• Title/Summary/Keyword: Location Error

Search Result 1,239, Processing Time 0.031 seconds

EPC method for delamination assessment of basalt FRP pipe: electrodes number effect

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.1
    • /
    • pp.69-84
    • /
    • 2017
  • Delamination is the most common failure mode in layered composite materials. The author have found that the electrical potential change (EPC) technique using response surfaces method is very effective in assessment delamination in basalt fiber reinforced polymer (FRP) laminate composite pipe by using electrical capacitance sensor (ECS). In the present study, the effect of the electrodes number on the method is investigated using FEM analyses for delamination location/size detection by ANSYS and MATLAB, which are combined to simulate sensor characteristic. Three cases of electrodes number are analyzed here are eight, twelve and sixteen electrodes, afterwards, the delamination is introduced into between the three layers [$0^{\circ}/90^{\circ}/0^{\circ}$]s laminates pipe, split into eight, twelve and sixteen scenarios for cases of eight, twelve and sixteen electrodes respectively. Response surfaces are adopted as a tool for solving inverse problems to estimate delamination location/size from the measured EPC of all segments between electrodes. As a result, it was revealed that the estimation performances of delamination location/size depends on the electrodes number. For ECS, the high number of electrodes is required to obtain high estimation performances of delamination location/size. The illustrated results are in excellent agreement with solutions available in the literature, thus validating the accuracy and reliability of the proposed technique.

The USN Node Location Recognition and Monitoring System Based on Low Power (저전력 기반의 USN 단말 위치 인식 및 모니터링 시스템)

  • Song, Young-Jun;Kim, Dong-Woo;Shin, Dong-Jin;Ahn, Jae-Hyeong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.6
    • /
    • pp.11-17
    • /
    • 2008
  • This paper proposes the USN node location recognition method with low power, which is the modified centroid method. The conventional Zigbee node location recognition is used to the three RSSI values from three beacons, respectively. When a person move with node, the moving speed of USN node doesn't fast. Therefore, one among three positions used to the value that it is a previous value. This method doesn't large the error in terms of the exact position. Using hand-off method, we get about 30% power advantage than the conventional centroid method. And Our monitoring system add the function that it is possible to search for the node region by color.

Estimation of Person Height and 3D Location using Stereo Tracking System (스테레오 추적 시스템을 이용한 보행자 높이 및 3차원 위치 추정 기법)

  • Ko, Jung Hwan;Ahn, Sung Soo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.2
    • /
    • pp.95-104
    • /
    • 2012
  • In this paper, an estimation of person height and 3D location of a moving person by using the pan/tilt-embedded stereo tracking system is suggested and implemented. In the proposed system, face coordinates of a target person is detected from the sequential input stereo image pairs by using the YCbCr color model and phase-type correlation methods and then, using this data as well as the geometric information of the stereo tracking system, distance to the target from the stereo camera and 3-dimensional location information of a target person are extracted. Basing on these extracted data the pan/tilt system embedded in the stereo camera is controlled to adaptively track a moving person and as a result, moving trajectory of a target person can be obtained. From some experiments using 780 frames of the sequential stereo image pairs, it is analyzed that standard deviation of the position displacement of the target in the horizontal and vertical directions after tracking is kept to be very low value of 1.5, 0.42 for 780 frames on average, and error ratio between the measured and computed 3D coordinate values of the target is also kept to be very low value of 0.5% on average. These good experimental results suggest a possibility of implementation of a new stereo target tracking system having a high degree of accuracy and a very fast response time with this proposed algorithm.

A Study on the Registration and Reconstruction of the Land Boundary Location in Numerical Cadastre (수치지적에서 토지경계의 등록과 복원에 관한 연구)

  • 김욱남;박희주
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.1
    • /
    • pp.9-15
    • /
    • 1998
  • Numerical cadastral surveying method has advantages of higher accuracy and less individual error than planetable surveying method if we consider the result of surveying at the same area. Now in the areas where they use numerical cadastral records, coordinate is the basis when the boundary location is registered in numerical cadastral re-cords or is reconstructed on land surface, and this coordinate represents simply the absolute locational relationship with respect to origin point. But when we register the cadastral boundary location in cadastral or reconstruct it on land, relative relationship with respect to traverse point is more advisable basis than absolute relationship with respect to orgin point. This study contributes to the numerical cadastral surveying by discussing the problems to be improved that the principle of coordinate based boundary location registration and reconstruction has.

  • PDF

An Expery System for the Diagnosis of the Fault Type and Fault Loaction In the Distribution SCADA System (배전 SCADA 기능을 이용한 고장타입.고장위치 진단 전문가 시스템)

  • Go, Yun-Seok;Sin, Deok-Ho;Sin, Hyeon-Yong;Lee, Gi-Seo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.11
    • /
    • pp.1417-1423
    • /
    • 1999
  • Distribution system can experience the diverse events instantly and permanently. Also, it can experience high impedance fault or line drop under unbalanced situation, Accordingly, it is difficulty to identify the fault location because that data collected from distribution SCADA system may include uncertainty. This paper proposes an expert system, which can infer the faulted location the quickly and exactly for the diverse events in the distribution system. The expert system utilizes distribution SCADA function and collected data, especially, the monitoring mechanism for the normal open position switches is adopted newly in order to recognize the fault type exactly. Also, automated fault location diagnosis strategy is developed in order to minimize the spreading effect of fault obtained from the error of the system operator. The proposed strategy is implemented in C language. Especially, in order to prove the effectiveness of proposed expert system, the several scenario is simulated for the given model system. The real feeders are selected as model system for the simulation.

