• Title/Summary/Keyword: Location determination function

Search Result 42, Processing Time 0.024 seconds

Identification of Female Specific Genes in the W Chromosome that are Expressed during Gonadal Differentiation in the Chicken

  • Rallabandi, Harikrishna Reddy;Yang, Hyeon;Jo, Yong Jin;Lee, Hwi Cheul;Byun, Sung June;Lee, Bo Ram
    • Korean Journal of Poultry Science
    • /
    • v.46 no.4
    • /
    • pp.287-296
    • /
    • 2019
  • Avian sex determination system involves the male ZZ and female ZW chromosomes. However, very few studies are reported the expression, functional role and importance of genes on the W chromosome because of its small and highly heterochromatic genomic regions. Recent studies demonstrated that the W chromosome may have critical roles in physiology, sex determination and subsequent sexual differentiation in chickens. Therefore, gene annotation, including describing the expression and function of genes in the chicken W chromosome, is needed. In this study, we have searched the W chromosome of chickens and selected a total of 36 genes to evaluated their specific expression in the testis and ovary at various developmental stages such as embryonic day 6 (E6), hatch and adult. Interestingly, out of 36 genes in chicken W chromosome, we have found seven female-specific expression at E6.5 day, indicating that they are functionally related to female chicken gonadal differentiation. In addition, we have identified the stage specific gene expression from the sex specific genes. Furthermore, we analyzed the relative location of genes in the chicken W chromosome. Collectively, these results will contribute molecular insights into the sexual determination, differentiation and female development based on the W chromosome.

Location Analysis of A Collective Consumption Facility with GIS: The Location of Gu-Office and Its Administrative District in Ulsan, South Korea (GIS기법을 이용한 도시공공서비스 시설의 입지분석 -울산시 구 관할구역과 구청입지를 중심으로-)

  • Cho, Sung-Ho;Park, Soon-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.2 no.1
    • /
    • pp.69-85
    • /
    • 1996
  • This research adoptes a spatial analysis function of the Geographic Information System[GIS] to analyze the location and the service district of a collective consumption facility, to discover the optimal location, and to redefine the service district. The location and spatial district of a collective consumption facility strongly influences the quality of life of residents. This research studies administrative offices and districts, especially Gu-offices in Ulsan. Ulsan would be raised to the status of Kwangyokshi in 1997; so that, the status of four Gus would be changed from a general administration into a self-governing administration. The summary of this research focuses on five significant points. First, the districts of four Gus were strongly required to be redefined to obtain the maximization of the degree of potential development as well as of the efficiency and equity of administring services. The spatial range of residents in a Gu was not in accord with its administrative district. The administrative districts of four Gus in Ulsan were not balanced in terms of area and population, and the high degree of disparity among Gus existed the efficiency and equality of a collective consumption service. Second, the current gu-offices were located based on security of land and accessibility of a main route; so, there was difficult to find the creteria and the principles of selections of the location of Gu offices. The social disparity of an administrative service existed in the accessibility into Gu-offices. Third, the administrative districts of Gus were redefined with spatial analysis tool of ARC/INFO. It was recommended that Ulsan maintain four Gus under the condition of five Kwangyokshi in South Korea. The redefined districts of administration reduced the disparity among four Gus in terms of area and population. improved the degree of harmony between the spatial range of residents of Gus and the administrative district of Gus, and increased the efficiency and equity of administrative service. Fourth, within the redefined adminis trative district of a Gu, the centroid reduced the maximum distance and mean distance; so, the efficiency and equity of public service provided by the Gu-office were improved. Last, the spatial analysis function of GIS helped to select the optimal location and to delineate the district of public service with more speedly and objectively. The function of spatial analysis of GIS was very useful to minimize the conflict in the determination of the location of a collective consumption facility and of the service district. To improve location analysis with GIS. non-spatial data base such as budget, thought of residents, and development policy and program, should be constructed.

  • PDF

Determination of Microviscosity and Location of 1,3-Di(1-pyrenyl) propane in Brain Membranes

  • Kang, Jung-Sook;Kang, In-Goo;Yun, Il
    • Archives of Pharmacal Research
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 1997
  • We determined the microviscosity of synaptosomal plasma membrane vesicles (SPMV) isolated from bovine cerebral cortex and liposomes of total lipids (SPMTL) and phospholipids (SPMPL) extracted from SPMV. Changes in the microviscosity induced by the range and rate of lateral diffusion were measured by the intramolecular excimerization of 1, 3-di(1-pyrenyl)propane (Py-3-Py). The microviscosity values of the direct probe environment in SPMV, SPMTL and SPMPL were 38.17, 31.11 and 27.64 cP, respectively, at$37^{\circ}C$and the activation energies $(E_a)$ of the excimer formation of Py-3-Py in SPMV, SPMTL and SPMPL were 8.236, 7.448 amd 7.025 kcal/mol, respectively. Probe location was measured by polarity and polarizability parameters of the probe Py-3-Py and probe analogues, pyrene, 1-pyrenenonanol and 1-pyrenemethyl-3${\beta}$-hydroxy-22, 23-bisnor-5-cholenate (PMC), incorporated into membranes or solubilized in reference solvents. There existed a good linear relationship between the first absorption peak of the $^1_a$ band and the polarizability parameter $(n^{2}-1)/(2n^{2}+1)$.The calculated refractive index values for SPMV, SPMTL and SPMPL were close to 1.50, which is higher than that of liquid paraffin (n=l.475). The probe location was also determined by using a polarity parameter $(f-1/2f^{I})$. Here f=$({\varepsilon}-1)/(2{\varepsilon}+1)$ is the dielectric constant function and $f^I=(n^2-1)/(2n^2+1)$ is the refractive index function. A correlation existed between the monomer fluorescence intensity ratio and the solvent polarity parameter. The probes incorporated in SPMV, SPMTL, and SPMPL report a polarity value close to that of 1-hexanol $({\varepsilon}=13.29)$. In conclusion, Py-3-Py is located completely inside the membrane, not in the very hydrophobic core, but displaced toward the polar head groups of phospholipid molecules, e.g., central methylene region of aliphatic chains of phospholipid molecules.

