• Title/Summary/Keyword: Locator

Search Result 201, Processing Time 0.021 seconds

Metadata format for Archives and Records Management (국가기록물관리를 위한 메타데이터)

  • Kim, Sung-hyuk;Ha, Jin-hyee
    • The Korean Journal of Archival Studies
    • /
    • no.5
    • /
    • pp.149-177
    • /
    • 2002
  • Metadata is a structured data that makes computer to understand web based data. Types of metadata are Dublin core, ONIX, and EBKS metadata in Korea. Dublin Core is well known among these metadata. Archive is a data, that is the result of ones or groups working process, which is reasonably maintained and stored. These archives are stored and maintained lawfully and suitably for efficient usages for the future. For efficiently managing these grant amount of archive, Finding Aids and Description are needed. Adoption Archives and Records Management system is inevitable in order to maintain organized and efficient data. Metadata helps governments data that is grant to organize in simple way. For maintaining and storing data efficiently, using metadata for Archives and Records Management is essential. Form this report, we will see the examples of using metadata of other country, such as GILS(Government Information Locator Service), AGLS(The Australian Government Locator Service), NZGLS(New Zealand Government Locator Service), Danish Dublin Core and e-GMS(e-Government Metadata Standard) and e-GMF(e-Government Metadata Framework).

Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length

  • Yoo, Jin Suk;Kwon, Kung-Rock;Noh, Kwantae;Lee, Hyeonjong;Paek, Janghyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.143-151
    • /
    • 2017
  • PURPOSE. The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. MATERIALS AND METHODS. Test model was created with epoxy resin. The strain gauges made a tight contact with implant surfaces. A universal testing machine was used to exert a vertical pressure on the mandibular implant overdenture and the strain rate of the implants was measured. RESULTS. Means and standard deviations of the maximum micro-deformation rates were determined. 1) Locator attachment: The implants on the working side generally showed higher strain than those on the non-working side. Tensile force was observed on the mesial surface of the implant on the working side, and the compressive force was applied to the buccal surface and on the surfaces of the implant on the non-working side. 2) Bar/clip attachment: The implants on the both non-working and working sides showed high strain; all surfaces except the mesial surface of the implant on the non-working side showed a compressive force. CONCLUSION. To minimize the strain on implants in mandibular implant overdentures, the attachment of the implant should be carefully selected and the denture base should be extended as much as possible.

Implementation and Evaluation of Dynamic and Distributed Mapping System in ID-LOC Separation Internet Architecture (ID-LOC 분리 기반 인터넷 구조에서 분산형 매핑 시스템의 구현 및 평가)

  • Kang, Hyung-Woo;Choi, Nak-Jung;Kim, Ji-In;Jung, Heeyoung;Koh, Seck-Joo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37B no.11
    • /
    • pp.984-992
    • /
    • 2012
  • In this paper, we discuss a new architecture of future Internet for mobile-oriented environments, named Mobile-Oriented Future Internet (MOFI). The MOFI architecture is designed with Host Identifier and Local Locator (HILL) for identifier and locator separation. Based on the HILL separation architecture, we propose a Dynamic and Distributed Mapping System (DDMS) for identifier-locator mapping control. In DDMS, the mapping control function is distributed onto each access router in the domain, which is different from the centralized approach using a central anchor. For validation of the proposed MOFI-DDMS architecture, we implemented the data delivery and mapping control functions using Linux platform. From the testbed experimental results, we see that the DDMS architecture can give better performance than the existing Proxy Mobile IP (PMIP) protocol in terms of data transmission throughput.

