• Title/Summary/Keyword: Lock system

Search Result 558, Processing Time 0.039 seconds

A Distributed Real-Time Concurrency Control Scheme using Transaction the Rise of Priority (트랜잭션 우선 순위 상승을 이용한 분산 실시간 병행수행제어 기법)

  • Lee, Jong-Sul;Shin, Jae-Ryong;Cho, Ki-Hyung;Yoo, Jae-Soo
    • Journal of KIISE:Databases
    • /
    • v.28 no.3
    • /
    • pp.484-493
    • /
    • 2001
  • As real-time database systems are extended to the distributed computing environment, the need to apply the existing real-time concurrency control schemes to the distributed computing environment has been made. In this paper we propose an efficient concurrency control scheme for distributed real-time database system. Our proposed scheme guarantees a transaction to commit at its maximum, reduces the restart of a transaction that is on the prepared commit phase, and minimizes the time of the lock holding. This is because it raises the priority of the transaction that is on the prepared commit phase in the distributed real-time computing environment. In addition, it reduces the waiting time of a transaction that owns borrowed data and improves the performance of the system, as a result of lending the data that the transaction with the raised priority holds. We compare the proposed scheme with DO2PL_PA(Distributed Optimistic Two-Phase Locking) and MIRROR(Managing Isolation in Replicated Real-time Object Repositories) protocol in terms of the arrival rate of transactions, the size of transactions, the write probability of transactions, and the replication degree of data in a firm-deadline real-time database system based on two-phase commit protocol. It is shown through the performance evaluation that our scheme outperforms the existing schemes.

  • PDF

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

Design of Video Encoder activating with variable clocks of CCDs for CCTV applications (CCTV용 CCD를 위한 가변 clock으로 동작되는 비디오 인코더의 설계)

  • Kim, Joo-Hyun;Ha, Joo-Young;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.80-87
    • /
    • 2006
  • SONY corporation preoccupies $80\%$ of a market of the CCD used in a CCTV system. The CCD of SONY have high duality which can not follow the progress of capability. But there are some problems which differ the clock frequency used in CCD from the frequency used in common video encoder. To get the result by using common video encoder, the system needs a scaler that could adjust image size and PLL that synchronizes CCD's with encoder's clock So, this paper proposes the video encoder that is activated at equal clock used in CCD without scaler and PLL. The encoder converts ITU-R BT.601 4:2:2 or ITU-R BT.656 inputs from various video sources into NTSC or PAL signals in CVBS. Due to variable clock, property of filters used in the encoder is automatically changed by clock and filters adopt multiplier-free structures to reduce hardware complexity. The hardware bit width of programmable digital filters for luminance and chrominance signals, along with other operating blocks, are carefully determined to produce hish-quality digital video signals of ${\pm}1$ LSB error or less. The proposed encoder is experimentally demonstrated by using the Altera Stratix EP1S80B953C6ES device.

An Essay on the Relationship between Standards and Technological Innovation (표준과 기술혁신의 연관성에 관한 소고)

  • Sung, Tae-Kyung
    • Management & Information Systems Review
    • /
    • v.29 no.4
    • /
    • pp.225-244
    • /
    • 2010
  • In the information society, characterized by knowledge and network economy, standards and standardization became a very important factor in determining the competitiveness of nations and firms. This paper defines the concept of standards and standardization and reconstructs the theory on the relationship between standards and technological innovation. The findings and policy implications are as follows. First, the effect of standards on technological innovation differs according to its function(compatibility, minimum quality, information, and variety reduction) and types(product-related and non-product). On the other hand, standards can impede technological innovation. Second, in terms of national innovation system(NIS), standards are an infra-technology, which is a public good. Therefore, government should decide the optimal level of investment on standards and standardization. Third, since standards foster firms' innovation over the all stages of business activities company, industry, and government should connect standardization activities with R&D, manufacturing, marketing, supply chain, and technology transfer, Fourth, standards play an important role in product innovation as well as process innovation. Based on these theoretical background and hypotheses, the empirical study of the Korean firms is needed.