  • PDF

Variability in the Effective Spatial Range of the Population Centripetal Force of CBD (도심 인구구심력의 유효범위 변동성 측정)

  • Nam, Kwang-Woo;Kang, In-Joo;Im, Doo-Hyeon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.2
    • /
    • pp.120-131
    • /
    • 2009
  • This study measured the centripetal force and effective scope of the population spread from urban center and subcenters in order to diagnose the urban spatial structure of the formation of a multicentric city structure in Busan. The study analyzed the variability of the determination coefficient value (R square) with a negative exponential function derived from the population density model by extending the circular region into 5-km units. The aim of this study was to measure changes in the effective scope of the population centripetal force of the urban center and subcenter in 5-year intervals from 1995 to 2005 using census data. The explanatory adequacy of the population density function was examined with the bias of the function to calculate the distance error between the real location of the urban center and the optimal location, according to the population density function. To summarize the results, the value for the area of Jungangdong showed a continuous reduction, whereas Seomyeon (Bujeondong) maintained explanatory adequacy without a large change. As a whole, Busan was in the process of continuous diversification, in spite of its reduced population. Therefore, it appears necessary to strengthen the function of the urban center and subcenter and to supply adequate dwelling zones close to downtown to form a more efficient urban spatial structure. The results of the present study will be utilized as basic data for the formulation of a political approach to the efficient reorganization of spatial structure by correlating concrete spatial information with the population variability of Busan's urban center and subcenter.

  • PDF

Determination of Optimal Accelerometer Locations for Bridges using Frequency-Domain Hankel Matrix (주파수영역 Hankel matrix를 사용한 교량의 가속도센서 최적위치 결정)

  • Kang, Sungheon;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.27-34
    • /
    • 2016
  • A new algorithm for determining optimal accelerometer locations is proposed by using a frequency-domain Hankel matrix which is much simpler to construct than a time-domain Hankel matrix. The algorithm was examined through simulation studies by comparing the outcomes with those from other available methods. To compare and analyze the results from different methods, a dynamic analysis was carried out under seismic excitation and acceleration data were obtained at the selected optimal sensor locations. Vibrational amplitudes at the selected sensor locations were determined and those of all the other degrees of freedom were determined by using a spline function. MAC index of each method was calculated and compared to look at which method could determine more effective locations of accelerometers. The proposed frequency-domain Hankel matrix could determine reasonable selection of accelerometer locations compared with the others.

The Evaluation of UWB Wireless Communication Position Determination Function in an Enclosed Space for Fire Fighting (소방활동을 위한 밀폐공간 무선통신 측위성능 평가)

  • Kim, Dong-Hyun;Kim, Chung-Il
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.117-122
    • /
    • 2017
  • The absence of fire fighters' connection to communication can bring about increased loss of life due to errors and delays in rescue and actions and danger to their own safety. Therefore, when communication infrastructure has been destroyed in an enclosed space, it is necessary to set up an emergency wire or wireless telecommunication environment to fire fighting and to secure safer environment to deal with the disaster by checking the location of fire fighters. In this research, for the establishment communication environment in an enclosed inside using Ultra-Wide Band (UWB) wireless communication network, the performance of communication position determination of a single UWB communication module was evaluated regarding 6 kinds of indoor surroundings. When the communication distance in an indoor environment of each 6 channels bandwidth of UWB communication frequency was measured, the results were as follows: the open space (Ave. 15.5 m, Max. 20 m), the corridor (Ave. 17.33 m, Max 20 m), inside retaining home furnishings (Ave. 15.3 m, Max. 20 m), vertical stairs (Ave. 4.33 m, Max. 6 m), horizontal space with a closed fire door (Ave. 6.5 m, Max. 17 m). It was also found out that the communication function and the distance function were best in the frequency range from 6489.6 to 1081.6 MHz by 7 Ch. Accordingly, the establishment of communication environment in an enclosed space is judged to be possible when UWB communication module is set up at 20 m apart and multiple channels are used.

