• Title/Summary/Keyword: Lock-in

Search Result 1,296, Processing Time 0.032 seconds

Structure Analysis for Damper stopper of Lock-up Clutch (록업 클러치의 댐퍼 스토퍼에 대한 구조해석)

  • Oh, Myung-Seok;Nam, Sang-Heon;Lee, Bong-Gu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.1865-1870
    • /
    • 2014
  • Torque converter is a complex turbomachine used to transfer power smoothly from an engine to a transmission by lock-up clutch. A torque converter consists of the hydrodynamic clutch device and the lock-up clutch device. The retaining plate and driven plate are part of the lock-up clutch. The lock-up clutch connects directly to achieve the improvement of efficiency and fuel consumption. In this paper, using structure analysis of stress distribution on the shape of the mechanical stopper on retaining plate. The shape of mechanical stopper has effect on the stress distribution of lock-up clutch.

An Experimental Research on the Flexural Behavior of Concrete Beams with Lock Joint Coupler Bars (커플러 이음 철근을 사용한 철근콘크리트 보의 휨 거동에 대한 실험적 연구)

  • Park, Sun-Kyu;Lee, Kwal;Ko, Won-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.197-204
    • /
    • 2000
  • Tensile strength (stress) of bar splice is important in the research of mechanical behavior of reinforced concrete structures-beam, column etc.- with bar splice. The purpose of this research is to evaluate the flexural behavior - deflection of beam specimens, strain of main bars - of reinforced concrete beam with Lock Joint Coupler. To make a comparative research, reinforced concrete beam specimens with normal deformed bar and lap splice are tested and analyzed. Test results, Comparing a deflection of three types flexural specimens, a flexural specimen with Lock Joint Coupler is 40% greater than the other flexural specimens. At the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 50% less, and vice versa, at the point of 14cm far from the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 9% larger than the strain of main bar(D29) which calculated using the classical flexure theory. A discords, between a deflection behavior of the flexural specimens and a strain of the main bar, are caused by the difference of strain between the lock joint coupler and main bar, near the lock joint coupler. So, additional research is need to verify as stated above discords.

  • PDF

The evaluation of effectiveness of 3DCA using vacuum bag(Vac-Lock) for patient immobilization device (3DCA제작을 통한 Vac-Lock 사용시 효율성향상에 대한 연구)

  • Lee YoungChul;Lee ChulBin;Kang NoHyun;Kim DongEuk;Lee JungYong;Jeong InPyo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.67-72
    • /
    • 2004
  • Purpose : Patient immobilization is crucial factor for radiation therapy. Generally, we have been used vacuum bag immobilization device(Vac-Lock) for whole body immobilization. In order to easily set up of vacuum bag(Vac-Lock), we made a 3DCA(3-Dimensional Conformal Accessary). The purpose of this study is evaluation of effectiveness of 3DCA using Vack-Lock for patient immobilization. Materials and Methods : We made 3DCA(3-Dimensional Conformal Accessary) tool of wooden boards. The reasons to choice of wooden boards are its easily handling nature and cheap expenses. Results : (1) We reduced man power from $5{\sim}6$persons to 1person to make immobilizations, (2) Shortened work time from 1hour to within 10minutes. (3) Avoid a collision to treatment gantry head. (4) Its shapes are smart and clean. Conclusion : We have made and used 3DCA(3-Dimensional Conformal Accessary) tool was very effective and convenience for the patients and users.

  • PDF

Quench Characteristics of Flux-Lock Type Superconducting Fault Current Limiter According to The Number of YBCO (YBCO의 직렬연결에 따른 자속구속형 초전도 한류기의 퀜치특성)

  • Lee Sang-Il;Park Hyoung-Min;Choi Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.329-333
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) depending on the number of the serial connection between the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting elements in series. The operation of the flux-lock type SFCL can be divided into the subtractive and the additive polarity windings depending on the winding directions between the primary and secondary coils. In this paper, the analyses of voltage, current, and resistance of superconducting elements in serial connection were performed to increase the power capacity of flux-lock type SFCL. The power burden was reduced through the simultaneous quenching between the superconducting elements. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

Simulation of Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL (3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성 시뮬레이션)

  • Lim, Sung-Hun;Park, Chung-Ryul;Han, Byoung-Sung;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.167-168
    • /
    • 2005
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-Tc superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF

