• Title/Summary/Keyword: Location Measurement

Search Result 1,281, Processing Time 0.026 seconds

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

Design and Implementation of Quality Broker Architecture to Web Service Selection based on Autonomic Feedback (자율적 피드백 기반 웹 서비스 선정을 위한 품질 브로커 아키텍처의 설계 및 구현)

  • Seo, Young-Jun;Song, Young-Jae
    • The KIPS Transactions:PartD
    • /
    • v.15D no.2
    • /
    • pp.223-234
    • /
    • 2008
  • Recently the web service area provides the efficient integrated environment of the internal and external of corporation and enterprise that wants the introduction of it is increasing. Also the web service develops and the new business model appears, the domestic enterprise environment and e-business environment are changing caused by web service. The web service which provides the similar function increases, most the method which searches the suitable service in demand of the user is more considered seriously. When it needs to choose one among the similar web services, service consumer generally needs quality information of web service. The problem, however, is that the advertised QoS information of a web service is not always trustworthy. A service provider may publish inaccurate QoS information to attract more customers, or the published QoS information may be out of date. Allowing current customers to rate the QoS they receive from a web service, and making these ratings public, can provide new customers with valuable information on how to rank services. This paper suggests the agent-based quality broker architecture which helps to find a service providing the optimum quality that the consumer needs in a position of service consumer. It is able to solve problem which modify quality requirements of the consumer from providing the architecture it selects a web service to consumer dynamically. Namely, the consumer is able to search the service which provides the optimal quality criteria through UDDI browser which is connected in quality broker server. To quality criteria value decision of each service the user intervention is excluded the maximum. In the existing selection architecture, the objective evaluation was difficult in subjective class of service selecting of the consumer. But the proposal architecture is able to secure an objectivity with the quality criteria value decision where the agent monitors binding information in consumer location. Namely, it solves QoS information of service which provider does not provide with QoS information sharing which is caused by with feedback of consumer side agents.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

The characteristics of capital city plan of the BianLieng palace, the Dongjing Walled Town (東京城), the Northern song Dynasty (북송 동경 변량성의 조영과 특징)

  • Dashu, Qin
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.3
    • /
    • pp.114-159
    • /
    • 2012
  • The Northern Song Dynasty Period (北宋時代) was a drastic transitional era in all aspect of Chinese society including the politico-economic system, ideology and cultural trait. These changes that began in the late Tang (唐) Dynasty Period accomplished in the Northern Song Dynasty. In this phase, the fundamental change influenced in all institutional area; and among them, the capital city planning and its associating building technology to pile stone walls shows one of the significant change of those time. Based on the geographical factor, confluences of many rivers, the Kaifeing (開封) area where the BianLieng palace had developed as a political and economical centre since the Tang Dynasty when the Grand Canal was constructed. According to archaeological researches, the central city structure of Dongjing Walled Town was begun to plan in the late Tang Dynasty and formed in Five Dynasties. The fundamental functional change of city completed in the Midnorthern Song Dynasty. In spite of the relatively late beginning of archaeological investigations to Kaifeng Walled Town and Dongjing Walled Town due to unfavourable natural environment, excavations inaugurated since 1981 have achieved the significant investigations including the actual measurement and excavation to the outer wall, the preliminary excavation to the inner city area, the investigation and excavation to the royal palace of Song and the survey to the royal palace of King Zho in the Ming (明) Dynasty. These surveys have provide important data to reconstruct the 변량 palace, and elucidate the characteristics of city plan in the Dongjing Walled Town and the institutional change of capital city plan of the Northern Song Dynasty. The basic layout of Dongjing Walled Town reflect the realisation of ideality of the late Chinese medieval capital city structure that establish the commercial and economic centre based on the intensification of emperor's power by means of the organisation of ethical institution and the development of commercial economy. Firstly, the central place of the Kaifeng area is encircled with triple walls. This emphasise the authority of emperor located on the summit in the hierarchical ethic system succeeding to the main capital city plan of the late phase of ancient China. Secondly, the location of Dongjing Walled Town was decided by the transport network and the commercial function and defence function. Thirdly, this site shows the change of city structure and landscape of the Northern Song Dynasty. The closed Fengri (坊里: block) system transferred the open Jiexiang (街巷: road) system. Fourthly, the capital city was characterised by the free market trade and the diversification of market place. Fifthly, a convenient transport network in the Bian River, a centre of the Grand Canals, enabled to construct the Kaifeng Walled Town. Therefore, the Northern Song Dynasty continuously accomplished the developed water system as concerning about the utilisation of waterways after the construction of city.

