• Title/Summary/Keyword: Long pulse

Search Result 443, Processing Time 0.029 seconds

A study on the programming and erasing chracteristics of single-poly EEPROM (Single-poly EEPROM의 프로그램 및 소거특성에 관한 연구)

  • 류영철;유종근;이광엽;김영석;박종태
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.425-428
    • /
    • 1998
  • In this work, single-poly EEPROM has been designed and fabricated by using standard 0.8.mu.m CMOS process. The initial threshold voltage was aobut 0.8V but it increased ot about 6.5V after programming at Vds=11.5V and Vcg=6.5V. After erasing devices at Vs=14.2V, the threshold voltage decreased to about 1.5V. The programming time and erasing trime wree about 6ms. and 100ms. respectively. The erasing time can be reduced by applying a series of shorter erase pulse s instead of a long single erase pulse.

  • PDF

Study on Basic Magnetic Characteristics in New Magnetic Materials(2) - Magnetic Properties of Amorphous $Fe_{80}B_{15}Si_{5}$ alloy Measures with Pulse Method (새 자성재료의 기초자기특성 연구(2) - 펄스측정법에 의한 비정질 $Fe_{80}B_{15}Si_{5}$ 합금의 자기특성)

  • 이용호;신용돌;김인수;이연숙;노태환;강일구
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.42-48
    • /
    • 1991
  • The basic soft magnetic characteristics of a typical Fe based amorphous $Fe_{80}B_{15}Si_{5}$ alloy were measured with pulse metheod. Quantitative relations between magnetostriction, anisotropy energy, reluctivity were investigated. The relative contribution factor of magnetostrictive and uniaxial anisotropy energy to the reluctivity were calculated. The internal stress and induced anisotropy were estimated. A tension applied to the long axis of the sample greatly enhanced induced anisotropy.

  • PDF

On the Analysis of Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant with State-space Model and Impulse Testing (상태공간 모델과 임펄스 시험에 의한 발전소 배관지지용 유압완충기의 동특성 해석)

  • Lee, Jae-Cheon;Im, Mun-Hyeok;Hwang, Tae-Yeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.130-138
    • /
    • 2002
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state-space model of 14th order to describe the dynamics of the snubber was established by Simulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absorbers against the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which temporarily lock the control valves up, however maintain same steady-state pressures of all internal chambers in the long run. Two case studies for the analysis of the snubber were addressed. Practical pulse testing method was also proposed to identify the frequency response characteristics of the snubber.

A Speech Coder using the Simplified Multi-mode Method (단순화된 다중 모드 방법을 이용한 음성 부호화기)

  • 강홍구
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.146-149
    • /
    • 1995
  • This paper proposes a SM-CELP speech coder which applies different excitation signal according to the characteristic of speech segment at bit-rate below 4 kbps. Speech signal is divided with 2 modes such as stationary voice and etc. using the parameters of average energy of the short-time speech and the residual signal after long term prediction. Structured multi-pulse method is used for the excitation of mode-A and gaussian or pulse-like codebook for mode-B. 4.8kbps DoD-CELP are used to evaluate the performance of the proposed coder. As a result, the propose method shows 1~2 dB higher segmental signal to noise ratio and better subjectional quality without increasing the computational amount.

  • PDF

Pulsed-Power System for Leachate Treatment Applications

  • Jang, Sung-Roc;Ryoo, Hong-Je;Ok, Seung-Bok
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.612-619
    • /
    • 2011
  • This paper presents a water treatment system for leachate from sewage-filled ground that uses a pulsed-power modulator developed based on semiconductor switches in order to realize a long life, a high repetition rate, and a fast rising time. The specifications of the developed pulsed-power modulator are the pulsed output voltage, the output current, the pulse repetition rate (PRR), the pulse width, and an average output power of $60\;kV_{max}$, $300\;A_{max}$, 3000, $50\;{\mu}s$, and 15 kW, respectively. The pulsed-power water treatment system was introduced and analyzed using an equivalent electrical circuit model to optimize the output voltage waveform. The experimental results verify that the proposed water treatment system can be effectively used for industrial applications.