  • PDF

Application of a Continuous Wavelet Transform to the Impact Location Estimation in Plate Type Structures (연속웨이블렛변환을 이용한 평판구조물에서의 충격위치 추정)

  • Park, Jin-Ho;Lee, Jeong-Han;Park, Gee-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.311-316
    • /
    • 2004
  • For the location estimation in the conventional LPMS(Loose Parts Monitoring System), it is popular to employ a group delay among the acoustic sensors installed within a 3 ft range from the impact source. However, there exists inherent error in determining the arrival time differences of the generated wave group among the neighboring sensors. To overcome this problem in this study, the two dimensional approach has been proposed and applied to effectively estimate the arrival time differences by using a continuous wavelet transform which is one of the linear time-frequency analysis methods. The experiment has been performed to both the plate model and the real steam generator in a nuclear power plant. It is expected that the reliability of the location estimation could be enhanced when the proposed time-frequency method is introduced into the LPMS system.

  • PDF

A Study on Development of the GPIR system Receiver Using G-Files (G-File을 이용한 GPIR 시스템 수신기 개발)

  • Choi, Sang-Kyoon;Kim, Jae-Saeng
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.3
    • /
    • pp.336-342
    • /
    • 2010
  • GPIR(GPS Position Information Revision) system is a new concept of GPS system which utilizes database containing the location of taking a picture by the existing GPS, an angle between a camera and a subject and the location information of buildings and minimizes the GPS's own margin of error and there by provides the services, such as location-guiding via GPS and way-guiding via navigation in an exact and precision way more than before. GPIR system comprehends the location of taking photos via GPS information saved in G-files, searches database in the direction of taking a photo at a photo-taking position via location information and the photo-taking directional angle. And GPIR system corrects the GPS information searched to the location of a subject, again saves such information in a G-file and is ready for receiving more detailed location of the subject. This study explores into the design and development of a receiver which a GPIR user is able to utilize its system as well as the design of the receiver's prototypes.

Comparative Analysis of TOA and TDOA method for position estimation of mobile station (이동국 위치 추정을 위한 TOA와 TDOA방법의 비교 분석)

  • 윤현성;이창호;변건식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.3
    • /
    • pp.595-602
    • /
    • 2000
  • This paper is aimed at developing an location tracking system of mobile station based on currently available mobile communication network or mobile Phone and PCS(Personal Communication System). When the location tracking of mobile stations is in services, Emergency-119, all of crime investigation, effective urban traffic management and the safety protection of Alzheimer's patients can be available. In order to track the location of the mobile and base station, assumption in this paper is to use the statistic characteristics of LOS when modeling the standard noise in case that radio path is LNOS environment. The standard variation of the standard noise is $\pm150$. First, location is estimated by the positioning algorithms of TOA and TDOA and compared each other. Second, after canceling the standard noise by Kalman filter, location is estimated by the above two positioning algorithms. Finally, the location by the Kalman filter and two positioning algorithms is estimated by smoothing method. As a result, 2 dimensional average location error is imvoved by 51.2m in TOA and 34.8m in TDOA when Kalman filer and two positioning algorithms are used, compared with the two positioning algorithm used. And there is 3 more meter improvement after smoothing than Kalman filer and two positioning algorithms used.

  • PDF

Location Estimation Algorithm Based on AOA Using a RSSI Difference in Indoor Environment (실내 환경에서 RSSI 차이를 이용한 AOA 기반 위치 추정 알고리즘)

  • Jung, Young-Jin;Jeon, Min-Ho;Ahn, Jeong-Kil;Lee, Jung-Hoon;Oh, Chang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.6
    • /
    • pp.558-563
    • /
    • 2015
  • There have recently been various services that use indoor location estimation technologies. Representative methods of location estimation include fingerprinting and triangulation, but they lack accuracy. Various kinds of research which apply existing location estimation methods like AOA, TOA, and TDOA are being done to solve this problem. In this paper, we study the location estimation algorithm based on AOA using a RSSI difference in indoor environments. We assume that there is a single AP with four antennas, and estimate the angle of arrival based on the RSSI value to apply the AOA algorithm. To compensate for RSSI, we use a recursive averaging filter, and use the corrected RSSI and the Pythagorean theorem to estimate the angle of arrival. The results of the experiment, show an error of 18% because of the radiation pattern of the four non-directional antennas arranged at narrow intervals.

Design and Implementation of Robustness Distributed RTLS in Dense Environment (밀집 환경에 적합한 신뢰성 있는 분산형 RTLS 시스템의 설계 및 구현)

  • Jang, Hyun-Sung;Choi, Hoon;Jung, Yeon-Su;Baek, Yun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.287-295
    • /
    • 2010
  • RTLS used to track the location of object or person in real time. However, if there are a lot of tags and readers, the conventional single RTLS server may fail to estimate location of tags. And if the server cannot receive the tags signal due to pass-loss or NLOS from more than three readers, the server fail to estimate location of tags. In this paper, we propose a special reader which embeds RTLS location engine for distributed RTLS. And by using multi-directional antenna, alleviating multi-path effect and allowing estimate tag's location only using two readers. We also implement the system, we can reduce server packet 16times and get the all results of location estimate in single second. We achieved the location error within 1m.