• 제목/요약/키워드: Local void

검색결과 72건 처리시간 0.028초

대형단조에서의 미세기공 압착해석을 위한 유한요소법의 Global/Local 기법

  • 박치용;영동열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.819-823
    • /
    • 1996
  • In the large steel ingosts, void defects exhibiting microvoid shapes are inevitably formed in the V-segregation zone of the ingots during solidification. In the hot open-die forging process, material properties are improved by eliminating internal porosity. The void size is practically very small as compared with the huge large ingot. Thus, for deformation analysis of a large ingot, a massive number of elements are needed in order to describe a void surface and to uniform mesh sturcture. In the present work the Global/Local scheme has been introduced in order to reduce the computational time and to easily generate the mesh system as a void module of local mesh for obtaining the accurate solution around a void. The procedure of the global- local method consists of two steps. In the first step global analysis is carried out which seeks a reasonably good solution with a cpurse mesh system without describing a void. Then, a local analysis is performed locally with a fine mesh system under the size-criterion of a local region. The computational time has been greatly reduced. Though the work it has been shown that large ingot forging incorporation small voids can be effectively analyzed by using the proposed Global/Local scheme.

  • PDF

수직사각 유로내에서의 국부적 기포계수 측정에 관한 연구 (A Study on the Measurement of Local Void Fraction)

  • B.J. Yun;Kim, K.H.;Park, G.C.;C.H. Chung
    • Nuclear Engineering and Technology
    • /
    • 제24권2호
    • /
    • pp.168-177
    • /
    • 1992
  • 이상유동 현상의 해석은 원자력 발전소의 각계통과 가압경수형 원자로의 안전성 분석, 각종 열 수력학적 현상의 해석 그리고 타 산업체의 필요성에 의해 그 연구의 중대성이 커지고 있다. 이러한 이상유동의 현상 해석에 있어서 국부적 영역에서의 기포계수 결정은 매우 중요하다. 본 연구에서는 이러한 이상유동시 국부적 기포계수의 측정을 위하여 원자로내 부수로를 모사한 수직사각 유로를 제작하였다. 또한 국부적 영역에서의 기포계수 측정에 적합한 것으로 알려진 전기탐침 및 그 부가회로를 제작하였으며, 완성된 탐침을 이용하여 실제 비등이 발생하는 실험용 유로내에서 국부적 기포계수의 측정을 시도하였다. 실험 결과 제작된 전기탐침 및 그부가회로의 타당성을 확인 할 수 있었다.

  • PDF

통계적 보이드율계측에 의한 수직상향이상류의 유동양식과 보이드분포 분석 (Analyses of the Flow Patterns and Void Distribution in Vertical Upward Two Phase Flow with the Statistical Void Fraction Measurement)

  • 손병진;김인석;이진
    • 대한설비공학회지:설비저널
    • /
    • 제15권3호
    • /
    • pp.283-291
    • /
    • 1986
  • An experimental study has been conducted to investigate characteristics of the flow patterns, its transitions and the mean local void fraction obtained from which the probe was traversed diametrically from center to wall of the test section in the vertical upward air-water flow for isothermal condition using the electrical conductivity probe. It has been shown that the probability density function of the mean local void fraction measured statistically from a Fast Fourier Transform becomes a criterion for the flow patterns and the mean local void fraction profile is a highly function of the flow patterns.

  • PDF

수직상향 이상류에서 동심원관 간극이 유동양식과 보이드분포에 미치는 영향 (Effects of Annular Gap Size on the Flow Pattern and Void Distribution in a Vertical Upward Two-Phase Flow)

  • 손병진;김인석;김문철
    • 대한설비공학회지:설비저널
    • /
    • 제16권4호
    • /
    • pp.383-391
    • /
    • 1987
  • An experimental investigation has been conducted to determine the flow pattern for two-component , two-phase mixtures which flow vertically upwards in concentric annuli based on the measurement for the local void fraction and the distribution of the local void fraction in various radial locations in the annular gap. The annular test section consists of a lucite outer tube whose inside diameter is 38mm and a stainless steel rod, The rod diameter is either :2mm,16mm or 20mm. It is demonstrated that the probability density function of the fluctuations in void fraction may be used as an flow pattern indicator and the local void fraction distribution depends on the flow pattern and radial location in the annular passage.

  • PDF

비국소형 구성식을 이용한 보이드 재료의 변형 국소화 거동의 해석(I) (Analysis of Deformation Localization of Void Material using Nolocal Constitutive Relation (I))

  • 김영석;최홍석;임성언
    • 소성∙가공
    • /
    • 제9권1호
    • /
    • pp.59-65
    • /
    • 2000
  • Most studies of failure analysis in ductile metals have been based on the classical plasticity theory using the local constitutive relations. These frequently yields a physically unrealistic solution, in which a numerical prediction of the onset of a deformation localization shows an inherent mesh-size sensitivity. A one way to remedy the spurious mesh sensitivity resulted in the unreasonable results is to incorporate the non-local plasticity into the simulation model, which introduce an internal (material) length-scale parameter into the classical constitutive relations. In this paper, a non-local version of the modified Gurson constitutive relation has been introduced into the finite element formulation of the simulation for plane strain compression of the visco elastic-plastic void material. By introducing the non-local constitutive relations we could successfully removed the inherent mesh-size sensitivity for the prediction of the deformation localization. The effects of non-local constitutive relation are discussed in terms of the load-stroke curve and the strain distributions accross the shear band.

