Networks (ATM망에서 가변 토큰풀을 이용한 적응적 사용 파라메터 제어 메카니즘)

  • Koo, Ja-Gwang;Lee, Hwan-Chung;Kim, Chong-Gun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.9
    • /
    • pp.2366-2377
    • /
    • 1997
  • An Adaptive Usage Parameter Control(UPC) mechanism using a Variable Token Pool(VTP) which is kind of preventive traffic control in the Asynchronous Transfer Mode(ATM) networks is described. The VTP mechanism can monitor violations of the average bit rate and burst duration as well as peak bit rate for the ON-OFF type traffic. The VTP can vary the token pool size by monitoring burst duration and silence duration for a long term. It also improves the sensitivity against the violation of burst duration and average bit rate and enables to response for the violating traffic situation quickly. The variable token pool size is varied in step size by every burst duration and silence duration. Two important parameters for controlling token pool size are Down_size and Up_size. We compare the performance of LB and JW mechanism with the proposed VTP mechanism by computer simulations. We have known that the proposed method is more effective than the previous mechanisms. It is shown that the cell loss rate of the VTP quite depends on the value of Down_size and Up_size. The two parameters should be decided as a propr value according to traffic situations.

  • PDF

Characterization of sounds produced by 3 sciaenid species (민어과 어류의 명음에 관한 음향학적 특성)

  • Lee, Kyoung-Hoon;Yang, Yong-Soo;Kim, Jin-Ku;An, Heui-Chun;Shin, Jong-Keun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.3
    • /
    • pp.206-211
    • /
    • 2007
  • The sciaenid species, which has swimbladder, generates sounds by vibrating in its length wards when spawning or getting stimulus from something else. This research analyzed on sound frequency characteristics relatives to their swimbladder length of three sciaenid species, yellow croaker(Larimichthys polyactis), brown croaker(Miichthys miiuy), and white flower croaker(Nibea albiflora). As results, the dominant frequency for yellow croaker ranged over 38.08 to 141.60Hz in wide frequency band, and the averaged pulse duration expressed in $280.3{\pm}156.0ms$. For brown croaker, the dominant frequency ranged in 49.80 to 59.57Hz, and the averaged pulse duration was $129.1{\pm}36.9ms$. Moreover, the dominant frequency of white flower croaker ranged in 73.24 to 86.91Hz, and the averaged pulse duration was $88.0{\pm}15.9ms$, it has shorter pulse duration than any two species. Therefore, the dominant frequency relatives to swimbladder length of sciaenidae showed that it had widely resonant characteristics and long pulse duration as in shorter swimbladder length. Additionally, for white flower croaker, we could confirm their behavior and sounds in response to production of recorded sounds using underwater speaker.

Regional Division According to the Annual Change of Sunshine Duration in Korea (일조시간의 연변화에 따른 한국의 지역구분)

  • 문영수
    • Journal of Environmental Science International
    • /
    • v.5 no.3
    • /
    • pp.253-263
    • /
    • 1996
  • This study is an attempt to classify climatic regions of Korea based on the data of sunshine duration and to clarify the characteristics of sunshine for each divided regions. The data used in this study are the mean values of monthly and ten-daily sunshine duration, sunshine percentage, solar radiation and proud amount obtained from 63 weather stations of the Korea Meteorological Administration during the period of 1974~ 1993. The characteristics of annual change of sunshine percentage, annual duration of sunshine, percentage of sunshine, annual radiation, amount of cloud, days of sunshine percentage above 80% and-days of sunless are investigated by the mean values of -the stations belong to divided regions. The ward method of hierarchical cluster analysis is adopted to the analysis of data for the regional division. The results obtained in this study are summarized as follows. (1) The sunshine regions of Korea can be divided into six regions of the central west, central east, south west, souls east, Ullung-do and Cheju-do. These are strongly affected by the dirtribution of inclined slopes taking account of the topographic characteristics of Korea. (2) Annual distribution shows the sunshine duration of 1777~ 2287 hours, sunshine percentage of 40~53%, solar radiation of 3469~4637 MJ/$m^2$, cloud amount of 5.0~6.1, days of sunshine perrentage above 80% of 53~116days and sunless days of 46~71days. (3) The types of annual change of sunshine percentages is classified with four types of minimum in July and maximum in October, minimum in July and maximum in December, high in May and October and low in July and January, high in May and November and low in June and January. (4) The long-term trend of sunshine duration decrease in peninsula area but increase in island area and the Tong-term inclination of cloud amount is almost zero. The author believe this tendency is related to a pollutional turbidity than a cloud amount in inland area.

  • PDF