  • PDF

User-Level Threads for the ARX Real-Time Operating System (ARX 실시간 운영체계를 위한 사용자 레벨 쓰레드)

  • Seo, Yang-Min;Park, Jung-Keun;Hong, Seong-Soo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10a
    • /
    • pp.65-67
    • /
    • 1998
  • 내장 실시간 시스템이 높은 우선순위의 비동기적 이벤트를 적시에 처리하면서 필수적으로 적은 비용의 선점 다중쓰레드를 지원해야한다. 사용자 레벨 쓰레드는 커널 레벨 쓰레드 보다 적은 비용의 유연한 추상적 기법들을 제공하지만, 기존의 실시간 시스템에서는 스케줄링과 시그날(signal) 처리가 단순하다는 이류로 커널 레벨 쓰레드가 선호 되어왔다. 본 논문에서는 내장 실시간 시스템에 적합한 새로운 사용자 레벨 다중 쓰레드 방식을 제안한다. 이 기법은 가상 쓰레드(virtual threads)와 개선된 스케줄링 이벤트 업콜(scheduling event upcall) 메카니즘을 기반으로 한다. 가상 쓰레드는 사용자 레벨 쓰레드에게 커널 레벨의 실행 환경을 제공할 수 있도록 사용자 레벨 쓰레드를 커널 레벨로 형상화한 것이다. 이 쓰레드는 필요에 의해 잠시동안 사용자 레벨 쓰레드에 묶이는 소동적인 존재이다. 스케줄링 이벤트 업콜 메카니즘은 쓰레드 블록킹과 타이머 만기와 같은 커널 이벤트를 유저 프로세서에게 전달할 수 있게 한다. 본 논문의 개선된 업콜 방식은 scheduler activation과 시그날과 같은 전통적인 업콜 구조에서 예측하기 힘든 요소들을 배제했다. 순간적인 시스템의 과부하 상황에서도 이벤트를 놓치지 않으면서 커널과 유저 프로세서의 비싼 동기화 작업들을 피할 수 있도록 하는 잠금(lock)이 필요 없는 이벤트 큐를 상용한다. 본 기법은 서울대학교 실시간 운영체계 실험실에서 구현한 ARX위에 완벽하게 구현되었다. ARX 사용자 레벨 쓰레드가 사용자 레벨 쓰레드의 장점을 손상하지 않으면서 솔라리스와 윈도즈98과 같은 상용 운영체제의 커널 쓰레드보다 성능이 우수함을 실험적 비교에 의해서 입증한다.분에서 uronic acid를 분리동정하였을 때 점미는 0.90%, 백미는 0.66%, 흑미는 1.8%로서 흑미에서 uronic acid 함량이 두 배 이상으로 나타났다. 흑미의 uronic acid 함량이 가장 많이 용출된 분획은 sodium hydroxide 부분으로서 hemicellulose구조가 polyuronic acid의 형태인 것으로 사료된다. 추출획분의 구성단당은 여러 곡물연구의 보고와 유사하게 glucose, arabinose, xylose 함량이 대체로 높게 나타났다. 점미가 수가용성분에서 goucose대비 용출함량이 고르게 나타나는 경향을 보였고 흑미는 알칼리가용분에서 glucose가 상당량(0.68%) 포함되고 있음을 보여주었고 arabinose(0.68%), xylose(0.05%)도 다른 종류에 비해서 다량 함유한 것으로 나타났다. 흑미는 총식이섬유 함량이 높고 pectic substances, hemicellulose, uronic acid 함량이 높아서 콜레스테롤 저하 등의 효과가 기대되며 고섬유식품으로서 조리 특성 연구가 필요한 것으로 사료된다.리하였다. 얻어진 소견(所見)은 다음과 같았다. 1. 모년령(母年齡), 임신회수(姙娠回數), 임신기간(姙娠其間), 출산시체중등(出産時體重等)의 제요인(諸要因)은 주산기사망(周産基死亡)에 대(對)하여 통계적(統計的)으로 유의(有意)한 영향을 미치고 있어 $25{\sim}29$세(歲)의 연령군에서, 2번째 임신과 2번째의 출산에서 그리고 만삭의 임신 기간에, 출산시체중(出産時體重) $3.50{\sim}3.99kg$사이의 아이에서 그 주산기사망률(周産基死亡率)이 각각 가장 낮았다. 2. 사산(死産)과 초생

  • PDF

The Effect on the Lower Limbs Joint as the Landing Height and Floor Pattern (착지 높이와 지면 형태가 하지 관절에 미치는 영향)