NUMERICAL ANALYSIS OF THE FLOW AROUND A ROTARY OSCILLATING CIRCULAR CYLINDER USING UNSTEADY TWO DIMENSIONAL NAVIER-STOKES EQUATION (Navier-Stokes 식을 이용한 회전 진동하는 2차원 원형 실린더 주위 유동 해석)

  • Lee, M.K.;Kim, J.S.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.8-14
    • /
    • 2011
  • Although the geometry of circular cylinder is simple, the flow is complicate because of the flow separation and vortex shedding. In spite of many numerical and experimental researches, the flow around a circular cylinder has not been clarified even now. It has been known that the unsteady vortex shedding from a circular cylinder can vibrate and damage a structure. Lock-on phenomenon is very important in the flow around an oscillating circular cylinder. The lock-on phenomenon is that when the oscillation frequency of the circular cylinder is at or near the frequency of vortex shedding from a stationary cylinder, the vortex shedding synchronizes with the cylinder motion. This phenomenon can be recognized by the spectral analysis of the lift coefficient history. At the lock-on region the vortex is shedding by the modulated frequency to the body frequency. However, the vortex is shedding by the mixed frequencies of natural shedding and forced body frequency in the region of non-lock-on. In this paper, it was analyzed the relation between the frequency of rotary oscillating circular cylinder and the vortex shedding frequency.

Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL (3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성)

  • Lim, Sung-Hun;Han, Tae-Hee;Park, Hyoung-Min;Cho, Yong-Sun;Song, Jae-Joo;Choi, Myoung-Ho;Hwang, Jong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.112-113
    • /
    • 2006
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-$T_c$ superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF

Analysis on Fault Current Limiting Characteristics of a Flux-Lock Type HTSC Fault Current Limiter with Hysteresis Characteristic (히스테리시스 특성을 고려한 자속구속형 고온초전도 사고전류 제한기의 사고전류 제한특성 분석)

  • Lim, Sung-Hun;Choi, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.94-98
    • /
    • 2007
  • The fault current limiting characteristics of a flux-lock type superconducting fault current limiter (SFCL) considering hysteresis characteristics of a flux-lock reactor, which is an essential component of the flux-lock type SFCL, were investigated. In the normal state, the hysteresis loss of iron core in the flux-lock type SFCL does not happen due to its winding's structure. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the hysteresis curves together with the fault current level due to the inductance ratio between the primary and the secondary windings, the increase of the number of turns in the secondary winding of the flux-lock type SFCL made the fault current level increase. On the other hand, the saturation of iron core was prevented.

Durability Test and Test Jig Development of an Automotive Parking Lock Gear (자동차용 파킹 락 기어의 내구시험과 시험 지그 개발)

  • Mun, Hyun-Sik;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.104-109
    • /
    • 2018
  • Generally, the durability of the parking lock gear is evaluated through an endurance test for the entire transmission but no test standard exists for the durability test of one part of a parking lock gear. Therefore, in this study, the durability test standards of the parking lock gear were determined autonomously, and the durability performance test was conducted. A static fracture test was carried out to determine the yield strength of the parking lock gear, and a durability test condition was set to 60 % of the yield strength. The durability test of 1,000,000 times was conducted under the given conditions using a dedicated test jig manufactured for the test. Because the jig fractured during the static fracture test, finite element analysis for the jig was carried out and the jig was re-designed. The modified jig was manufactured and the durability test was carried out based on the test standard of autonomously. The basic data on the performance and endurance limit of the parking lock gear were obtained using these tests and analyses, and the basic data will be used as fundamental materials for the design and the development of the parking lock gear.

Analysis of Fault Current Limiting Characteristics According to Variation of Inductances in Separated Three-phase Flux-lock Type SFCL (분리된 삼상자속구속형 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Park, Chung-Ryul;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.522-525
    • /
    • 2009
  • We investigated the fault current characteristics of the separates three-phase flux-lock type superconducting fault current limiter(SFCL) according to the variation of inductances. The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core. And superconductor is series connected on secondary coil. Superconductor is using the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carried out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics of additive polarity winding was better than subtractive polarity winding and when the inductances of coil 2 was lower, resistances of YBCO CC was more generated.