Method Generating Circular Wave for Synthetic Focusing (초음파 영상 시스템의 Synthetic Focusing을 위한 구면파 발생 방법)

  • Oh, J.S.;Kim, J.J.;Song, T.K.;Ahn, Y.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.215-216
    • /
    • 1998
  • The ultrasonic imaging systems using synthetic aperture beamforming has been formed in the way that one element transmits and then receives a pulse. Because the amplitude of a pulse from one element is too small to propagate a long distance, the SNR(Signal to Noise Ratio)is low. This paper proposes the method to make a circular wave almost equal to one generated by one element using several elements. The amplitude of the wave made up of several elements is much larger than that of one element. And we can improve the SNR.

  • PDF

A Study of physical energy and electrical property of carbon films synthesiszed by pulse DC magnetron sputtering parameter (펄스 DC 마그네트론 스퍼터링으로 합성된 카본 박막의 전도성과 물리적 에너지와의 상관관계에 대한 고찰)

  • Piao, Jinxiang;Wen, Long;Jin, Su-Bong;Sahu, B.B.;Han, Jeon-Geon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.34-35
    • /
    • 2014
  • 탄소는 부식되지 않고 친환경적이며 물리화학적 안정성 및 내마모성 등 많은 장점을 가지고 있어 많은 연구들이 진행 되고 있다. 하지만 탄소 박막은 전도도가 낮은 단점을 가지고 있다. 본 연구에서는 탄소 박막의 전도성과 플라즈마 변수와의 상관관계를 규명 하고자 하였다. 박막의 특성은 X-ray Diffraction (XRD), Hall measurement, Contact angle, Raman spectroscopy 등의 분석기기를 사용하여 측정하였고 그 결과 DC보다 Pulse DC를 사용할 때 더 좋은 전기적 특성을 나타내었다.

  • PDF

On the Analysis of Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant with State-space Model and Impulse Testing (상태공간 모델과 임펄스 시험에 의한 발전소 배관지지용 유압완충기의 동특성 해석)

  • Lee, Jae-Cheon;Hwang, Tae-Yeong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.89-99
    • /
    • 2001
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state-space model of 14th order to describe the dynamics of the snubber was established by Simulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absolvers against the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which temporarily lock the control valves up, however maintain same steady-state pressures of all internal chambers in the long run. Two case studies for the analysis of the snubber are addressed. Practical pulse testing method was also proposed to identify the frequency response of the snubber.

  • PDF

Design of Robust Current Controller Using GA for Three Level 24-Pulse VSC Based STATCOM

  • Janaki, M.;Thirumalaivasan, R.;Prabhu, Nagesh
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.375-380
    • /
    • 2011
  • A STATic synchronous COMpensator (STATCOM) is a shunt connected voltage source converter (VSC) based FACTS controller using Gate Turn Off (GTO) power semiconductor devices employed for reactive power control. The operation principal is similar to that of a synchronous condenser. A typical application of a STATCOM is voltage regulation at the midpoint of a long transmission line for the enhancement of power transfer capability and/or reactive power control at the load centre. This paper presents the modeling of STATCOM with twenty four pulse three level VSC and Type-1 controller to regulate the reactive current or the bus voltage. The performance is evaluated by transient simulation. It is observed that, the STATCOM shows excellent transient response to step change in the reactive current reference. While the eigenvalue analysis is based on D-Q model, the transient simulation is based on both D-Q and 3 phase models of STATCOM (which considers switching action of VSC).

Stability characteristics of DyBCO coated conductor stabilized with stainless steel

  • Dixit, Manglesh;Kim, Tae-Hyung;Oh, Sang-Soo;Song, Kyu-Jeong;Kim, Ho-Min;Park, Kwon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.288-289
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. We have experimentally studied the dependence of quench and recovery characteristics of coated conductors on the amplitude of current and duration time. The sample used in the present study is stabilized with stainless steel. Stability tests of 3 cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100 ms, with amplitude up to ~ 6 times of the critical current. The transport current that follows before and after the current pulse was fixed about ~85% the critical current. We analyzed the quench recovery using the current voltage characteristic.

  • PDF