  • Kim, Eun-Kyong
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.437-447
    • /
    • 2011
  • In this study, the lower limbs joints were analyzed for features based on the biomechanical characteristics of landing techniques according to height and landing on the ground type (flats and downhill). In order to achieve the objectives of the study, changes were analyzed in detail contents such as the height and form of the first landing on the ground at different angles of joints, torso and legs, torso and legs of the difference in the range of angular motion of the joint, the maximum angular difference between joints, the lower limbs joints difference between the maximum moment and the difference between COM changes. The subjects in this study do not last six months did not experience joint injuries 10 males in 20 aged were tested. Experimental tools to analyze were the recording and video equipment. Samsung's SCH-650A model camera was used six units, and the 2 GRF-based AMTI were used BP400800 model. 6-unit-camera synchronized with LED (photo cell) and Line Lock system were used. the output from the camera and the ground reaction force based on the data to synchronize A/D Syc. box was used. To calculate the coordinates of three-dimensional space, $1m{\times}3m{\times}2m$ (X, Y, Z axis) to the size of the control points attached to the framework of 36 markers were used, and 29 where the body was taken by attaching a marker to the surface. Two kinds of land condition, 40cm and 60cm in height, and ground conditions in the form of two kinds of flat and downhill slopes ($10^{\circ}$) of the landing operation was performed and each subject's 3 mean two-way RM ANOVA in SPSS 18.0 was used and this time, all the significant level was set at a=.05. Consequently, analyzing the landing technique as land form and land on the ground, the changes of external environmental factors, and the lower limbs joints' function in the evaluation were significantly different from the slopes. Landing of the slop plane were more load on the joints than landing of plane. Especially, knee extensor moment compared to the two kinds of landing, slopes plane were approximately two times higher than flat plane, and it was statistical significance. Most of all not so much range of motion and angular velocity of the shock to reduce stress was important. In the further research, front landing as well as various direction of motion of kinetic, kinetic factors and EMG variables on lower limbs joints of the study in terms of injury-prevention-approach is going to be needed.

A PN-code Acquisition method Using Array Antenna Systems for CDMA2000 1x (CDMA2000 1x용 배열 안테나 시스템에서 PN 동기 획득 방법)

  • Jo, Hee-Nam;Yun, Yu-Suk;Choi, Seung-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.8 s.338
    • /
    • pp.33-40
    • /
    • 2005
  • This paper presents a structure of the searcher using a diversity in array antenna systems operating in the cdma2000 1x signal environments. The new technique exploits the fact that the In-phase and quadrature components of interferers can respectively be viewed as an independent gaussian noise at each antnna element in most practical cdma signal environments. The proposed PN acquisition scheme is a singles-dwell PN acquisition system consisting of two stages, that is, the searching stage and the verification stage. The searching stage independently correlates the receiver multiple signals with PN generator of each antenna element for obtaining the synchronous energy at the entire region. Then, the searching results of each antenna element are non-coherently combinind. The verification stage compares the searching energy with the optimal threshold, which is predesigned in the lock detector, and decides whether the acquisition is successful or fail. In this paper, we analyzed the effect of tile diversity order to determine the mean acquisition time. In general, it is known that the mean acquisition time significantly decrease as the number of antenna elements increases. But, as the diversity order goes up, the enhancement of the performance is saturated. Therefore, to decrease the mean acquisition time of the searcher, we must design the optimal array antenna systems by considering the operating SNR range of the receiver, the probability of detection $P_D$ and that of false alarm $P_{FA}$ . The Performance of the proposed PN acquisition scheme is analyzed in frequency selective Rayleigh fading channels. In this paper, the effect of the number of antenna elements on PN acquisition scheme is shown according to the probability of detection $P_D$ and that of false alarm $P_{FA}$.

