• Title/Summary/Keyword: Long Fiber

Search Result 1,011, Processing Time 0.029 seconds

Flexure Toughness of Fiber Reinforced Concrete with Ring Type Steel Fiber (원형 강섬유 보강 콘크리트의 인성)

  • Hur, Jun;Jeong, Eui-Jeong;Choi, Oan-Chul;An, Jung-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.313-318
    • /
    • 1999
  • This study is aim to evaluate of the flexure toughness of fiber reinforced concrete with ring type steel fiber. The experiment proceeding ASTM C 78 is performed to make a comparision between the ring type flber and the double-hook type fiber which is recently come in to use. The size of the test specimen is 10$\times$10$\times$35mm and the flexture test is proceeded by third-point loading method. The test lasts until 2mm deflection and the loading speed is 0.01mm/min by deflection control. From the experimental results, the specimens with ring type fiber of 30kg/㎥ and 30mm diameter of ring circle show much higher toughness indices than those of the double-hook type fiber of 30kg/㎥ and 30mm long.

  • PDF

The Effect of Compression Molding with Inclined Force for Fiber - Reinforced Thermoplastics (섬유강화 플라스틱 복합판의 압축성형에 있어서 경사하중의 영향 (AL망의 적층소재의 유동에 의하여))

  • 김만수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.63-67
    • /
    • 1994
  • A main property for fiber reinforced thermoplastic composite material in compression molding is the flow of fibers. This flow is so effective a long direction of acting force that this study examined for the inclined angel of 30$^{\circ}$, 45$^{\circ}$ and 6$^{\circ}$. Below the near softing temperature of plastic, the fiber has been fractured at a point so that the fiber strength is smaller then the local hydrostatic stress in the mold. It has been found that the position of fracture is changing accrding to the incling angle. In case of the above softing temperature, the larger the inclined is, the farther the flow of fiber move. Also the plastic flow has been progresed with the cicular are type.

  • PDF

Early-Age Properties of Polymer Fiber-Reinforced Concrete

  • Myers, Daniel;Kang, Thomas H.K.;Ramseyer, Chris
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.1
    • /
    • pp.9-14
    • /
    • 2008
  • The cracking problem in concrete is widespread and complex. This paper reviews the problem and focuses on those parts of the problem that are more readily solved. Polymer fibers are shown to have promise in several important areas of the cracking problem. To investigate one of these areas of the cracking problem more completely, an experimental research program focusing on the early-age properties of fibers was carried out. This study researched the properties of four polymer fibers; two of the fibers were macrofibers, and two were microfibers. Each fiber was tested at several dosage rates to identify optimum dosage levels. Early-age shrinkage, long-term shrinkage, compressive strength, and tensile strength were investigated. Long-term shrinkage and strength impacts from the polymer fibers were minimal; however, the polymer fibers were shown to have a great impact on early-age shrinkage and a moderate impact on early-age strength.

Effect of Textile Pattern on Mechanical and Impregnation Properties of Glass Fiber/Thermoplastic Composite (유리 섬유/열가소성 복합 재료의 기계적 및 함침 특성에 대한 직물 패턴의 영향)

  • Kim, Neul-Sae-Rom;Lee, Eun-Soo;Jang, Yeong-Jin;Kwon, Dong-Jun;Yang, Seong Baek;Yeom, Jung-Hyun
    • Composites Research
    • /
    • v.31 no.6
    • /
    • pp.317-322
    • /
    • 2018
  • In various industry, the composite is tried to be applied to products and thermoplastic based composite is in the spotlight because this composite can be recycled. The use of continuous fiber thermoplastic (CFT) method increased gradually than long fiber thermoplastic (LFT). In this study, tensile, flexural, and impact test of different array types of glass fiber (GF)/thermoplastic composites were performed to compare with GF array. Impregnation property between GF mat and thermoplastic was determined using computed tomography (CT). At CFT method, thermoplastic film is not wet into GF roving and many voids are appeared into composite. This phenomenon affects to decrease mechanical properties. Plain pattern GF mat was the best mechanical and impregnation properties that distance between two roving was set closely to $100{\mu}m$.

A New Optical Coupling Scheme from Laser Diodes to Single-Mode Fibers for Low Cost Telecommunication Modules

  • Shim, Jong-In;Kweon, Gyeong-il
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.80-82
    • /
    • 1998
  • A new fiber coupling scheme using thermally over-expanded core(TOEC) fiber was proposed and demonstrated. In the coupling experiment between 1.3${\mu}{\textrm}{m}$ FP-LD and the proposed TOEC fiber with a tapered hemispherical microlens. superior performances such as a long working distance, a high coupling efficiency, and large misalignment tolerances were verified experimentally.