• Title/Summary/Keyword: Local wetting

Search Result 22, Processing Time 0.025 seconds

Direct-contact heat transfer of single droplets in dispersed flow film boiling: Experiment and model assessment

  • Park, Junseok;Kim, Hyungdae
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2464-2476
    • /
    • 2021
  • Direct-contact heat transfer of a single saturated droplet upon colliding with a heated wall in the regime of film boiling was experimentally investigated using high-resolution infrared thermometry technique. This technique provides transient local wall heat flux distributions during the entire collision period. In addition, various physical parameters relevant to the mechanistic modelling of these phenomena can be measured. The obtained results show that when single droplets dynamically collide with a heated surface during film boiling above the Leidenfrost point temperature, typically determined by droplet collision dynamics without considering thermal interactions, small spots of high heat flux due to localized wetting during the collision appear as increasing Wen. A systematic comparison revealed that existing theoretical models do not consider these observed physical phenomena and have lacks in accurately predicting the amount of direct-contact heat transfer. The necessity of developing an improved model to account for the effects of local wetting during the direct-contact heat transfer process is emphasized.

Visualization Study on Microscale Wetting Dynamics of Water Droplets on Dry and Wet Hydrophilic Membranes

  • Park, Kyungjin;Kim, Seong Yeon;Hong, Jiwoo;Kim, Jong Hyun;Lim, Geunbae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.277-281
    • /
    • 2022
  • The wetting dynamics of water droplets dispensed on the surface of dry and wet hydrophilic membranes were investigated experimentally from a microscale point of view. By using a high-speed, white-beam x-ray microimaging (WXMI) synchrotron, consecutive images displaying the dynamic motions of the droplets were acquired. Through analyzing the characteristics observed, it was found that the dry hydrophilic membrane showed local hydrophobicity at a certain point during the absorption process with apparent contact angles greater than 90. While on the other hand, the apparent contact angles of a water droplet absorbing into the wet membrane remained less than 90 and showed total hydrophilicity. The observations and interpretation of characteristics that affect the contact, wetting, recoiling, and dynamic behaviors of droplets are significant for controlling liquid droplet impingement in a desired manner.

WIND DRIVEN RAIN IMPACT ON A TALL BUILDING FACADE

  • Kim, Jong-Dae;Oh, Jung-Keun;Park, Byong-Keun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.242-246
    • /
    • 2010
  • To determine the trajectories and the impact of rain drops on the facade of a tall building, a particle tracking method is employed form steady state simulation of turbulent flow around the building. The simulation is performed for the upper part of the building comprising a detailed louver system. Rain is trapped at relative high rates on the roof and the penthouse, with Local Intensity Factors (LIF's) of the order of 1. The upper parapets and upper floors get a fair amount of wetting with LIF's of the order of 0.6. The wetting decreases downwards reaching values of 0.2 to 0.25 at the level of the louver system.

  • PDF

Experimental Study on the Wall-Wetting Formation and Spray Characteristics of Gasoline Engine Injector (가솔린엔진 인젝터의 벽류 및 분무특성에 관한 실험적 연구)

  • Lee, Sung-Won;Lee, Sang-In;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.815-820
    • /
    • 2010
  • Fuel spray characteristics of the gasoline engine injector has been studied experimentally. Wall wetting fuel stream of the 4-hole and 12-hole injectors has been tested and measured with various installation angle and port masking shapes. Spray visualization has been performed to analyze spray formation, spray angle, and penetration length. Test result shows that wall wetting is greatly influenced by the induction air flow and injector installation angle. Wall wetting amount decreased as injector installation angle decreased. Masking decreased wall wetting amount by increasing local intake-air flow velocity due to the decreased section area. Spray visualization showed that the 12-hole injector has robust performance characteristics compared with the 4-hole injector.

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate (고온 강판의 분무냉각에 있어서 MHF 점에 관한 연구)

  • Kim, Yeung-Chan
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.175-180
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about $900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the experimental results show that the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

Behaviour of unsaturated tuff- calcareous sand mixture on drying-wetting and triaxial paths

  • Goual, Idriss;Goual, Mohamed Sayeh;Taibi, Said;Abou-Bekr, Nabil
    • Geomechanics and Engineering
    • /
    • v.3 no.4
    • /
    • pp.267-284
    • /
    • 2011
  • The aim of the paper is to study the hydro-mechanical behaviour of a tuff and calcareous sand mixture. A first experimental phase was carried out in order to find the optimal mixture. This showed that the material composed of 80% tuff and 20% calcareous sand provides the maximum mechanical strength. The second experimental phase concerns the study of the drying- wetting behaviour of the optimal mixture. Triaxial shear tests in saturated and unsaturated states at constant water content were carried out on samples initially compacted at the MPO. Experimental results let to deduce the parameters necessary for the prediction of the hydro-mechanical behaviour of pavement formulated from tuff and calcareous sand mixtures, related to moisture. This optimal mixture satisfies the regulation rules and hence constitutes a good local eco-material, abundantly available, for the conception of pavements.

Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate (고온 평판의 분무냉각에 있어서 MHF점에 관한 연구)

  • 김영찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.974-981
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about$ 900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

Shallow Failure Characteristics of Weathered Granite Soil Slope in accordance with the Rainfall Infiltration (강우침투에 따른 화강풍화토 사면의 얕은파괴 특성)

  • Kim, Sun-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2810-2818
    • /
    • 2009
  • In order to examine the characteristic of shallow failure in cut slopes composed of weathered granite soil, this study calculated critical permeability coefficient according to rainfall characteristic in Korea, performed stability analysis according to the representative physical properties of weathered granite soil distributed in Korea such as horizontal distance to the failure surface of cut slope, slope inclination, slope height, and the depth of wetting by rainfall, and analyzed the results. In the results of analyzing critical permeability coefficient, when the local rainfall characteristic was considered, the maximum critical permeability coefficient was $7.16{\times}10^{-4}cm/sec$. We judged that shallow failure according to wetting depth should be considered when rainfall below the critical rainfall intensity lasts longer than the minimum rainfall duration in cut slopes composed of weathered granite soil, which had a critical permeability coefficient lower than the maximum critical permeability coefficient. Furthermore, using simulated failure surface, this study could understand the characteristic of shallow failure in cut slopes based on the change in slope safety factor according to horizontal distance, wetting depth, and strength parameter.

Some Aspects of Experimental in-Tube Evaporation

  • Ha, Sam-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.537-546
    • /
    • 2000
  • The heat transfer characteristics of refrigerant-oil mixture for horizontal in-tube evaporator have been investigated experimentally. A smooth copper tube and a micro-fin tube with nominal 9.5 mm outer diameter and 1500 mm length were tested. For the pure refrigerant flow, the dependence of the axial heat transfer coefficient on quality was weak in the smooth tube, but in the micro-fin tube, the coefficients were 3 to 10 times greater as quality increases. Oil addition to pure refrigerant in the smooth tube altered the flow pattern dramatically at low mass fluxes, with a resultant enhancement of the wetting area by vigorous foaming. The heat transfer coefficients of the mixture for low and medium qualities were increased at low mass fluxes. In the micro-fin tube, however, the addition of oil deteriorates the local heat transfer performance for most of the quality range, except for low quality. The micro-fin tube consequently loses its advantage of high heat transfer performance for an oil fraction of 5%. Results are presented as plots of local heat transfer coefficient versus quality.

  • PDF