Nondestructive Evaluation of Remanent Life of Turbine Rotor Steel by Measuring Reversible Magnetic Permeability (가역투자율 측정에 의한 터빈로터강의 비파괴적 잔여수명 평가)

  • Ryu, Kwon-Sang;Nahm, Seung-Hoon;Kim, Yong-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.315-321
    • /
    • 2003
  • The integrity of the turbine rotors can be assessed by measuring the material properties at service temperature. In order to evaluate the remanent life of turbine rotor steel nondestructively, a measurement system of reversible magnetic permeability using an alternating perturbing magnetic field was constructed. We present a new non-destructive method to evaluate the remanent life of 1Cr-1Mo-0.25V steel using the value of reversible magnetic permeability. This method is based on the existence of reversible magnetic permeability in the differential magnetization around the coercive field strength. We measured the first harmonics voltage induced in a coil using a lock-in amplifier tuned to an exciting frequency. The Results of reversible magnetic Permeability and Wickers hardness on the aged samples show that the peak interval of reversible magnetic permeability (PIRMP) and Vickers hardness decreases as aging time increases. A softening curve is obtained from the correlation between Vickers hardness and the PIRMP. This curve can be used as a non-destructive method to evaluate the remanent life of turbine rotor steel.

Wireless Energy and Data Transmission Using Inductive Coupling (유도결합방식에 의한 무선 에너지 및 데이터 전송)

  • Lee, Joon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.42-48
    • /
    • 2008
  • Bio-implantable devices such as heart pacers, gastric pacers and drug-delivery systems require power for carrying out their intended functions. These devices are usually powered through a battery implanted with the system or are wired to an external power source. This paper describes an inductive power transmission link, which was developed for an implantable stimulator for direct stimulation of denervated muscles. The carrier frequency is around 1MHz, the transmitter coil has a diameter of 46mm, and the implant coil is 46mm. Data transmission to the implant with amplitude shift keying (ASK) and back to the transmitter with passive telemetry can be added without major design changes. We chose the range of coil spacing (2 to 30mm) to care for lateral misalignment, as it occurs in practical use. If the transmitter coil has a well defined and reliable position in respect to the implant, a smaller working range might be sufficient. Under these conditions the link can be operated in fixed frequency mode, and reaches even higher efficiencies of up to 37%. The link transmits a current of 50 mA over a distance range of 2-15 mm with an efficiency of more than 20% in tracking frequency. The efficiency of the link was optimized with different approaches. A class E transmitter was used to minimize losses of the power stage. The geometry and material of the transmitter coil was optimized for maximum coupling. Phase lock techniques were used to achieve frequency tracking, keeping the transmitter optimally tuned at different coupling conditions caused by coil distance variations.

  • PDF

A Study on the Sounds and Vibrations of the Temporomandibular Joint using Electrovibratography (전자 진동술을 이용한 악관절의 잡음과 진동에 관한 연구)

  • Seok-Man Kang;Kyung-Soo Han;Min Shin
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.141-158
    • /
    • 1995
  • This study was performed to invetigate the relationship between clinical manifestations related to temporomandibular joint sounds and temporomandibular joint vibrations that occurred synchronously with sounds. There have been reported in many articles that joint sounds indicate internal joint pathology. Therefore, it is necessary to evaluate type and patterns of joint sounds, and radiographic changes of temporomandibular joint(TMJ) in order to diagnose and deal with the Temporomandibular Disorders(TMD). For this study 142 patients with TMDs were collected and they were examined by routine diagnostic procedure for TMDs. The author classified TMJ sounds clinically into 3 types : click, popping, and crepitus. Transcranial and panoramic radiographs were taken for observein bony changes of TMJ, and for observing vibrations of TMJ Sonopak of Biopak system was used. The obtained results were as follows : 1. Female subjects with crepitus were older than those with click or popping and their mean ages were about 45 years old. But in male subjects, there was no age difference. 2. For all subjects, mean value of maximal mouth opening were above 40mm, which are lower limit of normal vertical opening. But in subjects with L-type opening deviation, mouth opening capacity were about 36mm of range. 3. Symptom duration stated when patient presented first were slightly longer in subjects with crepitus but there were no statistical differences. And there were also no radiographic differences among 3 types of joint sounds in regard to symptom duration. 4. In subjects wih click, it might have been interpreted that 12% had closed lock, 12% had degenerative joint disease, and about 17% of he subjects had normal joints by Sonopak. 5. There were no significant relationships between subjective loudness of joint sounds and magnitude of joint vibrations. 6. The highest value of Integral and peak amplitude were observed in popping sounds and though it was not significant, value of peak frequency was highest in crepitus. 7. Amount of mandibular positional change were differed between click and crepitus on frontal plane, between click, crepitus and popping on horizontal plane in rotational movement, respectively. However, there no difference among them in translational movements.

  • PDF