Comparison of Particulate Matter and Ammonia Emission in Different Types of Laying Hen Poultry Houses during Spring (봄철 산란계사 사육형태별 미세먼지 및 암모니아 농도 비교)

  • Hong, Eui-Chul;Kang, Bo-Seok;Kang, Hwan-Ku;Jeon, Jin-Joo;You, Are-Sun;Kim, Hyun-Soo;Son, Jiseon;Kim, Hee-Jin;Yun, Yeon-Seo
    • Korean Journal of Poultry Science
    • /
    • v.48 no.3
    • /
    • pp.151-160
    • /
    • 2021
  • This study was conducted to determine the concentrations of particulate matter (PM) and NH3 emissions from different types of laying hens poultry houses during spring. The concentrations of PM and NH3 were measured three times (2-week intervals; March to May) in Floor-pen-, Aviary-, and Cage-type poultry houses. Overall, PM10 and PM2.5 concentrations were found to be low from 22:00 to 04:00. The PM10 and PM2.5 concentrations in Floor-pen and Cage houses were similar with no significant daily deviation. NH3 concentrations measured over 24 h at the center and end of Floor-pen house were relatively constant. Irrespective of measurement location, NH3 concentrations were the lowest in Floor-pen house. Moreover, NH3 concentrations were higher at the end of Floor-pen and Aviary houses than that at the center; however, lower concentrations of NH3 were detected at the end of Cage house. The concentrations of PM10 and PM2.5 around the poultry houses were 57.5 and 34.0 ㎍/m3, respectively, with the daily average PM10 and PM2.5 concentrations (4,730 and 447.7 ㎍/m3, respective) being the highest in Aviary house. The concentrations of NH3 at the center and end of Cage house were the highest at 12.0 and 9.31 ppm, respectively. Furthermore, in Cage house, the emission factor of NH3 was the lowest, whereas there was no significant difference on that of NH3. In conclusion, among the three types of poultry houses assessed, PM (PM10, PM2.5) concentrations were higher in Aviary house, whereas NH3 concentrations were higher in Cage house.

Usability assessment of thermoplastic Bolus for skin VMAT radiotherapy (피부 병변에 대한 VMAT 치료 시 열가소성 bolus의 유용성 평가: case review)

  • Kim, Min Soo;Kim, Joo Ho;Shin, Hyun Kyung;Cho, Min Seok;Park, Ga Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.85-92
    • /
    • 2020
  • Purpose: To find out the advantages of thermoplastic bolus compared to conventional bolus, which is mainly used in clinical practice, We evaluated Two cases in terms of dose and location reproducibility to assess Usability of thermoplastic Bolus for skin VMAT radiotherapy. Materials and Methods: Two patient's treated with left breast skin lesion were simulated using thermoplastic Bolus and planned with 2arc VMAT. the prescription dose was irradiated to 95% or more of the target volume. We evaluated The reproducibility of the bolus position by measuring the length of the air gap in the CBCT (Cone Beam CT) image. to evaluate dose reproducibility, we compared The dose distribution in the plan and CBCT and measured in vivo for patient 2. Results: The difference between the air gap in patient 1's simulation CT and the mean air gap (M1) during 10 treatments in the CBCT image was -0.42±1.24mm. In patient 2, the difference between the average air gap between the skin and the bolus (M2) during 14 treatments was -1.08±1.3mm, and the air gap between the bolus (M3) was 0.49±1.16. The difference in the dose distribution between Plan CT and CBCT was -1.38% for PTV1 D95 and 0.39% for SKIN (max) in patient 1. In patient 2, PTV1 D95 showed a difference of 0.63% and SKIN (max) -0.53%. The in vivo measurement showed a difference of -1.47% from the planned dose. Conclusion: thermoplastic Bolus is simpler and takes less time to manufacture compared to those produced by 3D printer. Also compared to conventional bolus, it has high reproducibility in the set-up side and stable results in terms of dose delivery.