Internet of Things for in Home Health based Monitoring System: Modern Advances, Challenges and Future Directions

  • Omer Iqbal;Tayyeba Iftakhar;Saleem Zubair Ahmad
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.8
    • /
    • pp.191-204
    • /
    • 2024
  • IOT has carried out important function in converting the traditional fitness care corporation. With developing call for in population, traditional healthcare structures have reached their outmost functionality in presenting sufficient and as plenty as mark offerings. The worldwide is handling devastating developing antique population disaster and the right want for assisted-dwelling environments is turning into inevitable for senior citizens. There furthermore a determination by means of the use of way of countrywide healthcare organizations to increase crucial manual for individualized, right blanketed care to prevent and manipulate excessive coronial situations. Many tech orientated packages related to Health Monitoring have been delivered these days as taking advantage of net boom everywhere on globe, manner to improvements in cellular and in IOT generation. Such as optimized indoor networks insurance, community shape, and fairly-low device fee performances, advanced tool reliability, low device energy consumption, and hundreds higher unusual common usual performance in network safety and privacy. Studies have highlighted fantastic advantages of integrating IOT with health care location and as era is improving the rate also cannot be that terrific of a problem. However, many challenges in this new paradigm shift notwithstanding the fact that exist, that need to be addressed. So the out most purpose of this research paper is 3 essential departments: First, evaluation of key elements that drove the adoption and boom of the Internet of factors based totally domestic some distance off monitoring; Second, present fashionable improvement of IOT in home a long manner off monitoring shape and key building gadgets; Third, communicate future very last effects and distinct guidelines of such type a long way off monitoring packages going ahead. Such Research is a wonderful manner in advance now not outstanding in IOT Terminology but in standard fitness care location.

A Study on Determination of an Optimum Riparian Buffer Zone Based on Analytical Hierarchy Process (계층분석법을 이용한 적정 수변구역 결정에 관한 연구)

  • Han, Haejin;Park, Seok-Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.555-562
    • /
    • 2004
  • This paper presents the development and application of a riparian buffer zone design model(RBZDM). The model was developed as a decision-making tool for watershed management, by integrating geographic information system(GIS) and analytical hierarchy process(AHP) theory. Several factors for watershed management, such as pollution removal capacity, land aquisition cost, distribution of point and non-point pollution sources, and possibility of new pollution source location, were analyzed based on AHP theory. The vegetated buffer zone width was designed using GIS-based riparian buffer analysis. The developed model was applied to the Kyoungan Stream watershed, which is an important part of Paldang lake catchment area. The Kyoungan stream watershed was divided into sixteen subbasins. Six of them belong to the main stem, where the model was applied. Ten alternatives of buffer zone width and five hierarchial levels were designed. The relative importance and the relative preference were computed by pair-wise comparison of evaluation criteria given in hierarchial levels. The buffer zone width was determined by linear function of the given alternatives and relative preferences. From this study, it was determined that the six buffer zone widths of Kyoungan main stems would be 1,594, 1,744, 1,856, 1,782, 1,338, 1,780 meter, from upstream to downstream.

A Study on Strength Characteristics of Yieldable Steel Arch Supports (가축성 강재 지보의 강도특성에 관한 연구)

  • 김종우
    • Tunnel and Underground Space
    • /
    • v.8 no.4
    • /
    • pp.261-274
    • /
    • 1998
  • The brief results of laboratory and field tests of yieldable steel arches are represented. The test supports were fabricated with three U-sectional beams which are 25.8 kg/m of Glocken profile. The structural analyses of semi-circular and arch supports were conducted to find out shape factor of U beam to be 1.35 and the location of 2nd plastic hinges. Load capacity of arch supports under crown loading were examined as a function of leg length. Yieldable characheristics of test supports were investigated with various bolting torque of connection part. Determination method of bolting torque were also studied. Finally, test supports were installed in-situ with torque of 21 kg .m, which showed a typical yielding procedure.

  • PDF

Critical Shoulder Height of Raceway in Ball Bearing Considering Elastohydrodynamic Lubrication

  • Kim, Kyeongsoo;Kim, Taewan
    • Tribology and Lubricants
    • /
    • v.38 no.6
    • /
    • pp.281-286
    • /
    • 2022
  • In this study, the effects of Elasto-hydrodynamic lubrication pressure on the critical shoulder height of raceway in an angular contact ball bearing were investigated. Both 3D contact analyses using an influence function and the EHL analysis were conducted for the contact geometry between the ball and raceways. The pressure distributions by 3D contact analysis and EHL analysis for an example bearing were compared. The effect of ellipse truncation on the minimum film thickness also investigated from EHL analysis. The critical shoulder height in the dry contact and the EHL state were compared for various applied loads. It is shown that when the ellipse truncation occurs, the pressure spike for the EHL conjunction is higher than that for the dry contact, and its location moves more inward of the contact center. The steep pressure gradients would increase the flow rate, so in order to maintain flow continuity a significant reduction in film thickness and an abrupt rise in pressure occurs in the edge of shoulder. Significant reduction of the minimum film thickness occurs near the edge of shoulder. The critical shoulder heights in the EHL state are calculated as higher values compared with in the dry contact. This results shows that the determination of critical shoulder height by the EHL analysis is more proper.