  • PDF

Experimental Study on Two-Phase Flow Parameters of Subcoolet Boiling in Inclined Annulus

  • Lee, Tae-Ho;Kim, Moon-Oh;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.29-48
    • /
    • 1999
  • Local two-phase flow parameters of subcooled flow boiling in inclined annulus were measured to investigate the effect of inclination on the internal flow structure. Two-conductivity probe technique was applied to measure local gas phasic parameters, including void fraction, vapor bubble frequency, chord length, vapor bubble velocity and interfacial area concentration. Local liquid velocity was measured by Pilot tube. Experiments were conducted for three angles of inclination; 0$^{\circ}$(vertical), 30$^{\circ}$, 60$^{\circ}$. The system pressure was maintained at atmospheric pressure. The range of average void fraction was up to 10% and the average liquid superficial velocities were less than 1.3 m/sec. The results of experiments showed that the distributions of two-phase How parameters were influenced by the angle of channel inclination. Especially, the void fraction and chord length distributions were strongly affected by the increase of inclination angle, and flow pattern transition to slug flow was observed depending on the How conditions. The profiles of vapor velocity, liquid velocity and interfacial area concentration were found to be affected by the non-symmetric bubble size distribution in inclined channel. Using the measured distributions of local phasic parameters, an analysis for predicting average void fraction was performed based on the drift flux model and flowing volumetric concentration. And it was demonstrated that the average void fraction can be more appropriately presented in terms of flowing volumetric concentration.

  • PDF

원관내 수직상향 2상유동에서 고분자물질이 유동양식에 미치는 영향 (The Effect of Flow Patterns with Polymer Additivies From Two Phase Flow at Vertical up Ward in Circular Tube)

  • 김재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권4호
    • /
    • pp.505-514
    • /
    • 1998
  • Flow pattern of air-water two phase flow depends on the conditions of pressure void fraction and channel geometry. We classify the flow pattern by measuring the output signal of the conductivity probe. under the classified flow pattern we mount a visualization equipment on the test section and take pictures. We vary the concentration of pure solvent and polymer to measure local void fraction. We know that the maximum point position of local void fraction distribution move from the center of the pipe to the wall of the pipe as JSL increase when JSA is constant in two phase flow. But we find that the maximum point position of local void friction move from the wal of the pipe to the center of the pipe when polymer concentration increase.

  • PDF

수직동심환상관에서 반경방향 보이드율의 변동특성 (Fluctuation Characteristics of Radial Void Fraction in Vertical Concentric Annuli)

  • 손병진;김인석;김문철
    • 대한설비공학회지:설비저널
    • /
    • 제16권5호
    • /
    • pp.516-524
    • /
    • 1987
  • This paper presents experimental data of fluctuation characteristics of local void fraction of air-water two-phase flow which are associated with the flow pattern, annular gap size and radial location in vertical concentric annuli with coefficient of skewness and kurtosis. The annular gap widths are 13mm, 11mm, and 9mm for a 38m inner diameter as the lucite outer tube. A electrical conductivity probe was used to measure the local void fraction and traversed diametrically from inner wall to outer wall using radial increments of 2mm. It was shown that distribution of the coefficient of skewness and kurtosis, which is related that the one is the asymmetry and the other peakness of local void fraction distribution was influenced by flow pattern, annular gap size and radial location.

  • PDF

수직이상유에서 유동방향과 동심원관 간극이 유동양식과 보이드분포에 미치는 영향 (I) (Effects of Flow Diretion and Annular Gap Size on the Flow Pattern and Void Distribution in a Vertical Two-Phase Flow(I) - In Case of Upward Flow -)

  • 손병진;김인석;김문철
    • 대한기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.856-866
    • /
    • 1987
  • 본 연구에서는 동심원관에서 기-수 이상류가 상향과 하향유동을 하는 경우에 대하여 시간평균 국부보이드율을 계측하여 확률밀도함수를 구하고, 이들로부터 통계량 인 분산도, 비대칭도계수, 첨도계수를 계산하여, 이들 값과 유동양식을 관련시켜 유동 양식의 판별기준을 정량적으로 제시하는데 목적이 있다. 또한 환상간제과 간제의 반 경방향 입치 및 유동양식에 따르는 시간평균국부보이드율의 변동을 구명하는데도 목적 을 두어 일차적으로 상향유동 경우에 대한 연구결과를 보고한다.

Effect of local web buckling on the cyclic behavior of reduced web beam sections (RWBS)

  • Akrami, Vahid;Erfani, Saeed
    • Steel and Composite Structures
    • /
    • 제18권3호
    • /
    • pp.641-657
    • /
    • 2015
  • Application of reduced web beam section (RWBS) as a sacrificial fuse element has become a popular research field in recent years. Weakening of beam web in these connections may cause local web buckling around the opening area which can affect cyclic behavior of connection including: maximum load carrying capacity, strength degradation rate, dissipated energy, rotation capacity, etc. In this research, effect of local web buckling on the cyclic behavior of RWBS connections is investigated using finite element modeling (FEM). For this purpose, a T-shaped moment connection which has been tested under cyclic loading by another author is used as the reference model. Fracture initiation in models is simulated using Cyclic Void Growth Model (CVGM) which is based on micro-void growth and coalescence. Included in the results are: effect of opening corner radii, opening dimensions, beam web thickness and opening reinforcement. Based on the results, local web buckling around the opening area plays a significant role on the cyclic behavior of connection and hence any parameter affecting the local web buckling will affect entire connection behavior.