Mobile Oriented Future Internet (MOFI): OpenFlow-based Implementation and Testbed Experimentation over KOREN (모바일 중심 미래 인터넷: OpenFlow 기반 구현 및 KOREN 테스트베드 실험)

  • Kim, Ji-In;Jung, Heeyoung;Koh, Seok-Joo
    • Journal of KIISE:Information Networking
    • /
    • v.41 no.4
    • /
    • pp.167-176
    • /
    • 2014
  • In this paper, we discuss the implementation and experimentations of a new future Internet architecture for mobile-oriented environments, named Mobile Oriented Future Internet (MOFI). The MOFI architecture is featured by the host identifier and local locator for identifier-locator separation, Query-First Data Delivery (QFDD), and Distributed Mapping System (DMS) for identifier-locator mapping control. In the existing study on MOFI, we examined the intra-domain mobility control, the implementation of MOFI over Linux platform, and the performance analysis over the small-scale testbed. In this paper, we describe how to implement the MOFI architecture for inter-domain mobility control by using the OpenFlow and Click Modular Router platform. From the experimentations over the KOREN testbed, we can see that the MOFI scheme can give better performance than the existing Proxy Mobile IP scheme.

Fundamental Experiment for the Development of Water Pipeline Locator (상수도관로 위치탐사 장비개발을 위한 기초실험)

  • Park, Sang-Bong;Kim, Jin-Won;Oh, Kyeong-Seok;Kim, Min-Cheol;Koo, Ja-yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.253-261
    • /
    • 2016
  • A variety of methods for detecting the location of an underground water pipeline are being used across the world; the current main methods used in South Korea, however, have the problems of low precision and efficiency and the limitations in actual application. On this, this study developed locator capable of detecting the location of a water pipe by the use of an IMU sensor, and technology for using the extended karman filter to correct error in location detection and to plot the location on the coordinate system. This study carried out a tract test and a road test as basic experiments to measure the performance of the developed technology and equipment. As a result of the straight line, circular and ellipse track tests, the 1750 IMU sensor showed the average error of 0.08-0.11%; and thus it was found that the developed locator can detect a location precisely. As a result of the 859.6-m road test, it was found that the error was 0.31 m in case the moving rate of the sensor was 0.3-0.6 m/s; and thus it was judged that the equipment developed by this study can be applied to long-distance water pipes of over 1 km sufficiently. It is planned to evaluate its field applicability in the future through an actual pipe network pilot test, and it is expected that locator capable of detecting the location of a water pipe more precisely will be developed through research for the enhancement of accuracy in the algorithm of location detection.

Implant overdenture treatment using Locator attachment system on edentulous patient (무치악 환자에서 로케이터 부착장치를 이용한 임플란트 피개의치 수복 증례)

  • Kim, Soo-Yeop;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.176-183
    • /
    • 2014
  • Severely absorbed edentulous ridge cannot bear mechanical stress, causes undesired transformation of oral environment and makes patients difficult to adapt to dentures. Nowadays implant overdenture can be a treatment of choice in order to relieve patients' discomfort and improve stability and retention of the denture. Placement of implant on maxilla is difficult because of its bone quality and anatomic structure. It also has wide supportive tissue and convenience of border sealing, which provides sufficient support and stabilization with conventional complete denture. Mandible, on the other hand, is difficult to obtain sufficient support, retention and stabilization with conventional complete denture. Therefore, implant overdenture is recommended on mandible. Locator attachment has been improved for convenience of use and male parts of various retention enabled it to replace ball type attachment clinically. In this study, we restored maxillary arch with conventional denture, and mandibular arch with implant and tissue-supported overdenture and Locator attachment system.

AN IN VITRO EVALUATION OF THE ACCURACY OF ROOT ZX ELECTRONIC APEX LOCATOR (전자근관장측정기 Root ZX의 정확도에 관한 실험적 연구)

