• Title/Summary/Keyword: Log file

Search Result 159, Processing Time 0.025 seconds

Metaverse Artifact Analysis through the Roblox Platform Forensics (메타버스 플랫폼 Roblox 포렌식을 통한 아티팩트 분석)

  • Yiseul Choi;Jeongeun Cho;Eunbeen Lee;Hakkyong Kim;Seongmin Kim
    • Convergence Security Journal
    • /
    • v.23 no.3
    • /
    • pp.37-47
    • /
    • 2023
  • The growth of the metaverse has been accelerated by the increased demand for non-face-to-face interactions due to COVID-19 and advancements in technologies such as blockchain and NFTs. However, with the emergence of various metaverse platforms and the corresponding rise in users, criminal cases such as ransomware attacks, copyright infringements, and sexual offenses have occurred within the metaverse. Consequently, the need for artifacts that can be utilized as digital evidence within metaverse systems has increased. However, there is a lack of information about artifacts that can be used as digital evidence. Furthermore, metaverse security evaluation and forensic analysis are also insufficient, and the absence of attack scenarios and related guidelines makes forensics challenging. To address these issues, this paper presents artifacts that can be used for user behavior analysis and timeline analysis through dynamic analysis of Roblox, a representative metaverse gaming solution. Based on analyzing interrelationship between identified artifacts through memory forensics and log file analysis, this paper suggests the potential usability of artifacts in metaverse crime scenarios. Moreover, it proposes improvements by analyzing the current legal and regulatory aspects to address institutional deficiencies.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

Development of the Web-based Sports Biomechanics Class (웹기반 운동역학 수업 모형 개발)

  • Lee, Ki-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.307-318
    • /
    • 2002
  • To provide a guideline for the development of a web-based sport biomechanics class in undergraduate program, thirty web sites, searched via search engines in May 2002, were analyzed intensively. In terms of requirement of log-in, only one site of 30 sites required user name and password. Seventeen(57%) sites provided the lecture note, which had various file formats such as 59% if PDF, 29% of HTML, and 12% of PPT. Fourteen(47%) sites provided the assignment and grade information on web. Eleven(37%) sites provided various resource and links which were related in sports biomechanics. Only four(13%) sites provided discussion or online digitizing or kinematic analysis program. Based on above results, a guideline for the development of a virtual classroom for college level sport biomechanics. A web-based sport biomechanics class should be developed with consideration of several functions as follows; homepage design, lecture note, measurement of class attendance, collaborative research system, and web-based data collection and analysis software for biomechanics laboratory.

Measurement of Quality Parameters of Honey by Reflectance Spectra

  • Park, Chang-Hyun;Yang, Won-Jun;Sohn, Jae-Hyung;Kim, Jong-Hoon
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1530-1530
    • /
    • 2001
  • The objectives of this study were to develop models to predict quality parameters of Korean bee-honeys by visible and NIR spectroscopic technique. Two kinds of bee-honey fronl acacia and polyflower sources were tested in this study. The honeys were harvested in the spring of 2000 and stored in the storage facility at 20$^{\circ}C$ during experiments. Total of 394 samples of honey were analyzed. Reflectance spectra, moisture contents, ash, invert sugar, sucrose, F/G (fructose/glucose) ratio, HMF (hydroxymethyl furfural), and C12/C13 ratio of honeys were measured. The average values for the tested honeys were 19.9% of moisture contents, 0.12% of ash, 68.4% of invert sugar, 5.7% of sucrose, 1.27 of F/G(fructose/glucose) ratio, 14.4 mg/kg of HMF, and -19.1 of C12/C13 ratio. A spectrophotometer, equipped with a single-beam scanning monochromator (NIR Systems, Model 6500, USA) and a horizontal setup module, was used to collect reflectance data from honey. The reflectance spectra were measured in wavelength ranges of 400∼2,498 nm. with 2 nm of interval. Thirty-two repetitive scans were averaged, transformed to log(1/Reflectance), and then were stored in a microcomputer file, forming one spectrum per measurement. A sample cell and reflectance plate were made to hold honey samples constantly. Spectra of honey samples were divided into a calibration set and a validation set. The calibration set was used during model development, and the validation set was used to predict quality parameters from unknown spectra. The PLS(Partial Least Square) models were developed to predict the quality parameters of honeys. The first and the second derivatives of raw spectra were also used to develop the models with proper smoothing gap. The MSC (multiplicative scatter correction) and the SNV & Dtr.(standard normal variate and detranding) preprocessing were applied to all spectra to minimize sample-to-sample light scatter differences. The PLS models showed good relationships between predicted and measured quality parameters of honeys in the wavelength range of 1100∼2200 nm. However, the PLS analysis was not good enough to predict HMF of honeys.

