Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length |
Yoo, Jin Suk
(Private Practice)
Kwon, Kung-Rock (Department of Prosthodontics, School of Dentistry, Kyung Hee University) Noh, Kwantae (Department of Prosthodontics, School of Dentistry, Kyung Hee University) Lee, Hyeonjong (Department of Prosthodontics, School of Dentistry, Kyung Hee University) Paek, Janghyun (Department of Prosthodontics, School of Dentistry, Kyung Hee University) |
1 | Doundoulakis JH, Eckert SE, Lindquist CC, Jeffcoat MK. The implant-supported overdenture as an alternative to the complete mandibular denture. J Am Dent Assoc 2003;134: 1455-8. DOI |
2 | Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, Head T, Heydecke G, Lund JP, MacEntee M, Mericske-Stern R, Mojon P, Morais JA, Naert I, Payne AG, Penrod J, Stoker GT, Tawse-Smith A, Taylor TD, Thomason JM, Thomson WM, Wismeijer D. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology 2002;19:3-4. DOI |
3 | Burns DR. Mandibular implant overdenture treatment: consensus and controversy. J Prosthodont 2000;9:37-46. DOI |
4 | Jemt T, Carlsson L, Boss A, Jorneus L. In vivo load measurements on osseointegrated implants supporting fixed or removable prostheses: a comparative pilot study. Int J Oral Maxillofac Implants 1991;6:413-7. |
5 | Naert I, De Clercq M, Theuniers G, Schepers E. Overdentures supported by osseointegrated fixtures for the edentulous mandible: a 2.5-year report. Int J Oral Maxillofac Implants 1988;3:191-6. |
6 | Mericske-Stern R, Geering AH, Burgin WB, Graf H. Threedimensional force measurements on mandibular implants supporting overdentures. Int J Oral Maxillofac Implants 1992;7:185-94. |
7 | Setz J, Kramer A, Benzing U, Weber H. Complete dentures fixed on dental implants: chewing patterns and implant stress. Int J Oral Maxillofac Implants 1989;4:107-11. |
8 | Rangert B, Jemt T, Jorneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989;4: 241-7. |
9 | Tokuhisa M, Matsushita Y, Koyano K. In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability. Int J Prosthodont 2003;16:128-34. |
10 | el-Sheikh AM, Hobkirk JA. Force transmission in bar-retained implant-stabilised mandibular over-dentures: an in-vitro study. Eur J Prosthodont Restor Dent 2002;10:173-8. |
11 | Porter JA Jr, Petropoulos VC, Brunski JB. Comparison of load distribution for implant overdenture attachments. Int J Oral Maxillofac Implants 2002;17:651-62. |
12 | Heckmann SM, Winter W, Meyer M, Weber HP, Wichmann MG. Overdenture attachment selection and the loading of implant and denture-bearing area. Part 1: In vivo verification of stereolithographic model. Clin Oral Implants Res 2001;12: 617-23. DOI |
13 | Meijer HJ, Kuiper JH, Starmans FJ, Bosman F. Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. J Prosthet Dent 1992;68:96-102. DOI |
14 | Rosa LB, Bataglion C, Siessere S, Palinkas M, Mestriner W Jr, de Freitas O, de Rossi M, de Oliveira LF, Regalo SCH. Bite force and masticatory efficiency in individuals with different oral rehabilitations. Open J Stomatol 2012;2:21-6. DOI |
15 | Federick DR, Caputo AA. Effects of overdenture retention designs and implant orientations on load transfer characteristics. J Prosthet Dent 1996;76:624-32. DOI |
16 | Menicucci G, Lorenzetti M, Pera P, Preti G. Mandibular implant-retained overdenture: finite element analysis of two anchorage systems. Int J Oral Maxillofac Implants 1998;13:369-76. |
17 | Duyck J, Van Oosterwyck H, Vander Sloten J, De Cooman M, Puers R, Naert I. In vivo forces on oral implants supporting a mandibular overdenture: the influence of attachment system. Clin Oral Investig 1999;3:201-7. DOI |
18 | Meijer HJ, Starmans FJ, Steen WH, Bosman F. A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible. Arch Oral Biol 1993;38:491-6. DOI |
19 | Meijer HJ, Starmans FJ, Steen WH, Bosman F. A three-dimensional finite element study on two versus four implants in an edentulous mandible. Int J Prosthodont 1994;7:271-9. |
20 | Menicucci G, Lorenzetti M, Pera P, Preti G. Mandibular implant-retained overdenture: a clinical trial of two anchorage systems. Int J Oral Maxillofac Implants 1998;13:851-6. |
21 | Sadowsky SJ, Caputo AA. Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures. J Prosthet Dent 2000;84:327-34. DOI |
22 | Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent 2006;15:24-34. DOI |
![]() |