  • Kang, Dae-Hoon;Chung, Kwang-Hee;Yoon, Soo-Han;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.339-345
    • /
    • 1998
  • The purpose of this study was to evaluate the in vitro accuracy of Root ZX(Morita Co., Japan) which is the ratio type electronic apex locator. The 86 extracted human palatal roots of maxillary molar with fully formed apices were used. File lengths with the file tip just visible at the foramen were compared to those measured with Root ZX. For length measuring with Root ZX, saline test model with which the apical 1/3 of each root was submerged into normal saline were designed. The root canal lengths were determined with Root ZX and the radiographs were taken with a file in the canal. The distances from file tips of Root ZX lengths to apecies in radiographs also were measured with Profile projector PJ311(Mitutoyo Co., Japan). The results were as follows : 1. The root canal length determined with electronic apex locator was $0.78{\pm}0.53mm$ shorter than the length with visual measurement. 2. The file tip of Root ZX lengths was located at $0.85{\pm}0.49mm$ away from the apex in radiograph. 3. The accuracy of the Root ZX was 79.1% within 0.5mm of visual working length and 96.5% within 1.0mm.

  • PDF

IPv6 Networking with Subnet ID Deprecated

  • Kim, Young Hee;Kim, Dae Young;Park, Jong Won
    • Journal of Computing Science and Engineering
    • /
    • v.11 no.2
    • /
    • pp.49-57
    • /
    • 2017
  • This paper proposes a new IPv6 networking paradigm as a counter answer to the rationale for locator/identifier separation. Instead of involving separate number spaces each for node identifiers and locators, the context of the IP address as a node identifier alone is utilized and no additional locators are incorporated. That is, there are only node addresses and no locators, and location information is indirectly derived from neighbor relations between nodes. In order to accomplish this, no subnet IDs are utilized; the ID value is set to zero for all subnets. The paper details how to construct this paradigm through novel choice of operational policies in various IPv6 protocols and some trivial modifications. Especially, inherent provision of intra-domain node- as well as subnet-mobility by use of standard link-state intra-domain routing protocols is discussed. A number of important advantages of this paradigm over the canonical IPv6 networking and various known solutions of locator/identifier separation are discussed. Tailoring for multi-area domains and IPv4 is left for further study.

Development of Frequency Dependent Type Apex-Locator Improvementation by Auto-calibration Using Impedance Difference (주파수 의존형 전자근관장측정기 개발 및 임피던스차를 이용한 자동보정에 의한 성능향상)

  • Nam, K.C.;Kim, S.C.;Kim, D.W.;Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.399-402
    • /
    • 1997
  • It is important to find a accurate root canal length or successful endodontic therapy. By X-ray method takes a long time and difficult in a curved canal. After developed electronic apex locator has allowed to measure the root canal length with easy, in a short time also in a curved canal. But most electronic apex locators have the disadvantage which is too short reading or sometimes the measurement itself becomes impossible if there are electrolytes in the canal. To overcome this drawback, impedance ratio method has been developed. In this study, we have developed frequency dependent electronic apex locator to minimize the interference of electrolytes. And based on that also some error in clinic use, we added the other method. Difference of two signals which are used in calculation of impedance ratio was can be represent the status of root canal fluid. As a result, using impedance ratio method and auto-calibration by voltage difference method can reduce the measurement error.

  • PDF

Burst Locating Capability of the Korean Solar Radio Burst Locator (KSRBL)

  • Hwangbo, Jung-Eun;Bong, Su-Chan;Park, Sung-Hong;Lee, Dae-Young;Cho, Kyung-Suk;Lee, Jaejin;Park, Young-Deuk
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.1
    • /
    • pp.91-99
    • /
    • 2015
  • The Korean Solar Radio Burst Locator (KSRBL) is a solar radio spectrograph observing the broad frequency range from 0.245 to 18 GHz with the capability of locating wideband gyrosynchrotron bursts. Due to the characteristics of a spiral feed, the beam center varies in a spiral pattern with frequency, making a modulation pattern over the wideband spectrum. After a calibration process, we obtained dynamic spectra consistent with the Nobeyama Radio Polarimeter (NoRP). We compared and analyzed the locations of bursts observed by KSRBL with results from the Nobeyama Radioheliograph (NoRH) and Atmospheric Imaging Assembly (AIA). As a result, we found that the KSRBL provides the ability to locate flaring sources on the Sun within around 2'.