  • PDF

An Action Information Management Method for Creating Adaptive NPC (적응형 NPC를 생성하는 행동 정보 관리 기법)

  • Kim, Na-Ra;Um, Ky-Hyun;Cho, Kyung-Eun
    • Journal of Korea Game Society
    • /
    • v.8 no.1
    • /
    • pp.103-113
    • /
    • 2008
  • Although people have had more opportunities to enjoy various types of game, most of players have felt less satisfaction with the games. This is the reason that since most Non-player Characters (NPCs) are simple and uniform, they have some limitations for competing with a variety of players. Thus, technologies for creating intelligent NPCs that can compete with each player at a similar level are required. In this paper, we present an action information management method for creating adaptive NPCs based on the algorithm for calculating their action efficiency. This algorithm is useful to the adaptation method for saving and controlling player-appropriate action. In our method, adaptive NPCs observe the actions of players and collect the relationship data between status and action. The efficiency value of the action data is calculated and data of similar status are grouped, and finally stored at the action database. The game system of NPC updates the action database and stores diverse actions. Then, NPC selects action with high efficiency value. We have tested our algorithm on an action game. A random test subject performed a one-on-one game against an adaptive NPC in real-time. As a result, the action dispositions of both the subject and NPC are analyzed in a log file to determine whether or not the disposition of the subject is similar to that of the NPC. The statistics of the diverse test results shows that NPCs become adaptive to players with error rate within less than 6%.

  • PDF

Utility Analysis on Activating Web-Based Course Support System by Faculty in Universities (웹기반 강의지원시스템에 대한 대학교수의 활용도분석)

  • Kim, Kyung-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.11
    • /
    • pp.221-232
    • /
    • 2009
  • To purpose of the study was to analyze faculty utility of Web-Based course support system in Universities. Data were collected from log file in server computer, 5,023 faculties and 12,733 courses offered at spring semester of 2009 in the Metropolitan area S, K, D universities were analyzed. Specifically, frequency and percentile of faculties and courses using course management system were analyzed. In addition, the frequencies and percentiles of courses using sub-functions of course management system were analyzed and X2 test used to examine the difference of frequencies of faculties and courses using course system at using announcement, providing instructional material, public bulletin board and free board. Results were as follows. The 62.28% of faculties and 50.3% of courses have used Web-Based course support system. The results of Subfunction utility analysis showed the highest use as 80.4%. in providing instructional material. However, the use of announcement functions and online discussion was more or less low. Results imply that most of faculties and course are using course management system as supplementary system of off-line instruction.

Customer Intangible Value in a Social Network (사회적 네트워크에서의 고객무형가치에 대한 연구)

  • Han, Sangman;Lee, Jieun
    • Asia Marketing Journal
    • /
    • v.10 no.4
    • /
    • pp.99-121
    • /
    • 2009
  • Social networks can be a powerful force in marketing because they provide new ways to market to young generation. Though many studies on evaluation of customer lifetime value have been conducted, it is not clear how to assess the value of members within social networks. The purpose of this study is to evaluate members based on customer intangible value as well as customer lifetime value. Customer network value in terms of the power and influence within a network is analyzed through network structure analysis. Using Cyworld log file data, this study have shown that high percentage of members are very influential in terms of spreading or withholding information even though their CLV is low. It is expected that the findings of this research contribute to understand the interactive behaviors of members within networks and to provide valuable implications on new product launching and customer management strategies to marketers.

  • PDF

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.