Discrepancy and Correlation in the renal length between Kidney CT and 99mTc-DMSA Renal scan (신장 CT 검사와 99mTc-DMSA Renal Scan 검사에서 측정한 신장 길이의 차이 및 상관분석)

  • Jung, Woo-Young;Shim, Dong-Oh;Lee, Dong-Hun;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • Purpose This article studies the relationship between the length of a kidney measured by two scanning methods: Kidney Computed Tomography (CT) and 99mTc-Dimercaptosuccinic acid (DMSA) renal scan. Kidney CT provides a better anatomic assessment, while 99mTc-DMSA renal scan is superior in the kidney function test. Materials and Methods From January to December of 2019, two hundred patients who had Kidney CT and Tc99m-DMSA renal scan were chosen for this study. SPSS17.0 was selected for statistical analysis. Results Due to the effect of the breathing and resolution of 99mTc-DMSA renal scan, it showed the kidney's relatively longer length than the length of Kidney CT. For the same kidney, the length comparison among different brands' Gamma cameras was negligible. The length difference within the same age group did not show a noticeable discrepancy. However, there was a length difference between the radio technologists. Kidney CT and 99mTc-DMSA renal scan indicated a strong positive correlation between the length of the left and right kidney. Conclusion It is necessary to establish a standardized measurement method for measuring kidney length using 99mTc-DMSA renal scan. The kidney's functional changes and length changes are indications of Kidney diseases. Especially, pediatric patients tend to use 99mTc-DMSA renal scan for assessing the kidney's shape and the function to avoid potential radiation exposure during the Kidney CT. Therefore, it is significant to provide not only the kidney's functional information but also an anatomic analysis, including the kidney's size, length, and location through the 99mTc-DMSA renal scan.

Analysis of the Effect of Corner Points and Image Resolution in a Mechanical Test Combining Digital Image Processing and Mesh-free Method (디지털 이미지 처리와 강형식 기반의 무요소법을 융합한 시험법의 모서리 점과 이미지 해상도의 영향 분석)

  • Junwon Park;Yeon-Suk Jeong;Young-Cheol Yoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.1
    • /
    • pp.67-76
    • /
    • 2024
  • In this paper, we present a DIP-MLS testing method that combines digital image processing with a rigid body-based MLS differencing approach to measure mechanical variables and analyze the impact of target location and image resolution. This method assesses the displacement of the target attached to the sample through digital image processing and allocates this displacement to the node displacement of the MLS differencing method, which solely employs nodes to calculate mechanical variables such as stress and strain of the studied object. We propose an effective method to measure the displacement of the target's center of gravity using digital image processing. The calculation of mechanical variables through the MLS differencing method, incorporating image-based target displacement, facilitates easy computation of mechanical variables at arbitrary positions without constraints from meshes or grids. This is achieved by acquiring the accurate displacement history of the test specimen and utilizing the displacement of tracking points with low rigidity. The developed testing method was validated by comparing the measurement results of the sensor with those of the DIP-MLS testing method in a three-point bending test of a rubber beam. Additionally, numerical analysis results simulated only by the MLS differencing method were compared, confirming that the developed method accurately reproduces the actual test and shows good agreement with numerical analysis results before significant deformation. Furthermore, we analyzed the effects of boundary points by applying 46 tracking points, including corner points, to the DIP-MLS testing method. This was compared with using only the internal points of the target, determining the optimal image resolution for this testing method. Through this, we demonstrated that the developed method efficiently addresses the limitations of direct experiments or existing mesh-based simulations. It also suggests that digitalization of the experimental-simulation process is achievable to a considerable extent.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.